background image

11

3. Connect ground wire (green or bare) of direct wire cable to 

external ground conductor screw. Tighten screw.

4. Place the hooked ends of the other direct wire cable wires 

under the outer terminal block screws (hooks facing right). 
Squeeze hooked ends together. Tighten screws.

5. Tighten strain relief screw.

6. Insert tab of terminal block cover into slot of dryer rear panel. 

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to 

“Venting Requirements.”

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground 
conductor to neutral wire.

1. Loosen or remove center silver-colored terminal block screw.

2. Connect neutral wire (white or center wire) of power supply 

cord to the center, silver-colored terminal screw of the 
terminal block. Tighten screw.

3. Connect the other wires to outer terminal block screws. 

Tighten screws.

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel. 

Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go to 

“Venting Requirements.”

3-wire connection: Direct wire

Use where local codes permit connecting cabinet-ground 
conductor to neutral wire.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer 
can be moved if needed. 

Strip 3

¹⁄₂

" (8.9 cm) of outer covering from end of cable. Strip 

insulation back 1" (2.5 cm). If using 3-wire cable with ground 
wire, cut bare wire even with outer covering. Shape ends of wires 
into a hook shape.

A. External ground conductor screw 
B. Ground wire (green or bare) of power supply cable

C. ¾" (1.9 cm) UL listed strain relief
D. Center silver-colored terminal block screw

E. Neutral ground wire 

F. Neutral wire (white or center wire)

A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug

C. Neutral prong
D. Spade terminals with up turned ends

E.

³⁄₄

" (1.9 cm) UL listed strain relief

F. Ring terminals

G. Neutral (white or center wire)

A

B

C

D

E

F

A

B

D

C

E

F

G

A. External ground conductor screw
B. Neutral ground wire

C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)

E.

³⁄₄

" (1.9 cm) UL listed strain relief

A

B

C

D

E

    1"

(2.5 cm)

    3

¹⁄₂

"

(8.9 cm)

Summary of Contents for Duet W10151592A

Page 1: ...RONIC ELECTRIC DRYER Use CareGuide For questions about features operation performance parts accessories or service call 1 800 253 1301 or visit our website at www whirlpool com Table of Contents 2 W10151592A ...

Page 2: ...Vacation and Moving Care 23 Changing the Drum Light 23 TROUBLESHOOTING 24 ASSISTANCE OR SERVICE 26 ACCESSORIES 26 WARRANTY 28 DRYER SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if...

Page 3: ...action that could cause a load to catch fire Do not dry articles that have been previously cleaned in washed in soaked in or spotted with gasoline dry cleaning solvents or other flammable or explosive substances as they give off vapors that could ignite or explode Do not allow children to play on or in the dryer Close supervision of children is necessary when the dryer is used near children Before...

Page 4: ...asher and dryer and wish to avoid having loose items fall behind your machines you may purchase a pair of washer dryer backguards These will reduce the chance of items falling behind the machines during operation To order call the dealer from whom you purchased your dryer or refer to the Assistance or Service section Ask for Part Number 8558694 White LocationRequirements You will need A location t...

Page 5: ... be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spacing should be considered on all sides of the dryer to reduce noise transfer For closet installation with a door minimum ventilation openings in the top and bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable Com...

Page 6: ...dware which is available for purchase from your dealer Special provisions must be made in mobile homes to introduce outside air into the dryer The opening such as a nearby window should be at least twice as large as the dryer exhaust opening ElectricalRequirements It is your responsibility To contact a qualified electrical installer To be sure that the electrical connection is adequate and in conf...

Page 7: ... m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL listed strain relief If your outlet looks like this 4 wire receptacle 14 30R Then choose a 4 wire power supply cord with ring or spade terminals and UL listed strain relief The 4 wire power supply cord at least 4 ft 1 22 m long must have four 10 gauge copper wires and match a 4 wire re...

Page 8: ...elief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock WARNING Fire Hazard Use 10 g...

Page 9: ...ional 3 wire connection section 4 wire connection Power supply cord IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit the use of 3 wire connections 1 Remove center silver colored terminal block screw A Removable conduit connector B Hole below terminal block opening C Strain relief threads A B C If your home has And you will be connecting to Go to Sectio...

Page 10: ... end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw as shown 1 Remove center silver colored terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and place the hooked end hook facing right of the neutral wire white or center wire of direct wire cable under the center scre...

Page 11: ...f dryer rear panel Secure cover with hold down screw 6 You have completed your electrical connection Now go to Venting Requirements 3 wire connection Direct wire Use where local codes permit connecting cabinet ground conductor to neutral wire Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 3 8 9 cm of outer covering from end of cable Strip insulation b...

Page 12: ... local codes do not permit connecting cabinet ground conductor to neutral wire 1 Remove center silver colored terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and the neutral wire white or center wire of power supply cord cable under center silver colored terminal block screw Tighten screw 3 Connect the other wires to outer terminal...

Page 13: ... metal vent For best drying performance rigid metal vents are recommended Rigid metal vent is recommended to avoid crushing and kinking Flexible metal vent Flexible metal vents are acceptable only if accessible for cleaning Flexible metal vent must be fully extended and supported when the dryer is in its final location Remove excess flexible metal vent to avoid sagging and kinking that may result ...

Page 14: ...r s instructions NOTE The following kits for close clearance alternate installations are available for purchase To order please see the Assistance or Service section A Dryer B Elbow C Wall D Exhaust hood E Clamps F Rigid metal or flexible metal vent G Vent length necessary to connect elbows H Exhaust outlet Improper venting can cause moisture and lint to collect indoors which may result in Moistur...

Page 15: ...equirements that will help to achieve the best drying performance Vent system chart NOTE Side and bottom exhaust installations have a 90º turn inside the dryer To determine maximum exhaust length add one 90º turn to the chart InstallVentSystem 1 Install exhaust hood Use caulking compound to seal exterior wall opening around exhaust hood 2 Connect vent to exhaust hood Vent must fit inside exhaust h...

Page 16: ...d If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check the dryer s final location Be sure the vent is not crushed or kinked 5 Check that the dryer is level See Level Dryer 6 For power supply cord installation plug into an outlet For direct wire installation reconnect power 7 Re...

Page 17: ...LEVEL to adjust how dry you want the load to be As the cycle runs the control senses the dryness of the load and adjusts the time automatically for the selected Dryness Level NOTE Most loads may be dried using Normal which is shown in boldface type on your control panel Normal is the energy preferred dryness level and will use the least energy The default dryness setting is Normal when an Auto Dry...

Page 18: ...l is not adjustable for Manual Cycles Pressing the Dryness Level button will cause the triple beep indicating that this option is not selectable While a Manual Cycle is running you can change the settings for Time Temperature the WRINKLE SHIELD feature and the cycle signals Press the PAUSE CANCEL key twice to stop the dryer and clear the settings allowing you to select another cycle StoppingYourDr...

Page 19: ... The Damp light indicates that the load has reached the damp dry level To be alerted when your load is approximately 80 dry you may use the Damp Dry Cycle Signal option See Damp Dry Cycle Signal in Additional Features section NOTE The Damp light is not used with manual cycles Cool Down The Cool Down light glows during the cool down part of the cycle Laundry is cooling down for ease in handling Don...

Page 20: ...llows by hand periodically during the cycle Dry item completely Foam rubber pillows are slow to dry NOTE Automatic Cycles are not available when using the Air Only setting AdditionalFeatures Drum Light Select Drum Light to turn on the light inside the dryer drum During a cycle if Drum Light is selected the drum light turns on and will remain on until DRUM LIGHT is pressed again the door is open an...

Page 21: ...selection will not be accepted Changing Cycles after pressing Start 1 Press PAUSE CANCEL twice This ends the current cycle 2 Select the desired cycle and options 3 Press and hold START The dryer starts at the beginning of the new cycle NOTE If you do not press Start within 5 minutes of selecting the cycle the dryer automatically shuts off Changing Modifiers and Options after pressing Start You can...

Page 22: ...set time to complete drying if needed NOTE You must remove drying rack for normal tumbling Do not use automatic cycles with the drying rack DRYER CARE CleaningtheDryerLocation Keep dryer area clear and free from items that would obstruct the flow of combustion and ventilation air CleaningtheLintScreen Every load cleaning The lint screen is located in the door opening of the dryer The control panel...

Page 23: ... items may discolor the dryer interior These stains are not harmful to your dryer and will not stain future loads of clothes Dry unstable dye items inside out to avoid transfer of dye RemovingAccumulatedLint From Inside the Dryer Cabinet Lint should be removed every 2 years or more often depending on dryer usage Cleaning should be done by a qualified person From the Exhaust Vent Lint should be rem...

Page 24: ...dryer Check the front and rear edges of the drum for small objects Clean out pockets before laundering Are the four legs installed and is the dryer level front to back and side to side The dryer may vibrate if not properly installed See the Installation Instructions Is the clothing knotted or balled up When balled up the load will bounce causing the dryer to vibrate Separate the load items and res...

Page 25: ... lint screen clogged Clean lint screen Check for air movement Stains on load or drum Was dryer fabric softener properly used Add dryer fabric softener sheets at the beginning of the cycle Fabric softener sheets added to a partially dried load can stain your garments Drum stains are caused by dyes in clothing usually blue jeans This will not transfer to other clothing Loads are wrinkled Was the loa...

Page 26: ...nies Whirlpool designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the Whirlpool designated service company in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concern...

Page 27: ...27 Notes ...

Page 28: ...as purchased DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMA...

Reviews: