Connect Vent System
1.
Install transition on top of hood (if removed for shipping)
with (2) 3.5 x 9.5 mm sheet metal screws.
For vented installations only:
1.
Fit vent system over transition piece.
2.
Measure from the bottom of the air deflector to the bottom
of the hood outlet. Cut the ductwork at the measured
dimension.
Wall
outlet
Wall
outlet
Roof outlet
3.
Seal connection with clamps.
4.
Check that back draft dampers work properly.
Install Range Hood
NOTE:
Remove protective film from range hood and metal filters.
1.
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
B
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2.
Remove the grease filter. See “Range Hood Care” section.
3.
Level the range hood and tighten upper mounting screws.
4.
Install (2) 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
For non-vented (recirculating) installation only:
1.
Assemble the air deflector with the duct cover bracket with
2 assembly screws provided with the Recirculation Kit.
2.
Measure from the bottom of the air deflector to the bottom
of the hood outlet.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
A
C
B
B
A. Vent cover bracket
B. Assembly screws
C. Deflector
X
A
C
D
B
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.