INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting 

installation. Read and follow the instructions provided 

with any tools listed here.

Tools Needed

 

Level

 

Drill with 1

1

/

4

" (3 cm), 

1

/

8

" (3.2 mm),,and 

3

/

16

" (4.8 mm) 

drill bits

 

Pencil

 

Wire stripper or utility knife

 

Tape measure or ruler

 

Pliers

 

Caulking gun and weatherproof caulking compound

 

Vent clamps

 

Jigsaw or keyhole saw

 

Flat-blade screwdriver

 

Metal snips

 

Phillips screwdriver

Parts Needed

 

Home power supply cable

 

1

/

2

" (12.7 mm) UL listed or CSA approved strain relief

 

3 UL listed wire connectors

For Vented Installations, You Will Also Need:

 

1 wall or roof cap

 

Metal vent system

For Non-Vented (Recirculating) Installations, 

You Will Also Need:

 

Recirculation Kit for non-vented (recirculating) installations 

only. See “Assistance or Service” section to order.

 

6" (15.2 cm) diameter round metal vent duct length required 

is determined by ceiling height.

Parts Supplied

Remove parts from packages. Check that all parts are included.

 

Hood canopy assembly with blower and LED lights installed

 

Vent transition with back draft dampers installed

 

Vent cover support bracket

 

Metal grease filter(s)

 

Mounting template

 

2-piece vent cover

 

2 - 2.9 x 6.5 mm screws (Phillips)

 

2 - 3.5 x 9.5 mm screws (Phillips)

 

6 - 5 x 45 mm mounting screws (#2 Phillips)

 

4 - 5.4 x 75 mm screws (Phillips) (for 10 x 60 mm 

wall anchors)

 

2 - 8 x 40 mm wall anchors (masonry)

 

4 - 10 x 60 mm wall anchors

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 

installer’s responsibility to comply with installation clearances 

specified on the model/serial/rating plate. The model/serial/

rating plate is located behind the left filter on the rear wall 

of the vent hood.
Canopy hood location should be away from strong draft areas, 

such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. 

Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with 

a maximum total rating of 60,000 BTUs or less.
Grounded electrical outlet is required. See “Electrical 

Requirements” section.
The canopy hood is factory set for venting through the roof or 

wall. For non-vented (recirculating) installation, see “For non-

vented (recirculating) installation only” in the “Connect Vent 

System” section. Recirculation Kit is available from your dealer 

or an authorized parts distributor. See “Assistance or Service” 

section to order.
All openings in ceiling and wall where canopy hood will be 

installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 

Manufactured Home Construction Safety Standards, Title 

24 CFR, Part 328 (formerly the Federal Standard for Mobile 

Home Construction and Safety, Title 24, HUD, Part 280) 

or when such standard is not applicable, the standard for 

Manufactured Home Installation 1982 (Manufactured Home 

Sites, Communities and Setups) ANSI A225.1/NFPA 501A, 

or latest edition, or with local codes.

Product Dimensions

8 /

16

"

(20.8 cm)

7 /

4

"

(18.3 cm)

*28

6

/

16

"(72 cm) min.

42 /

8

"(107 cm) max.

**28

6

/

16

"(72 cm) min.

38

3

/

16

"(97 cm) max.

14"

(35.6 cm)

19

11

/

16

"

(50 cm)

1 /

2

" (3.9 cm)

10 /

4

"

(26 cm)

30" (76 cm)

36" (91.2 cm)

 
* For non-vented (recirculating) installations
 ** For vented installations

Summary of Contents for EXTKIT18FS

Page 1: ...ite at www whirlpool ca HOTTE DE CUISINIÈRE À MONTAGE MURAL DE 30 ET 36 76 2 ET 91 4 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composer le 1 800 807 6777 ou visiter notre site Web à www whirlpool ca Table of Contents Table des matières 2 LIB0175705 W11549256A IMPORTANT READ AND SAVE THESE ISNTRUCTIONS FOR RESIDENTIAL USE ...

Page 2: ...ent électrique 24 Installation des cache conduits 25 Achever l installation 25 UTILISATION DE LA HOTTE 26 Commandes de la hotte de cuisinière 26 ENTRETIEN DE LA HOTTE 27 Nettoyage 27 SCHÉMA DE CÂBLAGE 28 ASSISTANCE OU SERVICE 29 Au Canada 29 Accessoires 29 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow Al...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Page 4: ...l the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Give...

Page 5: ...m and number of elbows should be kept to a minimum to provide efficient performance For the Most Efficient and Quiet Operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together Use clamps to seal all joints in the vent system The vent system must have a damper If the roof or wa...

Page 6: ...re is used it is recommended that a qualified electrician determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has alumin...

Page 7: ...the back of the screw head to slide range hood into place For wall anchors install the 10 x 60 mm wall anchors and install the 5 4 x 75 mm screws into the wall anchors Tighten until the wall anchors are secure Back the screws out 1 4 6 4 mm Vent Cover Support Bracket Installation Installations using telescoping upper and lower vent cover assembly 1 Position the vent cover bracket on wall about 1 8...

Page 8: ...lots C Lower mounting screws 2 Remove the grease filter See Range Hood Care section 3 Level the range hood and tighten upper mounting screws 4 Install 2 5 x 45 mm lower mounting screws and tighten Use the optional wall anchors if needed For non vented recirculating installation only 1 Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the Recirculation Kit ...

Page 9: ...home power supply to yellow green ground wire F in terminal box using UL listed wire connectors 8 Tighten strain relief screw 9 Install terminal box cover 10 Reconnect power InstallVent Covers NOTE Remove protective film from the vent covers 1 When using both upper and lower vent covers push lower cover down onto hood and lift upper cover to ceiling and install with 2 2 9 x 6 5 mm screws A C E C D...

Page 10: ... After 5 minutes the hood will slow to medium speed Timer The range hood can be set to automatically turn off after 5 minutes With the desired fan speed activated press the Delay off button The fan will run on the chosen speed for 5 minutes after 5 minutes the fan will turn off automatically Pressing the Delay off button will cancel the 5 minute timer LCD screen The LCD screen displays C Extractio...

Page 11: ...Push up on metal filter and release handle to latch into place 6 Repeat steps 1 5 for the other filter Non Vented recirculating Installation Filters NOTE The maximum BTUs if you use carbon filter is 60 000 If you use the hood with the carbon filters on and it does not decrease the BTUs the engine can fail or generate an unsafe act 1 Cover the grille that covers the blower motor with the charcoal f...

Page 12: ...YL BR M BK WH RD BU GR YL GN YL GN BR YL WH RD BK GR BU MOTOR SPECIFICATIONS POWER SUPPLY FREQUENCY 120 VAC 60 HZ 240 W MOTOR RESISTANCE Ω BLUE GREY BLUE RED BLUE WHITE 17 7 27 1 34 6 41 2 BLUE BLACK POWER ABSORTION K3 K1 K2 TR1 CN5 CN3 CN1 CN2 User Interface LED LED BK BU RD ...

Page 13: ...rns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada Customer eXperience Centre toll free 1 800 807 6777 or visit our website at www whirlpool ca Our Consultants Provide Assistance With Scheduling of Service Whirlpool designated service technicia...

Page 14: ...as de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiel...

Page 15: ...e et évacuer adéquatement les gaz veiller à acheminer l air aspiré par un conduit jusqu à l extérieur ne pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA ...

Page 16: ...0 mm Exigences d emplacement IMPORTANT Observer les dispositions de tous les codes et règlements en vigueur Confier l installation de la hotte à un technicien qualifié C est à l installateur qu incombe la responsabilité de respecter les distances de séparation spécifiées sur la plaque signalétique de l appareil La plaque signalétique de l appareil est située derrière le filtre de gauche sur la par...

Page 17: ...onds de hauteur supérieure un ensemble d extension de cache conduit en acier inoxydable peut être acheté auprès de votre revendeur ou d un distributeur de pièces autorisé Voir la section Assistance ou service pour commander L extension de cache conduit remplace la section supérieure de cache conduit fournie avec la hotte Exigences concernant l évacuation seulement pour un modèle avec décharge à l ...

