background image

S E R V I C E

31.03.1998 / Page 2

945 330 85

Whirlpool Europe

Doc. No: 4812 715 17852

8541 744 12000

Customer Service

Technical data

Type of gas used

Type of

burner

Injector

marking

Rated heat

capacity

PCS-kW

Rated

consumption

Reduced heat

capacity

PCS-kW

Gas pressure (mbar)

min.

rat.

max.

Natural Gas
(Methane)
G 25

large

medium

small

129

99
78

3,00
1,65
1,00

332 l/h
183 l/h

111 l/h

0,60
0,35
0,35

20

25

30

Type of gas used

Appliance

model

Total rated heat

capacity

PCS-kW

Total rated

consumption

Air required for

burning m/h

G20 25 mbar

4 gas

7,30

809 l/h

14,6

1. Medium Burner
2. Medium Burner
3. Large Burner
4. Small Burner

Voltage: 230 V
Frequency: 50 Hz