background image

033-03 - Electric kettles

11

mA

L1

L3

L2

N

C1

C2

R1

C1

C2

L1

L2

R1

R1

R1

1

TL

5

6

7

3

2

4

TS

LR

LA

5

4

P3 PL

1

3

P1

SE

8

10

9

SL

R1

R1

R1

R1

230 / 3V

L1

mA

L3

L2

L2

L1

mA

L3

PL

 

P1

 

P3

 

400V 3N

= BULBO TERMOSTATO

TS

TL

PV

M1

4SL

Only for mod. 200/300

Wiring diagrams

L1

Green operation light

L2

Orange operation light

LA

Red alarm operation light

LR

Orange reservoir light

TL

Working thermostat

TS

Safety thermostat

C1

Electromagnetic switch max

C2

Electromagnetic switch min

SL

Level card 

SE

Three position selector/switch

R1

Heating element

mA

Line terminal board

AGB 384/WP / AGB 386/WP
AGB 390/WP / AGB 392/WP

Summary of Contents for AGB 372/WP

Page 1: ...r installation use and maintenance 06 2009 ELECTRIC KETTLES 0033_GB_42 Validity from serial number 92204355 AGB 372 WP AGB 375 WP AGB 377 WP AGB 384 WP AGB 386 WP AGB 390 WP AGB 392 WP AGB 396 WP AGB 399 WP AGB 401 WP ...

Page 2: ...ial bonding 7 Connection to waterworks 7 Commissioning and testing pag 7 Maintenance of the appliance 7 Possible failures and their elimination 7 Use and cleaning 8 Warnings and hints for user 8 Instructions for use 8 Filling the jacket 8 Details regarding the operation of the pressure kettles 8 Switch on start of cooking and switch off 8 Cleaning and care of the appliance 8 Daily cleaning 9 Speci...

Page 3: ...C S 2 1 0 T C E F 1 2 3 4 5 6 Technical data plate Hot water connection to 10 mm Electrical connection Cold water connection to 10 mm Selector Operation light Pressure gauge Cooking vat drainage tap Vat water feed tap Jacket level tap Dimensions ...

Page 4: ...033 03 Electric kettles 4 Controls 0 4 0 6 0 80 1 0 0 0 4 0 6 0 8 0 10 0 0 2 3 1 0 2 3 1 0 2 3 1 0 2 3 1 Manual vapour vent Valve autoclave 0 Off 1 50 power 2 75 power 3 100 power ...

Page 5: ...r pressure kettle Width A Depth B Height C Vat diameter Vat height Total volume Usable volume Voltage Input Power Power cable Hot water connection Cold water connection Water pressure Jacket volume Jacket pressure mm mm mm mm mm lt lt kW mm mm kPa lt bar 800 900 875 600 415 110 100 3N 400V 50hz 16 5 x 2 5 mm2 10 10 50 300 0 5 800 900 875 600 540 145 135 3N 400V 50hz 18 5 x 6 mm2 10 10 50 300 0 5 1...

Page 6: ...adjusta ble feet A significantly uneven or sloping stance can affect the operation of the appliance adversely Installation Warning Only qualified technicians must perform the installation maintenance and test of the appliance Warning Before connecting any parts of the ap pliance to supplies make sure that the latter is equiva lent the requirements stated in the technical data plate if the applianc...

Page 7: ... all safety requirements in current standards statu tory regulations and directives have been met that the water connections are leak free that the electrical connection has been performed accor ding to standards In addition check that once the appliance has been instal led the power cord is neither subject to stretch nor in con tact with nor surfaces Now proceed to light the appliance as directed...

Page 8: ...that the valve is in a resting position Start cooking at full power When steam starts to come out of the valve reduce heating power The steam coming out of the valve must be constant and light The pressure inside the cooking vat can reach a maximum of 0 05 bar On request the appliance can be equipped with a pressure gauge that shows the pressure inside the cooking vat Turn off the appliance after ...

Page 9: ...nd the vat and or the jacket is are empty The manufacturer shall not be held responsible nor has any warranty commitments for damage caused by non compliance with prescriptions or by installa tion not in conformity with instructions The same applies in case of improper use or diffe rent application by the operator THE 2002 96 EC DIRECTIVE WEEE information to users This informational note is meant ...

Page 10: ... PE 1 2 3 4 5 6 1 2 3 4 5 6 0 P1 P2 P3 P4 SE 2 3 1 SE P1 P2 P3 P4 1 2 3 4 RM 1 3 5 2 4 6 1 3 5 2 4 6 12 11 2 1 AGB 372 WP AGB 375 WP AGB 377 WP AGB 396 WP AGB 399 WP AGB 401 WP mA Line input terminal board TS Safety thermostat C1 Electromagnetic switch L1 Pilot lamp green voltage L2 Pilot lamp yellow TL Thermostat R1 Heating element R2 Heating element SE Four position selector switch Rm Relay ...

Page 11: ...ATO T S T L PV M 1 4SL Only for mod 200 300 Wiring diagrams L1 Green operation light L2 Orange operation light LA Red alarm operation light LR Orange reservoir light TL Working thermostat TS Safety thermostat C1 Electromagnetic switch max C2 Electromagnetic switch min SL Level card SE Three position selector switch R1 Heating element mA Line terminal board AGB 384 WP AGB 386 WP AGB 390 WP AGB 392 ...

Page 12: ...O COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: