background image

6

4-Wire Cable from Power Supply

IMPORTANT: Use the 4-wire cable from power supply where local 
codes do not permit connecting the frame-ground conductor to 
the neutral (white) junction box wire or when connecting to a 4-
wire electrical system.

1. Connect the 2 black wires together using a UL listed wire nut.
2. Connect the 2 red wires together using a UL listed wire nut.
3. Separate the factory crimped green (or bare) and white oven 

cable wires.

4. Connect the 2 white wires together using a UL listed wire nut. 
5. Connect the green (or bare) ground wire from the oven cable 

to the green (or bare) ground wire (in the junction box) using a 
UL listed wire nut.

6. Replace junction box cover.

3-Wire Cable from Power Supply

IMPORTANT: Use the 3-wire cable from power supply where local 
codes permit connecting the frame-ground conductor to the 
neutral (white) junction box wire:

1. Connect the 2 black wires together using a UL listed wire nut.
2. Connect the 2 red wires together using a UL listed wire nut.
3. Connect the factory crimped white and green (or bare) ground 

wires of the oven cable to the white (neutral) wire in the 
junction box using a UL listed wire nut.

4. Install junction box cover.
5. Reconnect power.

A. Cable from power supply
B. Red wires

C. Green (or bare) ground wires
D. 4-wire cable from oven

E. Junction box

F. White wires

G. UL listed wire nuts

H. Black wires

I. UL listed or CSA approved 

conduit connector

A
B

C

D

E

F

G

H

I

A. Cable from power supply
B. Junction box

C. Red wires
D. White wire (from power supply)

E. White and green (or bare) oven 

ground wires - factory crimped 

F. 4-wire cable from oven

G. Black wires
H. UL listed wire nuts

I. UL listed or CSA approved 

conduit connector

B

C

D

E

F

H

G

A

I

Summary of Contents for GBD277PR

Page 1: ...ference Save installation instructions for local electrical inspector s use IMPORTANT Installateur Remettre les instructions d installation au propriétaire Propriétaire Conserver les instructions d installation pour référence ultérieure Conserver les instructions d installation pour consultation par l inspecteur local des installations électriques 8303648 You can be killed or seriously injured if ...

Page 2: ...port surface to pass the appliance cable through to the junction box NOTE For undercounter installation it is recommended that the junction box be located in the adjacent right or left cabinet If you are installing the junction box on rear wall behind oven the junction box must be recessed and located in the upper or lower right or left corner of the cabinet otherwise the oven will not fit into th...

Page 3: ...t door F 27 70 5 cm min cutout height A 25 64 5 cm max recessed width B 51 129 5 cm max overall height C 26 67 9 cm overall width D 23 58 4 cm max recessed depth E 49 125 7 cm recessed height A B C D E F C A B D E A 27 68 6 cm min cabinet width B 1 2 5 cm top of cutout to bottom of upper cabinet door C 14 37 5 cm bottom of cutout to floor D 25 64 8 cm cutout width E 1 3 8 cm min bottom of cutout t...

Page 4: ...hrough flexible armored or nonmetallic sheathed copper cable with grounding wire See Make Electrical Connection section Flexible armored cable from appliance should be connected directly to the junction box Do not cut the conduit Use the length of conduit provided A UL listed or CSA approved conduit connector must be provided If the house has aluminum wiring connect the aluminum wiring to the copp...

Page 5: ...n box cover if present 4 Connect the flexible cable conduit from the oven to the junction box using a UL listed or CSA approved conduit connector 5 Tighten screws on conduit connector 6 Complete installation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available Electrical Connection Options A Remove trim screw and pull out A If your home...

Page 6: ...m power supply where local codes permit connecting the frame ground conductor to the neutral white junction box wire 1 Connect the 2 black wires together using a UL listed wire nut 2 Connect the 2 red wires together using a UL listed wire nut 3 Connect the factory crimped white and green or bare ground wires of the oven cable to the white neutral wire in the junction box using a UL listed wire nut...

Page 7: ...fasten oven to cabinet using the screws 2 for single oven 4 for double oven provided Insert the screws through holes in mounting rails Do not overtighten screws 6 On some models the oven vent is taped to the side of the oven See following instructions to install a Insert the vent tabs B into slots A in the oven frame b With one screw C for each side of the vent fasten vent securely to the oven 7 S...

Page 8: ...he oven Use and Care Guide Check Operation of Single Oven 1 Turn power on PF should appear in the display 2 Press CUSTOM BROIL BROIL will appear in the display 3 Press START Make sure the oven door is closed and the ON light is shown in the display If oven s does not operate check the following Household fuse is intact and tight or circuit breaker has not tripped Electrical supply is connected See...

Page 9: ... non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de ...

Page 10: ...limentation jusqu au boîtier de connexion REMARQUE Pour l installation sous un plan de travail on recommande que le boîtier de connexion soit situé dans le placard adjacent à droite ou à gauche Dans le cas de l installation du boîtier de connexion sur le mur arrière derrière le four le boîtier de connexion devra être encastré et placé dans l angle inférieur ou supérieur du placard à gauche ou à dr...

Page 11: ...in F Hauteur ouverture 27 70 5 cm min A Largeur encastrement 25 64 5 cm max B Hauteur hors tout 51 129 5 cm max C Largeur hors tout 26 67 9 cm D Profondeur encastrement 23 58 4 cm max E Hauteur encastrement 49 125 7 cm A B C D E F C A B D E A Largeur placard 27 68 6 cm min B Distance entre sommet de l ouverture et porte de placard supérieur 1 2 5 cm C Distance entre plancher et bord inf de l ouver...

Page 12: ...électrique Le câble blindé flexible de l appareil doit être connecté directement dans le boîtier de connexion Ne pas couper le conduit Utiliser toute la longueur du conduit fourni L installateur doit fournir un connecteur de conduit homologation UL ou CSA Si le domicile est équipé d un câblage en aluminium le connecter au fil de cuivre en utilisant les connecteurs spécialement conçus et homologués...

Page 13: ...allation dans le placard 3 Le cas échéant enlever le couvercle du boîtier de connexion 4 Connecter le câble blindé flexible entre le four et le boîtier de connexion utiliser un connecteur de conduit homologation UL ou CSA 5 Serrer les vis sur le connecteur de conduit 6 Terminer l installation selon la configuration de raccordement électrique 4 conducteurs recommandé 3 conducteurs si un circuit à 4...

Page 14: ...sque le code local en vigueur permet le raccordement entre le conducteur de liaison à la terre du châssis et le conducteur neutre blanc dans le boîtier de connexion 1 Connecter ensemble les 2 connecteurs noirs avec un connecteur de fils homologation UL 2 Connecter ensemble les 2 connecteurs rouges avec un connecteur de fils homologation UL 3 Dans le boîtier de connexion connecter ensemble les cond...

Page 15: ... éléments du placard avec les vis fournies 2 pour un four simple 4 pour un four double Insérer les vis à travers les trous des rails de montage Ne pas serrer excessivement les vis 6 Sur certains modèles l évent du four est immobilisé avec du ruban adhésif sur le côté du four Pour l installation procéder selon les instructions suivantes a Insérer les onglets de l évent B dans les ouvertures A du ch...

Page 16: ...ien Vérification du fonctionnement du four simple 1 Mettre l appareil sous tension L afficheur devrait indiquer PF 2 Appuyer sur CUSTOM BROIL cuisson personnalisée au gril BROIL apparaît sur l affichage 3 Appuyer sur START mise en marche S assurer que la porte du four est fermée et que le témoin lumineux ON marche est allumé sur l affichage Si le s four s ne fonctionne nt pas contrôler ce qui suit...

Reviews: