S E R V I C E
Whirlpool Europe
ADP 242 S WH
25.01.2001 / Page 3
Customer Service
8542 242 10510
Doc. No: 4812 718 16125
Technical data
Heating
1 Element system
Voltage
220/230
V
Power consumption
1.87/2.04 kW
Resistance
24.5
Ω
Heating speed
~ 2.0
˚C/min
Temperature on surface
~ 115
˚C
Safety thermostat
self reset
85
˚C
Potentiometer
Points of meassurement: 1(black) to 2 (middle)
Position 0
0.0
k
Ω
Position 1
0.5
k
Ω
Position 2
1.0
k
Ω
Position 3
1.4
k
Ω
Position 4
1.8
k
Ω
Position 5
2.3
k
Ω
Position 6
2.6
k
Ω
Water valves
Single valve at inlet hose
Voltage
220/240
V
Frequency
50/60
Hz
Resistance
3.76
k
Ω
Regenerating valve
Voltage
220/240
V
Frequency
50/60
Hz
Resistance
3.13
k
Ω
Coil of dispenser
Voltage
220/240
V
Frequency
50/60
Hz
Resistance
1.5
k
Ω
Reedcontact
flow meter
Accesory
If you need spare parts apart from the spare part
list have a look in the
Service Bulletin 4812 718 40084.
NTC
20 ˚C
58.1
k
Ω
25 ˚C
47.1
k
Ω
30 ˚C
38.2
k
Ω
40 ˚C
25.4
k
Ω
50 ˚C
17.2
k
Ω
60 ˚C
11.8
k
Ω
70 ˚C
8.3
k
Ω
80 ˚C
6
k
Ω
85 ˚C
4
k
Ω
Regeneration
Volume
300
cm
3
Position 0
after wash cycles
-
water hardness
0-5
˚dh
0-0.9
mmol/l
0-9
˚Fh
Position 1
after wash cycles
8
water hardness
6-10
˚dh
1-1.8
mmol/l
10-18
˚Fh
Position 2
after wash cycles
6
water hardness
11-15
˚dh
1.9-2.7
mmol/l
19-27
˚Fh
Position 3
after wash cycles
4
water hardness
16-21
˚dh
2.8-3.7
mmol/l
28.37
˚Fh
Position 4
after wash cycles
3
water hardness
22-28
˚dh
3.8-5.0
mmol/l
38-50
˚Fh
Position 5
after wash cycles
2
water hardness
29-35
˚dh
5.1-6.3
mmol/l
51-63
˚Fh
Position 6
after wash cycles
1
water hardness
36-60
˚dh
6.4-10.7
mmol/l
64-107
˚Fh
Salt consumption
for regeneration
77
g
Number of cycles
with 2 kg salt
26