![Whirlpool GBS307PRSS Instructions Manual Download Page 6](http://html.mh-extra.com/html/whirlpool/gbs307prss/gbs307prss_instructions-manual_436033006.webp)
6
Make Electrical Connection
This oven is manufactured with a neutral (white) power supply
wire and a cabinet-connected bare grounding wire crimped
together.
1. Disconnect power.
2. Feed the flexible cable conduit from the oven through the
opening in the cabinet.
3. Remove junction box cover if present.
4. Connect the flexible cable conduit from the oven to the
junction box using a UL listed or CSA approved conduit
connector.
5. Tighten screws on conduit connector.
6. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
4-Wire Cable from Power Supply
IMPORTANT: Use the 4-wire cable from power supply where local
codes do not permit connecting the frame-ground conductor to
the neutral (white) junction box wire or when connecting to a
4-wire electrical system.
1. Connect the 2 black wires together using a UL listed wire nut.
2. Connect the 2 red wires together using a UL listed wire nut.
3. Separate the factory crimped green (or bare) and white oven
cable wires.
4. Connect the 2 white wires together using a UL listed wire nut.
5. Connect the green (or bare) ground wire from the oven cable
to the green (or bare) ground wire (in the junction box) using a
UL listed wire nut.
6. Replace junction box cover.
3-Wire Cable from Power Supply
IMPORTANT: Use the 3-wire cable from power supply where local
codes permit connecting the frame-ground conductor to the
neutral (white) junction box wire:
If your home has:
And you will be
connecting to:
Go to section:
4-wire direct
A fused
disconnect or
circuit breaker
box
4-wire Cable from
Power Supply
3-wire direct
A fused
disconnect or
circuit breaker
box
3-wire Cable from
Power Supply
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
(12.7 cm)
5"
1"
(12.7 cm)
3
¹⁄₂
"
(8.9 cm)
A. Cable from power supply
B. Red wires
C. Green (or bare) ground wires
D. 4-wire cable from oven
E. Junction box
F. White wires
G. UL listed wire nuts
H. Black wires
I. UL listed or CSA approved
conduit connector
A. Cable from power supply
B. Junction box
C. Red wires
D. White wire (from power supply)
E. White and green (or bare) oven
ground wires - factory crimped
F. 4-wire cable from oven
G. Black wires
H. UL listed wire nuts
I. UL listed or CSA approved
conduit connector
A
B
C
D
E
F
G
H
I
B
C
D
E
F
H
G
A
I