24
“L2” Diagnostic Code (low or no line voltage condition):
The drum will turn, but there may be a problem with your home
power supply keeping the dryer’s heater from turning on. The
dryer will continue to run when this diagnostic code is present.
Press any key to clear the code from the display and return
to the estimated time remaining.
Try the following:
Check to see if a household fuse has blown or circuit breaker
has tripped. Electric dryers use two household fuses or
breakers. Replace the fuse or reset the circuit breaker.
In the U.S.A., confirm the power cord is properly installed.
Refer to “Electrical Connection” for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualified electrician.
“AF” (low airflow condition):
The dryer will continue to run when this diagnostic code is
present. Press any key to clear the code from the display and
return to the estimated time remaining.
Try the following:
Clean lint screen.
Check to see if the vent run from the dryer to the wall is
crushed or kinked.
Confirm the vent run from the dryer to the wall is free of lint
and debris.
Confirm the exterior vent exhaust hood is free of lint and debris.
Confirm your vent system falls withing the recommended
run length and number of elbows for the type of vent you are
using. Refer to “Plan Vent System” for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, have your entire home venting run
cleaned.
Dryer Results
Clothes are not drying satisfactorily, drying times are too
long, or load is too hot
Is the lint screen clogged with lint?
Lint screen should be cleaned before each load.
Is the exhaust vent or outside exhaust hood clogged with
lint, restricting air movement?
Run the dryer for 5-10 minutes. Hold your hand under the
outside exhaust hood to check air movement. If you do not
feel air movement, clean exhaust system of lint or replace
exhaust vent with heavy metal or flexible metal vent. See the
Installation Instructions.
Are fabric softener sheets blocking the grille?
Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length?
Check that the exhaust vent is not too long or has too many
turns. Long venting will increase drying times. See the
Installation Instructions.
Is the exhaust vent diameter the correct size?
Use 4" (102 mm) diameter vent material.
Is the dryer located in a room with temperature below
45ºF (7ºC)?
Proper operation of dryer cycles requires temperatures above
45ºF (7ºC).
Is the dryer located in a closet?
Closet doors must have ventilation openings at the top and
bottom of the door. The rear of the dryer requires 5" (127 mm)
of airspace, and the sides and front of the dryer require a
minimum of 1" (25 mm). See the Installation Instructions.
Has the Air Only modifier been selected?
Select the right temperature for the types of garments being
dried. See “Modifiers.”
Is the load too large and heavy to dry quickly?
Separate the load to tumble freely.
Cycle time too short
Is the automatic cycle ending early?
The load may not be contacting the sensor strips. Level the
dryer.
Change the dryness level setting on Automatic Cycles.
Increasing or decreasing the dryness level will change the
amount of drying time in a cycle.
Lint on load
Is the lint screen clogged?
Clean lint screen. Check for air movement.
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.