background image

ELECTRICAL CONNECTION

IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate.

ASSEMBLY

ADJUSTMENT TO DIFFERENT TYPES OF GAS

If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label 
on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.

Use pressure regulators suitable for the gas pressure indicated in the Instruction.

The gas nozzles must be changed by After Sales Service or a qualified technician.

Nozzles not supplied with the appliance must be ordered from After Sales Service.

Adjust the minimum setting of the taps.

NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will 
go.
IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for 
the replacement of the burner tap if found to be faulty.

REPLACING THE INJECTORS (see the injector table in the Instruction)

ADJUSTING MINIMUM GAS SETTING OF TAPS

REFERENCE TO LOCAL REGULATIONS

Ensure that the installation and gas connections are performed by a qualified technician, following the manufacturer's 
instructions and in compliance with current local safety regulations.

AFTER-SALES SERVICE

 WARNING

This operation must be performed by a qualified technician.

 WARNING

The electrical connections must comply 
with local regulations.

The earthing of this appliance is 
compulsory by law.

Do not use an extension cord.

After having cleaned the perimeter surface, 
apply the supplied gasket to the hob as shown 
in the figure.

Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction.

NOTE: the power supply cable must be long enough to permit its upward extraction.

To secure the hob, use the brackets (

A

) provided with it. Fit the brackets into the relevant bores shown by the arrow and 

fasten them by means of their screws in accordance with the thickness of the worktop (see the following figures). 

 WARNING

This operation must be performed by a qualified technician.

L

N

Earth

(yellow/green)

20

30

60

40

Top 20 mm

Top 40 mm

Top 30 mm

Top 60 mm

Remove grids (

A

).

Extract  burners  (

B

).

Using a socket spanner of the appropriate size unscrew 
the injector (

C

), unscrew the injector to be replaced.

Replace it with the injector suitable for the new type of 
gas.

Re-assemble the injector in (

D

).

If you have a multiple crown burner use side spanner to 
replace the injector (

E

).

Before installing the hob, remember to affix the gas 
calibration plate supplied with the injectors in such a way 
that it covers the existing information relating to gas 
calibration.

To ensure that the minimum setting is correctly adjusted, remove the knob and proceed 
as follows:

tighten screw to reduce the flame height (-);

loosen screw to increase the flame height (+).

The adjustment must be performed with the tap in minimum gas setting position (small 

flame) .

The primary air of the burners does not need to be adjusted.

At this stage, light up the burners and turn the knobs from max position   to 

minimum position   to check flame stability.

Upon completion of adjustment, reseal using sealing wax or an equivalent material.

Before calling the After-Sales Service, make sure you can give the following information:
-

type of fault or problem;

-

exact model (written on the label affixed to the instruction/warranty);

-

service number that follows the word SERVICE on the rating plate under the hob and 
on the label affixed to instruction/warranty;

-

your complete address and phone number.

If any repairs are required, please contact an authorised After-Sales Service, as indicated in the 
warranty.

Summary of Contents for AKT 464

Page 1: ...CAL INFORMATION FOR THE INSTALLER This product can be embedded in a worktop 20 to 60 mm thick If there is no oven beneath the hob insert a separator panel that has a surface at least equal to the opening in the work surface This panel must be positioned at a maximum distance of 150 mm below the upper surface of the work surface but in no case less than 20 mm from the bottom of the hob In the case ...

Page 2: ... the Instruction NOTE the power supply cable must be long enough to permit its upward extraction To secure the hob use the brackets A provided with it Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws in accordance with the thickness of the worktop see the following figures WARNING This operation must be performed by a qualified technician L N Ear...

Page 3: ... that none of the burner openings is clogged Rinse and dry Refit burners and burner caps correctly in the respective housings When replacing the grids make sure that the panstand area is aligned with the burner Models equipped with electrical ignition plugs and safety device require thorough cleaning of the plug end in order to ensure correct operation Check these items frequently and if necessary...

Page 4: ...vered Make sure pots on the grates do not protrude beyond the edge of the hob IMPORTANT improper use of the grids can result in damage to the hob do not position the grids upside down or slide them across the hob Do not use Cast iron griddles ollar stones terracotta pots and pans Heat diffusers such as metal mesh or any other types Two burners simultaneously for one receptacle e g fish kettle Burn...

Reviews: