Page 8
3.
Assemble
3/4" U.L.-listed strain relief
(U.L. marking on strain relief) into the
hole below terminal block opening.
Tighten strain relief screws just enough
to hold the two clamp sections
together. Install power supply
cord/cable through the strain relief.
For a grounded, cord-connected
appliance —
GROUNDING INSTRUCTIONS:
This appliance must be grounded. In
the event of malfunction or
breakdown, grounding will reduce
the risk of electric shock by providing
a path of least resistance for electric
current.
If using a power supply cord, the plug
must be plugged into an appropriate
outlet that is properly installed and
grounded in accordance with all
local codes and ordinances.
WARNING - Improper connection of
the equipment-grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded. Do not modify the plug
provided with the appliance - if it will
not fit the outlet, have a proper outlet
installed by a qualified electrician.
For a permanently connected
appliance —
GROUNDING INSTRUCTIONS:
This appliance must be connected to
a grounded metal, permanent wiring
system; or an equipment-grounding
conductor must be run with the
circuit conductors and connected to
the equipment-grounding terminal or
lead on the appliance.
Complete installation following
instructions for your type of
connection:
• Four-wire (recommended method)
• Three-wire (if four-wire is not
available)
1.
Disconnect the power supply.
2.
Remove hold-down screw
and terminal block cover.
Power supply cord
Direct wire
This dryer is manufactured with the
cabinet-ground conductor
connected to the NEUTRAL (center) of
the wiring harness at the terminal
block. If local codes do NOT permit
this type of connection, use “Four-
wire connection” instructions.
dryer
cabinet
strain relief
screws
strain
relief
clamp
sections
terminal
block
cover
hold-
down
screw
tab
external ground
conductor screw
Fire Hazard
Use a new UL approved 30
ampere power supply cord.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or
center wire) to center terminal
(silver).
Ground wire (green or bare wire)
must be connected to green
ground connector.
Connect remaining 2 supply
wires to remaining 2 terminals
(gold).
Securely tighten all electrical
connections.
Failure to do so can result in
death, fire, or electrical shock.
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or
center wire) to center terminal
(silver).
Ground wire (green or bare wire)
must be connected to green
ground connector.
Connect remaining 2 supply
wires to remaining 2 terminals
(gold).
Securely tighten all electrical
connections.
Failure to do so can result in
death, fire, or electrical shock.
WARNING
WARNING
6.
Make electrical connection.
Use a new UL-approved power supply
cord rated 240-volt min., 30 amperes
and marked for use with a clothes
dryer.