Periscope Installation (For use with dryer vent to wall vent 
mismatch):

Part Number 4396037 - 0 in. (0 cm) to 18 in. (45.72 cm) 
mismatch

Part Number 4396011 - 18 in. (45.72 cm) to 29 in. (73.66 cm) 
mismatch

Part Number 4396014 - 29 in. (73.66 cm) to 50 in. (127 cm) 
mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.

Determine Vent Length

1. Select the route that will provide the straightest and most 

direct path outdoors. Plan the installation to use the fewest 
number of elbows and turns. When using elbows or making 
turns, allow as much room as possible. Bend vent gradually to 
avoid kinking. Avoid 90º turns.

2. Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

If a combination of rigid and flexible metal vent is used.

Recommended hood styles are shown here.

1. Louvered hood style
2. Box hood style

The angled hood style (shown following) is acceptable.

The same length of vent can be used with any of the 3 exhaust 
hoods shown. 

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and 
increased energy usage.

3. Determine the number of elbows you will need.

NOTE: Do not use vent runs longer than specified in the Vent 
Length Chart.

When using only one type of metal vent:

Use the following chart to help you determine your maximum 
vent length based on the number of 90° turns or elbows you 
will need and the type of vent (rigid and/or flexible metal) you 
will use. 

When using a combination of rigid and flexible metal vent:

Use the following charts to help you determine your maximum 
vent length based on the number of 90° turns or elbows you 
will need.

Determine the number of elbows or turns you will need.

Determine the length of the fully extended flexible metal 
vent you will use. Find the column that has the nearest 
number of feet to what you will be using.

Match the number of turns or elbows with the length of the 
fully extended flexible metal vent you will use to find the 
maximum length of rigid metal vent you can use.

     4"
(10.2 cm)

      4"
(10.2 cm)

2

1

   4"

(10.2 cm)

2½"

(6.4 cm)

Vent Length Chart

Number of 90º 
turns or elbows

Rigid metal vent

Flexible metal vent

0

120 ft (36.6 m)

40 ft (12.2 m)

1

110 ft (33.5 m)

37 ft (11.3 m) 

2

100 ft (30.5 m)

33 ft (10.1 m)

3

 90 ft (27.4 m)

30 ft (9.1 m)

4

 80 ft (24.4 m)

27 ft (8.2 m)

5

 70 ft (21.3 m)

23 ft (7.0 m)

Vent Length Chart - 0 ft (0 m) to 10 ft (3.0 m)

No. of 
turns or 
elbows

Length of Flexible Metal Vent

0 ft
(0 m)

1-5 ft
(.3-1.5 m)

6-10 ft
(1.8-3.0 m)

0

120 ft
(36.6 m)

105 ft
(32.0 m)

90 ft
(27.4 m)

Length 
of 
Rigid 
metal
vent

1

110 ft
(33.5 m)

95 ft
(29.0 m)

80 ft
(24.4 m)

2

100 ft
(30.5 m)

85 ft
(25.9 m)

70 ft
(21.3 m)

3

90 ft
(27.4 m)

75 ft
(22.9 m)

60 ft
(18.3 m)

4

80 ft
(24.4 m)

65 ft
(19.8 m)

50 ft
(15.2 m)

5

70 ft
(21.3 m)

55 ft
(16.8 m)

40 ft
(12.2 m)

Summary of Contents for 8535899

Page 1: ...ma de ventilación 22 Instalación de las patas niveladoras 22 Nivelación de la secadora 23 Conexión del ducto de escape 23 Cómo invertir el cierre de la puerta opcional 23 Complete la instalación 24 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to ...

Page 2: ...alled or stored in an area where it will be exposed to water and or weather Check code requirements Some codes limit or do not permit installation of the dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector Installation Clearances The location must be large enough to allow the dryer door to open fully Dryer Dimensions Most installations require a minimum...

Page 3: ...h clothes dryers The kit should contain A UL approved 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL approved strain relief If your outlet looks like this 4 wire receptacle 14 30R Then choose a 4 wire power supply cord w...

Page 4: ...en yellow 6 Hole below terminal block opening WARNING Fire Hazard Use a new UL approved 30 amp power supply cord Use a UL approved strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals ...

Page 5: ...f 3 wire connections Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA Type 14 30R A UL listed 120 240 volt minimum 30 amp dryer power supply cord 4 wire connection Power Supply Cord 4 wire direct A fused disconnect or circuit breaker box 4 wire connection Direct Wire 3 wire re...

Page 6: ...n screw 3 wire connection Power Supply Cord Use where local codes permit connecting cabinet ground conductor to neutral wire 1 Loosen or remove center terminal block screw 2 Connect neutral wire white or center wire of power supply cord to the center silver colored terminal screw of the terminal block Tighten screw 3 Connect the other wires to outer terminal block screws Tighten screws 4 Tighten s...

Page 7: ...nsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Optional 3 wire connection Use for direct wire or power supply cord where local codes do not permit connecting cabinet ground conductor to neutral wire 1 Remove center terminal block screw 2 Remove appliance ground wire green with yellow stripes from external ground connector screw Connect appliance g...

Page 8: ... 5 cm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes etc If using an existing vent system clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint Replace any plastic or metal foil vent with rigid metal or flexible metal vent PlanVentSystem Typical exhaust installations Typical installations vent the d...

Page 9: ...ll need NOTE Do not use vent runs longer than specified in the Vent Length Chart When using only one type of metal vent Use the following chart to help you determine your maximum vent length based on the number of 90 turns or elbows you will need and the type of vent rigid and or flexible metal you will use When using a combination of rigid and flexible metal vent Use the following charts to help ...

Page 10: ...ench to adjust the legs up or down and check again for levelness NOTE It might be necessary to level the dryer again after it is moved into its final position ConnectVent 1 Using a 4 in 10 2 cm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Make sure the vent ...

Page 11: ...door hinge slot is over screws Slide door up so screws are in bottom of slots Tighten screws Insert and tighten top screws in hinges 10 Remove door strike plug 2 Insert the door strike you removed in Step 8 in hole and secure with screw Insert door strike plug in original door strike hole and secure with screw 11 Close door and check that door strike aligns with door catch 3 If needed slide door c...

Page 12: ...lesión grave Todos los mensajes de seguridad le dirán el peligro potencial le dirán cómo reducir las posibilidades de sufrir una lesión y lo que puede suceder si no se siguen las instrucciones Su seguridad y la seguridad de los demás es muy importante Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodoméstico Lea y obedezca siempre todos los mensajes de segurid...

Page 13: ...a Se aceptan puertas tipo persianas con aberturas de ventilación equivalentes También se debe considerar espacio adicional para otro electrodoméstico que le acompañe Requisitos de instalación adicionales para las casas rodantes Esta secadora es apropiada para instalaciones en casas rodantes La instalación debe ajustarse al Estándar de seguridad y construcción de casas fabricadas Título 24 CFR Part...

Page 14: ...e anillo o de horquilla y con protector de cables aprobado de UL El cable de suministro eléctrico de 3 hilos de por lo menos 4 pies 1 22 m de largo deberá tener 3 hilos de cobre sólido de calibre 10 y coincidir con un receptáculo de 3 hilos tipo NEMA 10 30R Si hace la conexión con cableado directo El cable de suministro eléctrico debe ser igual al del suministro eléctrico de 4 alambres o de 3 alam...

Page 15: ...tura del bloque de terminal Peligro de Incendio Use un cable de suministro eléctrico nuevo de 30 amperes con aprobación UL Use un protector de cables con aprobación UL Desconecte el suministro eléctrico antes de hacer las conexiones eléctricas Conecte el alambre neutro el blanco o el del centro al terminal central plateada El alambre de tierra el verde o el no aislado se debe conectar con el conec...

Page 16: ...Un contacto de 4 hilos Tipo NEMA 14 30R Un cordón de suministro eléctrico para secadora aprobado de UL de 120 240 voltios mínimo y 30 amperios Conexión de 4 hilos Cordón de suministro eléctrico Cable directo de 4 hilos Un desconectador con fusible o una caja de disyuntor Conexión de 4 hilos Cable directo Contacto de 3 hilos Tipo NEMA 10 30R Un cordón de suministro eléctrico para secadora aprobado ...

Page 17: ...el hilo de tierra NEUTRO antes de moverlo al tornillo central del bloque de terminal 2 Tornillo central de color plateado del bloque de terminal 3 Hilo verde amarillo del mazo de conductores 3 Conecte el hilo de tierra verde o desnudo del cable de suministro eléctrico al tornillo del conector de tierra externo Apriete el tornillo 4 Coloque el extremo del hilo neutro en forma de gancho hilo blanco ...

Page 18: ...ta exterior Doble los extremos de los hilos para formar un gancho Al conectar el hilo al bloque de terminal coloque el extremo del hilo en forma de gancho debajo del tornillo del bloque de terminal con el gancho mirando hacia la derecha Apriete y junte el extremo en forma de gancho y apriete el tornillo 1 Afloje o saque el tornillo central del bloque de terminal 2 Coloque el extremo en forma de ga...

Page 19: ... central de color plateado del bloque de terminal Apriete el tornillo 3 Conecte los otros hilos a los tornillos exteriores del bloque de terminal Apriete los tornillos 4 Apriete los tornillos del protector de cables 5 Introduzca la lengüeta de la cubierta del bloque de terminal en la ranura del panel posterior de la secadora Asegure la cubierta con el tornillo de sujeción 6 Conecte un hilo de tier...

Page 20: ...oedores e insectos a la casa La capota de ventilación debe estar por lo menos a 12 pulg 30 5 cm de distancia del piso o de cualquier objeto que pudiese estar en el trayecto del ducto de escape como flores rocas o arbustos etc Si se usa un sistema de ventilación existente limpie la pelusa que está en toda la longitud del sistema y asegúrese de que la capota de ventilación no esté obstruida con pelu...

Page 21: ...entilación depende de El tipo de ducto de escape metal rígido o metal flexible El número de codos utilizados Si se usa una combinación de ductos de metal rígidos y flexibles los estilos recomendados de capotas de ventilación se ilustran aquí El estilo de capota de ventilación angular que se ilustra a continuación es aceptable Se puede usar la misma longitud del ducto de escape con cualquiera de la...

Page 22: ...a consola Coloque la secadora cuidadosamente sobre el cartón 3 Examine las patas niveladoras Localice la marca en forma de diamante 4 Atornille con la mano las patas en los orificios de las patas Use una llave de tuercas para terminar de atornillar las patas hasta que la marca en forma de diamante no quede visible 5 Coloque un poste esquinal de cartón debajo de cada una de los 2 esquinales posteri...

Page 23: ...s del gabinete 4 Use un destornillador pequeño de boca plana para quitar con cuidado los cuatro tapones 4 de los orificios de la bisagra que están en el lado izquierdo del gabinete Introduzca los tapones en los agujeros de la bisagra en el lado derecho del gabinete 5 Introduzca los tornillos en los agujeros inferiores en el lado izquierdo del gabinete Atorníllelos por la mitad Coloque la puerta de...

Page 24: ...ue si tiene todas las herramientas 3 Deshágase de todos los materiales de embalaje 4 Revise la localización final de la secadora Asegúrese de que el ducto de escape no esté aplastado o retorcido 5 Verifique si la secadora está nivelada Vea Nivelación de la secadora 6 Enchufe en un contacto con conexión a tierra Conecte la energía 7 Quite la película protectora azul que está en la consola y cualqui...

Reviews: