Installation Clearances

Cabinet opening dimensions shown are for 25" (64 cm) 
countertop depth, 24" (61 cm) base cabinet depth and
36" (91.4 cm) countertop height.
If the cabinet depth is greater than 24" (61 cm), oven frame must 
extend beyond cabinet fronts by ½" (13 mm) minimum.

*NOTE: 24" (61 cm) minimum when bottom of wood or metal 

cabinet is protected by not less than 

¹⁄₄

" (0.64 cm) flame retardant 

millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.

 30" (76.2 cm) minimum clearance between the top of the cooking 

platform and the bottom of an unprotected wood or metal 
cabinet.

If installing a hood above the range, follow the instructions for 
dimensional clearances above the cooktop surface.
IMPORTANT: Some cabinet and building materials are not 
designed to withstand the heat produced by the oven for baking 
and self-cleaning. Check with your builder or cabinet supplier to 
make sure that the materials used will not discolor, delaminate or 
sustain other damage.

Electrical Requirements

IMPORTANT: The range must be electrically grounded in 
accordance with local codes and ordinances, or in the absence of 
local codes, with the National Electrical Code, ANSI/NFPA 70 or 
Canadian Electrical Code, CSA C22.1.
This range is equipped with an electronic ignition system that will 
not operate if plugged into an outlet that is not properly polarized.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:

 National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this range be provided.

Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 

The wiring diagram is located on the back of the range in a 
clear plastic bag.

NOTE: The metal chassis of the range must be grounded in 
order for the control panel to work. If the metal chassis of the 
range is not grounded, no keypads will operate. Check with a 
qualified electrician if you are in doubt as to whether the metal 
chassis of the range is grounded.

A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth

C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE*.

E. 30

¹⁄₈

" (76.5 cm) min. opening width

F. This shaded area recommended for installation of rigid gas pipe.

G. 8" (20.3 cm)
H. Grounded outlet

I. 17" (43.2 cm)

J. 2" (5.1 cm)

K. 4

¹⁄₂

" (11.4 cm)

L. 2" (5.0 cm) min. clearance from both sides of range to side wall 

or other combustible material.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

Summary of Contents for 9762998

Page 1: ...e installation instructions for local electrical inspector s use 9762998 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of o...

Page 2: ... phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier In the State of Massachusetts the following installation instructions apply Installations and repairs must be pe...

Page 3: ...t must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at least 200 F 93 C Use an insulated p...

Page 4: ...qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommen...

Page 5: ...e connector may be used for connecting range to the gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the range Th...

Page 6: ...n Ranges Equipped with Warming Drawers Use channel lock pliers to lower the front and rear leveling legs one half turn Install Anti Tip Bracket Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering Before moving range slide range onto shipping base cardboard or hardboard 1 Remove template from the anti tip bracket kit fo...

Page 7: ...hite wheels in drawer guides Remove drawer and set it aside on a protected surface See the Use and Care Guide for the model drawer removal 2 Making sure the anti tip bracket is installed Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket 3 If installing the range in a mobile home you must secure the range to the floor Any method o...

Page 8: ... not light Place burner grates over burners and caps 5 Plug into a grounded 3 prong outlet Electronic Ignition System Initial lighting and gas flame adjustments Cooktop and oven burners use electronic igniters in place of standing pilots When the cooktop control knob is turned to the LITE position the system creates a spark to light the burner This sparking continues as long as the control knob is...

Page 9: ... to HI checking the flame at each setting Check Operation of Oven Bake Burner 1 Remove the oven rack 2 To remove the oven bottom Remove 2 screws at the rear of the oven bottom Lift the rear of the oven bottom up and back until the front of the panel is away from the front frame Remove from oven and place the cover on a protected surface 3 You can check the burner flame by removing the flame spread...

Page 10: ...push firmly to close drawer Complete Installation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See Level Range 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused...

Page 11: ...ver over gas pressure regulator cap A To range B Manual shutoff valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heat...

Page 12: ...h burner location 5 Place Natural gas orifice spuds in the cardboard orifice spud holder 6 Replace the burner base using both screw 7 Replace burner cap 8 Repeat steps 1 7 for the remaining burners To Convert Oven Bake Burner 1 Remove oven racks 2 Use a combination wrench to turn the orifice hood down snug onto pin about 2 to 2 turns IMPORTANT Do not overtighten The oven bake burner flame cannot b...

Page 13: ... drawer Locate gas pressure regulator at rear of storage or warming drawer compartment NOTE On models with a warming drawer an access cover must be removed from the gas pressure regulator IMPORTANT Do not remove the gas pressure regulator Gas pressure regulator 3 Remove plastic cover from gas pressure regulator cap 4 Turn gas pressure regulator cap counterclockwise with a combination wrench to rem...

Page 14: ...ersion is not made See Adjust Oven Bake Burner Flame section To Convert Oven Broil Burner Use a combination wrench to loosen the orifice hood away from the pin about 2 to 2 turns The oven broil burner flame cannot be properly adjusted if this conversion is not made See Adjust Oven Broil Burner Flame section Replace Oven Racks and Storage or Warming Drawer Replace oven racks in oven cavity Insert s...

Page 15: ...15 Notes ...

Page 16: ...IP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge 9762998 2005 All rights reserved 12 05 Printed in U S A ...

Reviews: