You can solve many common air conditioner problems easily, saving you the cost of a service call. Try the suggestions below to 
see whether you can solve your problem without outside help.

Air conditioner will not operate

The power supply cord is unplugged. Plug into a grounded 
3 prong outlet. See “Electrical Requirements.”

The power supply cord has tripped (Reset button has 
popped out; on some devices, a green light will turn off). 
Press and release RESET (listen for click; Reset button will 
latch and remain in; on some devices, a green will turn on) to 
resume operation.

A household fuse has blown, or a circuit breaker has 
tripped. 
Replace the fuse, or reset the circuit breaker. See 
“Electrical Requirements.”

Depending on model, the Power button has not been 
pressed or the Fan Speed control is turned to Off. 
Press 
POWER button or turn the FAN SPEED control to an active 
setting.

The local power has failed. Wait for power to be restored.

Air conditioner blows fuses or trips circuit breakers

Too many appliances are being used on the same circuit. 
Unplug or relocate appliances that share the same circuit.

Time-delay fuse or circuit breaker of the wrong capacity 
is being used. 
Replace with a time-delay fuse or circuit 
breaker of the correct capacity. See “Electrical 
Requirements.”

An extension cord is being used. Do not use an extension 
cord with this or any other appliance.

You are trying to restart the air conditioner too soon after 
turning the unit off. 
Wait at least 3 minutes after turning the 
unit off before trying to restart the air conditioner.

Air conditioner power supply cord trips (Reset button 
will pop out)

Disturbances in your electrical current can trip (Reset 
button will pop out; on some devices, a green light will 
turn off) the power supply cord.
 Press and release RESET 
(listen for click; Reset button will latch and remain in; on some 
devices, a green light will turn on) to resume operation.

An electrical overloading, overheating, pinching or aging 
can trip (Reset button will pop out; on some devices, a 
green light will turn off) the power supply cord.
 After 
correcting the problem, press and release RESET (listen for 
click; Reset button will latch and remain in; on some devices, 
a green light will turn on) to resume operation.

NOTE: A damaged power supply cord must be replaced with a 
new power supply cord obtained from the product manufacturer 
and must not be repaired.

Air conditioner seems to run too much

The current air conditioner replaced an older model. The 
use of more efficient components may cause the air 
conditioner to run longer than an older model, but the total 
energy consumption will be less. Newer air conditioners do 
not emit the “blast” of cold air you may be accustomed to 
from older units, but this is not an indication of lesser cooling 
capacity or efficiency. Refer to the efficiency rating (EER) and 
capacity rating (in BTUs/hr.) marked on the air conditioner.

The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room. 
Use exhaust 
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A 
higher capacity air conditioner may be required, depending 
on the size of the room being cooled.

Air conditioner cycles on and off too much or does not 
cool

The Mode is set to Power Saver (on some models). Use 
Power Saver only when you are asleep or away from home, 
since the fan does not circulate the room air continuously. 
Use Low, High or Turbo for your best comfort.

The air conditioner is not properly sized for your room. 
Check the cooling capabilities of your room air conditioner. 
Room air conditioners are not designed to cool multiple 
rooms. 

The filter is dirty or obstructed by debris. Clean the filter. 

The inside evaporator and outside condenser coils are 
dirty or obstructed by debris.
 See “Annual Maintenance.”

There is excessive heat or moisture (open container 
cooking, showers, etc.) in the room.
 Use a fan to exhaust 
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.

The louvers are blocked. Install the air conditioner in a 
location where the louvers are free from curtains, blinds, 
furniture, etc.

The outside temperature is below 65°F (18°C). Do not try to 
operate your air conditioner in the cooling mode when the 
outside temperature is below 65°F (18°C).

The temperature of the room you are trying to cool is 
extremely hot. 
Allow extra time for the air conditioner to cool 
off a very hot room.

Windows or doors to the outside are open. Close all 
windows and doors.

The Exhaust control is set to OPEN (on some models). 
Push the Exhaust control CLOSED for maximum cooling.

Depending on model, the Temp/Time or Temperature 
control is not at a cool enough setting. 
Adjust the TEMP/
TIME control to a cooler setting by pressing the minus button 
to reduce the temperature, or adjust the TEMPERATURE 
control to a cooler setting by turning the knob clockwise. Set 
the FAN SPEED control to Turbo or Turbo Cool.

Water drips from cabinet into your house

The air conditioner is not properly leveled. The air 
conditioner should slope slightly downward toward the 
outside. Level the air conditioner to provide a downward 
slope toward the outside to ensure proper drainage. See the 
Installation Instructions. 

NOTE: Do not drill a hole in the bottom of the metal base and 
condensate pan.

Summary of Contents for ACQ088MS

Page 1: ...3 1301 or visit our website at www whirlpool com ACONDICIONADOR DE AIRE PARA HABITACIÓN ManualdeUsoyCuidado Si tiene preguntas respecto a las características funcionamiento rendimiento partes accesorios o servicio técnico llame al 1 800 253 1301 o visite nuestro sito web en www whirlpool com Table of Contents Índice 2 326042338 ...

Page 2: ...ÓMO USAR SU ACONDICIONADOR DE AIRE 21 Cómo poner en marcha su acondicionador de aire Control digital 21 Cómo cambiar la dirección del aire 24 Sonidos normales 24 CÓMO CUIDAR SU ACONDICIONADOR DE AIRE 25 Limpieza del filtro de aire 25 Limpieza del panel delantero 25 Reparación de la pintura dañada 25 Mantenimiento anual 25 SOLUCIÓN DE PROBLEMAS 26 AYUDA O SERVICIO TÉCNICO 27 En los EE UU 27 Accesor...

Page 3: ...ght of air conditioner Air conditioner weighs 56 lbs 25 kg to 80 lbs 36 kg NOTE Cabinet louvers must not be obstructed Air must be able to pass freely through the cabinet louvers Window installation Window opening measurements 26 66 cm minimum to 38 95 5 cm maximum opening width 16 40 6 cm minimum opening height IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or i...

Page 4: ...ense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button will trip and pop out 4 Press and release RESET listen for click Reset button will latch and remain in The power sup...

Page 5: ... with care 1 Locate provided bags of screws 2 Place the top channel on top of the air conditioner lining up the holes in top channel with the holes on top of air conditioner 3 Using 3 10 x pan head screws attach top channel to air conditioner Install side curtains NOTE Attach curtains to unit before placing unit in window 1 Insert curtain into curtain frame 2 Push curtain in all the way 3 Pull cur...

Page 6: ...indow Check that feet on bottom of air conditioner are behind and against back side of windowsill Lower window sash to hold cabinet in place 2 Pull left hand curtain frame out until it fits into the window channel Repeat with right hand curtain frame Attach side curtains to window 1 Insert one of the 8 x round head screws through left hand curtain frame and into the window channel to fasten the cu...

Page 7: ...ir conditioner in the cooling mode when outside temperature is below 65 F 18 C The inside evaporator coil will freeze up and the air conditioner will not operate properly NOTE In the event of a power failure your air conditioner will operate at the previous settings when the power is restored StartingYourAirConditioner Digital Control NOTES When the air conditioner is off the Room indicator light ...

Page 8: ...selected 1 Press FAN SPEED until you see the indicator light come on for the setting you desire 2 Choose Turbo High or Low Filter Reset 1 When Filter indicator light is lit remove clean and replace air filter See Cleaning the Air Filter 2 Press and hold FILTER for 3 seconds after replacing the air filter NOTE After 360 hours of fan operating time the Filter indicator light will turn on It will rem...

Page 9: ...flash Hour indicator light will turn on and display will show remaining hours before air conditioner will turn on 7 Press the plus or minus button to change delay time 1 to 24 hours 8 Press TIMER again or wait 10 seconds Timer indicator light will remain on Hour indicator light will turn off and Room indicator light will turn on Display will show current room temperature To clear Timer delay progr...

Page 10: ...r light on air conditioner will remain on Hour indicator light on air conditioner will turn off and Room indicator light on air conditioner will turn on Display on air conditioner will show the current room temperature To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Timer indicator light on air conditioner will flash Hour indicator light o...

Page 11: ...the filter in place 1 Turn off air conditioner 2 Remove air filter by sliding filter out from either side of unit 3 Use a vacuum cleaner to clean air filter If air filter is very dirty wash it in warm water with a mild detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency 4 Replace air filter by slidi...

Page 12: ...lder model but the total energy consumption will be less Newer air conditioners do not emit the blast of cold air you may be accustomed to from older units but this is not an indication of lesser cooling capacity or efficiency Refer to the efficiency rating EER and capacity rating in BTUs hr marked on the air conditioner The air conditioner is in a heavily occupied room or heat producing appliance...

Page 13: ...e number in your correspondence Please record your model s information Whenever you call to request service on your appliance you need to know your complete model number and serial number You can find this information on the model and serial number label See Electrical Requirements for model and serial number location Please record the model and serial number information below Also record the purc...

Page 14: ...14 Notes ...

Page 15: ...r la muerte o una y de la palabra PELIGRO o ADVERTENCIA Estas palabras significan PELIGRO ADVERTENCIA a usted y a los demás Lea y obedezca siempre todos los mensajes de seguridad Todos los mensajes de seguridad irán a continuación del símbolo de advertencia de seguridad puede morir lesión INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA Para reducir el riesgo de incendio choque eléctrico o lesio...

Page 16: ...lo y serie está ubicada en el lado derecho del gabinete Los requisitos eléctricos específicos se indican en la siguiente tabla Siga los requisitos para el tipo de enchufe en el cable de suministro de energía Método recomendado para la puesta a tierra Para su seguridad personal este acondicionador de aire debe ser puesto a tierra Este acondicionador de aire está equipado con un cable de suministro ...

Page 17: ...posición se atrapa y salta 4 Presione y suelte RESET escuche el chasquido el botón de reposición queda asegurado y se mantiene asegurado El cable de suministro de energía está listo para su funcionamiento NOTAS El botón de reposición debe presionarse para el funcionamiento adecuado El cable de suministro de energía debe ser reemplazado si no se dispara cuando se presione el botón de prueba o cuand...

Page 18: ...rte superior del acondicionador de aire alineando los orificios en el canal superior con los orificios en la parte superior del acondicionador de aire 3 Utilice 3 tornillos de cabeza plana 10 x para fijar el canal superior al acondicionador de aire Instalación de las cortinas laterales NOTA Sujete las cortinas a la unidad antes de colocar la unidad en la ventana 1 Inserte la cortina en el marco de...

Page 19: ... la ventana Verifique que las patas de la parte inferior del acondicionador de aire estén detrás y contra la parte trasera del obturador de la ventana Baje el marco de la ventana para mantener el acondicionador de aire en su lugar 2 Jale del marco de la cortina izquierda hacia afuera hasta que encaje en la ranura de la ventana Repita el procedimiento para el marco de la cortina derecha Fije las co...

Page 20: ...zar a través del orificio en el soporte en el marco de la ventana 6 Fije el soporte de seguridad de la ventana al marco de la ventana con un tornillo de cabeza redonda 8 x para asegurar la ventana en su lugar 7 Conecte a un contacto de pared de conexión a tierra de 3 terminales 8 Presione RESET Reposición sobre el cable de suministro de energía A Tornillos de cabeza redonda 8 x A Marco de la venta...

Page 21: ...rlo enchufado mostrará en la pantalla los ajustes programados Modo Cool Enfriamiento velocidad de ventilación Turbo 72 F 22 C por 3 segundos Cuando se encienda todas las otras veces mostrará la temperatura de la habitación 3 Selecccione el modo Vea Mode Modo 4 Selecccione la velocidad de ventilación Vea Fan Speed Velocidad de ventilación 5 Selecccione la temperatura Vea Temperatura Mode Modo 1 Opr...

Page 22: ...enga los botones de MODE Modo y FAN SPEED Velocidad de ventilación a la vez que presiona para encender el acondicionador de aire NOTA Siga estos mismos pasos para cambiar la pantalla de la temperatura de C a F Retardo del temporizador Para programar el temporizador para un retardo de 1 a 24 horas hasta que el acondicionador de aire se apague el acondicionador de aire tiene que estar Encendido 1 Op...

Page 23: ...ía Para seleccionar el modo Oprima AUTO COOL Enfriamiento automático COOL Enfriamiento FAN ONLY Sólo ventilación o POWER SAVER Ahorro de energía Auto Cool Enfriamiento automático la velocidad de ventilación se ajusta automáticamente Cool Enfriamiento Fan Only Sólo ventilación o POWER SAVER Ahorro de energía la velocidad de ventilación se ajusta automáticamente Para seleccionar la velocidad de vent...

Page 24: ...de aire se encienda cambiando los ajustes previos 1 Encienda el acondicionador de aire 2 Ajuste el Modo a Auto Cool Cool Fan Only o Power Saver NOTA Para el modo Auto automático vaya al paso 4 3 Para el modo Cool fresco Fan Only Sólo ventilador o Power Saver ahorro de energía ajuste Fan Speed velocidad del ventilador a Turbo High alta o Low baja 4 Ajuste la temperatura entre 64 F 18 C y 86 F 30 C ...

Page 25: ...vamente para asegurarse la máxima eficiencia 4 Vuelva a colocar el filtro de aire deslizándolo nuevamente en cualquiera de los lados de la unidad Limpiezadelpaneldelantero 1 Desenchufe el acondicionador de aire o desconecte el suministro de energía 2 Quite el filtro de aire y límpielo por separado Vea Limpieza del filtro de aire 3 Limpie el panel delantero con un paño suave y húmedo 4 Seque el pan...

Page 26: ... Un cable de suministro de energía dañado debe ser reemplazado por un nuevo cable de suministro de energía obtenido del fabricante del producto y no debe ser reparado Parece que el acondicionador de aire funciona excesivamente Su actual acondicionador de aire reemplazó un modelo viejo El uso de componentes más eficientes puede hacer que el acondicionador de aire funcione por más tiempo que su anti...

Page 27: ...para reparación Los técnicos de servicio designados están entrenados para cumplir con la garantía del producto y ofrecer servicio una vez que la garantía termine en cualquier lugar de los Estados Unidos Para localizar la compañía de servicio autorizada en su área también puede consultar la sección amarilla de su guía telefónica Para obtener más asistencia Si necesita asistencia adicional puede esc...

Page 28: ...os derechos reservados Registered Trademark TM Trademark of Whirlpool U S A Whirlpool Canada Inc Licensee in Canada Marca registrada TM Marca de comercio de Whirlpool EE UU Uso Bajo licencia de Whirlpool Canada Inc en Canadá 8 04 Printed in Brazil Impreso en Brasil ...

Reviews: