Remove
Before removing air conditioner to the other place, you should
contact the seller firstly.
Then it must be done under the direction of the professional
technician.
Noise
Electric wiring
Install in a location where is firm enough to avoid the enlargement of noise
and vibration.
Don’t put anything in front of the outlet of
the
unit to avoid increasing
noise.
Be sure that hot air or noise will not inconvenience neighbors.
Please contact the seller as soon as there is strange noise during operation.
Please use the safety support.
8
Installation Instruction
Must connect with ground reliably.
The exclusive circuit must be used. But removable socket can’t be used because poor
contact of it can cause over heat or fire.
Don’t pull the power cord strongly.
In fixed circuit, there must be electricity leakage protection switch and leakage current
is less than 30mA.
Connecting method between air conditioners and power cord and interconnecting
method of each individual element with one another should accord with wiring
diagram on the unit.
The air conditioner should be installed in accordance with national wiring regulations.
An all-pole disconnection switch having a contact separation of at least 3mm in all
poles should be connected in fixed wiring.
Air switch (thermal-magnetic breaker) should be installed in the circuit.
If the supply cord is damaged, it must be replaced by the manufacturer or your
dealer or a qualified person to avoid a hazard.
All the
electrical work must be done according to the local wiring regulations.