Page 18: ...t considérablement la performance La sortie à l extérieur du circuit d évacuation peut se faire à travers le toit ou à travers un mur Pour la sortie à travers un mur on doit employer un raccord coudé 90 Décharge par l arrière Le raccord coudé à 90 peut être installé immédiatement au dessus de la hotte Installation sans décharge à l extérieur recyclage S il n est pas possible d évacuer les fumées e...

Page 19: ...A seulement 60 Hz 15 ampères protégé par fusible Si le domicile possède un câblage en aluminium suivre la procédure ci dessous Connecter le câblage en aluminium en utilisant des connecteurs et ou des outils spécialement conçus et homologués UL pour fixer le cuivre à l aluminium Suivre la procédure recommandée par le fabricant de connecteurs électriques Les raccordements aluminium cuivre doivent sa...

Page 20: ...ssaires ou utiliser quatre chevilles d ancrage de 10 x 60 mm et vis de 5 4 x 75 mm Retirer le gabarit 5 Pour bois percer des avant trous de 3 16 4 8 mm à tous les emplacements de pose des vis dans du bois Pour les chevilles d ancrage percer des trous de 7 16 10 mm à tous les emplacements des chevilles d ancrage 6 Pour bois installer les 2 vis de montage de 5 x 45 mm Laisser un espace de 1 4 6 4 mm...

Page 21: ...es de serrage 3 Vérifier que les clapets anti retour fonctionnent correctement Installation de la hotte REMARQUE Ôter le film protecteur de la hotte de cuisine et des filtres en métal 1 À deux personnes au moins suspendre la hotte aux 2 crochets de montage à travers les encoches de montage à l arrière de la hotte A B C A Vis de montage B Fentes de montage C Vis de fixation inférieures 2 Ôter le fi...

Page 22: ...e de traction 9 Installez le couvercle de la boîte à bornes 10 Rebranchez le courant Installation des cache conduits REMARQUE Ôter le film de protection des couvercles de ventilation 1 En cas d utilisation des sections supérieure et inférieure du cache conduit pousser la section inférieure vers le bas sur la hotte et soulever la section supérieure vers le plafond puis installer l ensemble avec 2 v...

Page 23: ...t activée la hotte sera activée à vitesse maximale pendant 5 minutes Après 5 minutes la hotte ralentira à vitesse moyenne Minuteur La hotte peut être réglée pour s éteindre automatiquement après 5 minutes Lorsque la vitesse de ventilation souhaitée est activée appuyez sur le bouton Delay off Le ventilateur fonctionnera à la vitesse choisie pendant 5 minutes après 5 minutes le ventilateur s éteindr...

Page 24: ... et relâcher la poignée pour l emboîter Filtres d installation sans décharge à l extérieur recyclage REMARQUE le BTU maximum si vous utilisez un filtre à charbon est de 60 000 Si vous utilisez la hotte avec les filtres à charbon allumés et que cela ne diminue pas les BTU le moteur peut tomber en panne ou générer un acte dangereux 1 Posez le filtre à charbon comme couverture de la grille qui protèg...

Page 25: ...M N BL R BU GRIS JA VE JA VE MAR JA BL R N GRIS BU CARACTERISTIQUES DU MOTEUR PUISSANCE NOMINALE 60 HZ 240 W BLEU NOIR ALIMENTATION 120 VCA FRÉQUENCE BLEU BLANC 41 2 BLEU ROUGE 34 6 BLEU GRIS 27 1 17 7 RÉSISTANCE DU MOTEUR Ω K3 K1 K2 TR1 CN5 CN3 CN1 CN2 Interface Utilisateur DEL DEL N BU R ...

Page 26: ...ada Caractéristiques et spécifications sur toute notre gamme d appareils électroménagers Références aux marchands locaux Consignes d utilisation et d entretien Vente d accessoires et de pièces de rechange Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez soumettre par écrit toute question ou préoccupation à Whirlpool Canada à l adresse suivante Whirlpool Brand Home Applia...

Page 27: ...27 ...

Page 28: ... 2021 Whirlpool Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés W11549256A 08 21 ...

Reviews: