9
MAINTENANCE
GREASE FILTER
* The grease filters should be cleaned frequently (every two months of operation, or
more frequently for heavy use). Use a warm detergent solution.
* Grease filters are washable.
1. Remove the grease filter one by one by pulling
out each latch. This will disengage the filter from
the hood. Tilt the filter downward and remove.
2. Wash the filters, taking care not to bend them.
Allow them to be dry before refitting.
3. When refitting the filters, make sure that the handle is visible from the outside.
4. To install the grease filter, align rear filter tabs with slots in the hood. Pull out the
latch, push filter into position and release. Make sure the filter is securely
engaged after assembly.
HALOGEN BULBS
This range hood requires two halogen bulbs (Type JCD, 12V, 20W Max, G-4 Base)
WARNING:
Always switch off the electrical supply before carrying out any operation
on the appliance.
To change bulbs:
1. Kick off the halogen bulb cover
②
by using the flat screw driver.
2. Remove the bulb by pulling sideward (DO NOT ROTATE).
3. Replace with Type JCD, 12V, 20W Max, G-4 Base halogen bulb. Do not touch
replacement bulb with bare hands !