S E R V I C E
Whirlpool Europe
12.12.1996 / Page 3
Customer Service
Doc. No: 4812 712 11769
Technical data
Program timer
Typ
Hybridtimer with integrated
electronic
Fab.
Eaton EC 4475
Nominal voltage
230
V
Frequency
50
Hz
Total positions
60
Programm positions
Pre wash
pos.
01 - 09
Main wash
pos.
10 - 31
Rinse
pos.
32 - 49
Spin
pos.
50 - 55
Safety position
pos.
56 - 58
Stop
pos.
59 - 60
Ambient temperature
to 70 ˚C
Storage temperature
to 85 ˚C
Output
motor reversing
A9 - A10
>40 V
pump
DP2.1 - DP.2.2 230 V
doorlock
DL3.1 - DL3.3
230 V
pressostat
A4 - A10
230 V
- empty
A2 - A10
230 V
- full
A3 - A10
230 V
aquastop
Aq2.2 - A10
230 V
- pumping step
Aq2.1 - A10
230 V
valve
>170 V
Motor
Typ
MCA 52/64 - 148/t.f. WHEO
i = 1 :13,5
Resistance
contacts
6 - 7
68,70
Ω ±
7%
4 - 5
2,15
Ω ±
7%
2 - 3
1,46
Ω ±
7%
1 - 3
0,65
Ω ±
7%
Radio interference supression
Condenser Friburg
Typ
FA 26
Nominal voltage
230
V
Nominal capacity
0,68
µ
FX2+2x0,022nFY
Nominal inductances
2 x 1
µ
H
Nominal resistance
470
K
Ω
Temperature selector switch
Positions
7
Nominal voltage
5
V
Value of resistors
1-2-3
internal shunt
4-6
internal shunt
5-6
Pos. 1 0
Ω
Pos. 2 0,68 k
Ω±
5%
Pos. 3 1,10 k
Ω±
5%
Pos. 4 1,80 k
Ω±
5%
Pos. 5 2,70 k
Ω±
5%
Pos. 6 3,60 k
Ω±
5%
Pos. 7 4,70 k
Ω±
5%
Spin selector switch
Positions
7
Nominal voltage
5
V
Value of resistors
1-2-3
internal shunt
4-6
internal shunt
5-6
Pos. 1 0
Ω
Pos. 2 0,68 k
Ω±
5%
Pos. 3 1,10 k
Ω±
5%
Pos. 4 1,80 k
Ω±
5%
Pos. 5 2,70 k
Ω±
5%
Pos. 6 3,60 k
Ω±
5%
Pos. 7 4,70 k
Ω±
5%
Push botton switch
Start stop
SST
Pre wash
SPW
Rinse hold
SRS
Rapid
SR
Eco
SEC
1/2 load
SHL
Intensive rinse
SRI