Gas supply requirements

WARNING

Explosion Hazard

Use a new AGA or CSA approved gas
supply line.

Install a shutoff valve.

Securely tighten all gas connections.

If connected to LP, have a qualified
person make sure gas pressure does
not exceed 14" (35.6 cm) water column.

Examples of a qualified person
include:

licensed heating personnel,
authorized gas company
personnel, and

Failure to do so can result in death,
explosion, or fire.

authorized service personnel.

In the State of Massachusetts, the
following installation instructions
apply:

• Installations and repairs must be

performed by a qualified or licensed
contractor, plumber, or gasfitter
qualified or licensed by the State 
of Massachusetts.

• If using a ball valve, it shall be a 

T-handle type.

• A flexible gas connector, when used,

must not exceed 3 feet.

Observe all governing codes and
ordinances.

This installation must conform with local
codes and ordinances. In the absence of
local codes, installations must conform
with American National Standard,
National Fuel Gas Code ANSI Z223.1 —
latest edition*.

Input ratings shown on the model/serial
rating plate are for elevations up to 2,000
feet (610 m). For assistance when
installing the range at higher elevations,
contact your local service company.

Type of gas:  This range is design-
certified by CSA International for use
with Natural gas or, after proper
conversion, for use with L.P. gas.  This
range is factory set for use with Natural
gas.  Gas conversion instructions are
provided in “Gas conversions” section.
The model/serial rating plate located on
the frame behind the storage drawer or
broiler door has information on the type
of gas that can be used.  If the type of
gas listed does not agree with the type of
gas available, check with the local gas
supplier.  Conversion must be done by a
qualified service technician.

Gas supply line: Provide a gas supply
line of 3/4" rigid pipe to the range
location. With L.P. gas, piping or tubing
size can be 1/2" minimum. A smaller size
pipe on longer runs may result in
insufficient gas supply. Usually, L.P. gas
suppliers determine the size and
materials used in the system.

Pipe-joint compounds made for use with
L.P. gas must be used on pipe threads
only.

Flexible metal appliance connector: If
local codes permit, a new AGA or CSA
design-certified, 1/2" or 3/4" I.D., flexible
metal appliance connector is
recommended for  connecting range to
the gas supply line. A 1/2" male pipe
thread nipple is needed for connection to
pressure regulator female pipe threads.
Do not kink or damage the flexible metal
tubing when moving the range. 

Rigid pipe
connection:
Requires a
combination of
pipe fittings to
obtain an in-line connection to the range.
All strains must be removed from the
supply and fuel lines so range will be
level and in line.

Shutoff valve: The supply line must be
equipped with a manual shutoff valve.
This valve should be located in the same
room as the range and should be in a
location that allows ease of opening and
closing. The valve is for turning on or
shutting off gas to the range. Do not
block access to shutoff valve.

Pressure regulator: The gas pressure
regulator supplied with this range must
be used. The inlet pressure to the
regulator should be as follows for proper
operation:

NATURAL GAS:

Minimum pressure: 5 inches W.C.
Maximum pressure: 14 inches W.C. 

L.P. GAS:

Minimum pressure: 11 inches W.C.
Maximum pressure: 14 inches W.C. 

Contact local gas supplier if you are not
sure about the inlet pressure.

Line pressure testing above 1/2 psi gauge 
(14" WCP) — The range and its individual
manual shutoff valve must be
disconnected from the gas supply piping 
system during any pressure testing of
that system at test pressures greater than
1/2 psig (3.5 kPa).

Line pressure testing at 1/2 psi gauge 
(14" WCP) or lower — The range must be
isolated from the gas supply piping
system by closing its individual manual
shutoff valve during any pressure testing
of that system at test pressures equal to
or less than 1/2 psig (3.5 kPa).

Copies of the standards listed may be obtained
from:

* CSA International

8501 East Pleasant Valley Rd.
Cleveland, Ohio  44131-5575

manual shutoff valve
“open” position

to range

gas supply

Summary of Contents for 9758660

Page 1: ...T Read and save these instructions 9758660 Part No 9758660 30 Freestanding Sealed Burner Gas Range with self cleaning oven WARNING Tip Over Hazard A child or adult can tip the range and be killed Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults www whirlp...

Page 2: ...nstallation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition installation codes It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Proper installation is your...

Page 3: ...a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate and that the outlet is correctly polarized Do not ground to a gas pipe Check with a qualified electrician if you are not sure range is properly grounded A 120 volt 60 Hz AC only 10 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It ...

Page 4: ...pe on longer runs may result in insufficient gas supply Usually L P gas suppliers determine the size and materials used in the system Pipe joint compounds made for use with L P gas must be used on pipe threads only Flexible metal appliance connector If local codes permit a new AGA or CSA design certified 1 2 or 3 4 I D flexible metal appliance connector is recommended for connecting range to the g...

Page 5: ...rea recommended for installation of rigid gas pipe Flexible gas pipe and electrical outlet are recommended in either shaded area 13 33 cm max upper cabinet depth If cabinet depth is greater than 24 61 cm oven frame must extend beyond cabinet fronts by 1 2 13 mm min 30 1 8 76 5 cm opening width 30 76 2 cm min cabinet opening width 4 1 2 11 4 cm 4 1 2 11 4 cm 2 5 1 cm IMPORTANT Some cabinet and buil...

Page 6: ...t is installed Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket Replace storage drawer anti tip bracket range foot 7 If installing the range in a mobile home you must secure the range to the floor Any method of securing the range is adequate as long as it conforms to the Manufactured Home Construction and Safety Standards 8 Plac...

Page 7: ...ll connections by brushing on an approved non corrosive leak detection solution Bubbles will show a leak If a leak appears shut off gas supply valve and tighten connections Then check connections again Clean all leak detection solution from gas connections Close broiler door 13 Center the burner cap on burner base Burner cap should be level when properly positioned Place burner grates over burner ...

Page 8: ...o 350 F Check operation Electronic ignition system Cooktop and oven burners use electronic ignitors in place of standing pilots When a cooktop control knob is turned to the LIGHT position the system creates a spark to light the burner This sparking continues until the control knob is turned to the desired setting When the oven control is set to the desired setting a series of sparks lights the ove...

Page 9: ...hould light within 8 seconds If your range has an oven temperature control knob Push in and turn the oven selector control knob to BROIL If the burner fails to light due to air remaining in the gas line reset the oven control by turning selector knob to OFF and then again to BROIL CLEAN 200 300 400 450 BROIL PUSH TO TURN OFF PUSH TO TURN WARM 250 350 500 OVEN ON TURN OFF OVEN WHEN FLASHING OVEN HE...

Page 10: ...emaining orifice spuds one at a time Place the Natural gas spuds on the spud card on the back of the range for future use Replace burner caps using both screws and burner grates Gas conversions Gas conversions from Natural gas to L P gas or from L P gas to Natural gas must be done by a qualified installer Fire Hazard Shut off gas supply line valve Make all conversions before turning gas supply val...

Page 11: ...ss orifice spuds in the center of each burner throat about 2 5 cm below the cooktop Apply masking tape to the end of a 5 16 nut driver to fit snugly over the orifice spud Press driver down onto the spud of the left front burner and remove by turning spud counter clockwise and lifting it out Replace the L P gas spud with the appropriate Natural gas spud shown in the table Continue to replace the re...

Page 12: ...rlpool Corporation Benton Harbor Michigan 49022 2 2004 7 Check that range is level 8 Reconnect gas line to range and check for leaks 9 Plug in range or reconnect power 10 Reinstall storage drawer Moving the range anti tip bracket range foot If you need assistance If you have questions about operating cleaning or maintaining your range Refer to Use and Care Guide Call the Customer Interaction Cente...

Reviews: