background image

5

Gas Supply Requirements

Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 

Type of Gas 

Natural gas:

This range is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 

This range is factory set for use with Natural gas. See “Gas 
Conversions” section. The model/serial rating plate located on 
the frame behind the storage drawer has information on the 
types of gas that can be used. If the types of gas listed do not 
include the type of gas available, check with the local gas 
supplier.

LP gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See “Gas 
Conversions” section.

Gas Supply Line 

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range 
location. A smaller size pipe on longer runs may result in 
insufficient gas supply. Pipe-joint compounds that resist the 
action of LP gas must be used. Do not use TEFLON

®†

 tape. 

With LP gas, piping or tubing size can be ½" (1.3 cm) 
minimum. Usually, LP gas suppliers determine the size and 
materials used in the system.

Flexible metal appliance connector:

If local codes permit, a new CSA design-certified, 
4 - 5 ft (122 - 152.4 cm) long, ½" (1.3 cm) or 
¾" (1.9 cm) I.D., flexible metal appliance connector may 
be used for connecting range to the gas supply line. 

A ½" (1.3 cm) male pipe thread is needed for connection 
to the female pipe threads of the inlet to the appliance 
pressure regulator. 

Do not kink or damage the flexible metal tubing when 
moving the range.

Rigid pipe connection: 

The rigid pipe connection requires a combination of pipe 
fittings to obtain an in-line connection to the range. The rigid 
pipe must be level with the range connection. All strains must 
be removed from the supply and fuel lines so range will be 
level and in line.

Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff valve. 
This valve should be located in the same room but external to 
the range. It should be in a location that allows ease of 
opening and closing. Do not block access to shutoff valve. 
The valve is for turning on or shutting off gas to the range.

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be used. 
The inlet pressure to the regulator should be as follows for proper 
operation:
Natural gas:

Minimum pressure: 5" WCP
Maximum pressure: 14" WCP

LP gas:

Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet 
pressure.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

A. Gas supply line
B. Shutoff valve “open” position

C. To range

†®T

EFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A

B

C

Summary of Contents for 9762998

Page 1: ...e installation instructions for local electrical inspector s use 9762998 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of o...

Page 2: ... phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier In the State of Massachusetts the following installation instructions apply Installations and repairs must be pe...

Page 3: ...t must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at least 200 F 93 C Use an insulated p...

Page 4: ...qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommen...

Page 5: ...e connector may be used for connecting range to the gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the range Th...

Page 6: ...n Ranges Equipped with Warming Drawers Use channel lock pliers to lower the front and rear leveling legs one half turn Install Anti Tip Bracket Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering Before moving range slide range onto shipping base cardboard or hardboard 1 Remove template from the anti tip bracket kit fo...

Page 7: ...hite wheels in drawer guides Remove drawer and set it aside on a protected surface See the Use and Care Guide for the model drawer removal 2 Making sure the anti tip bracket is installed Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket 3 If installing the range in a mobile home you must secure the range to the floor Any method o...

Page 8: ... not light Place burner grates over burners and caps 5 Plug into a grounded 3 prong outlet Electronic Ignition System Initial lighting and gas flame adjustments Cooktop and oven burners use electronic igniters in place of standing pilots When the cooktop control knob is turned to the LITE position the system creates a spark to light the burner This sparking continues as long as the control knob is...

Page 9: ... to HI checking the flame at each setting Check Operation of Oven Bake Burner 1 Remove the oven rack 2 To remove the oven bottom Remove 2 screws at the rear of the oven bottom Lift the rear of the oven bottom up and back until the front of the panel is away from the front frame Remove from oven and place the cover on a protected surface 3 You can check the burner flame by removing the flame spread...

Page 10: ...push firmly to close drawer Complete Installation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See Level Range 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused...

Page 11: ...ver over gas pressure regulator cap A To range B Manual shutoff valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heat...

Page 12: ...h burner location 5 Place Natural gas orifice spuds in the cardboard orifice spud holder 6 Replace the burner base using both screw 7 Replace burner cap 8 Repeat steps 1 7 for the remaining burners To Convert Oven Bake Burner 1 Remove oven racks 2 Use a combination wrench to turn the orifice hood down snug onto pin about 2 to 2 turns IMPORTANT Do not overtighten The oven bake burner flame cannot b...

Page 13: ... drawer Locate gas pressure regulator at rear of storage or warming drawer compartment NOTE On models with a warming drawer an access cover must be removed from the gas pressure regulator IMPORTANT Do not remove the gas pressure regulator Gas pressure regulator 3 Remove plastic cover from gas pressure regulator cap 4 Turn gas pressure regulator cap counterclockwise with a combination wrench to rem...

Page 14: ...ersion is not made See Adjust Oven Bake Burner Flame section To Convert Oven Broil Burner Use a combination wrench to loosen the orifice hood away from the pin about 2 to 2 turns The oven broil burner flame cannot be properly adjusted if this conversion is not made See Adjust Oven Broil Burner Flame section Replace Oven Racks and Storage or Warming Drawer Replace oven racks in oven cavity Insert s...

Page 15: ...15 Notes ...

Page 16: ...IP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge 9762998 2005 All rights reserved 12 05 Printed in U S A ...

Reviews: