Model # 7LIECH-SSF-WL: Page 12

Descaling 

If you use mineral water you will need to descale your hot water tank.

When mineral water is used, calcium deposits will block passageways in the hot water tank. 
This blockage can be observed by the gradual slow down in the flow rate.

Descaling Solutions

There are 2 substances proven to remove calcium deposits efficiently. They are:
1. White vinegar used for cooking.
2. Lemon acid in powdered form, used by beverage makers and bakeries.  

Depending on the frequency of decalcification treatments, please use the following proportions 
of substances.

1. White Vinegar:
- For descaling once every 3 months, use 2 cups (500 ml) of white vinegar with 2.5 liters of hot 

water.

- For descaling once every 6 months, use a mixture of 6 cups of white vinegar with 2 liters of hot 

water.

- For descaling once every year, use 12 cups of white vinegar and 1 liter of hot water. 
-For descaling less frequently than once a year, use undiluted white vinegar.

2. Lemon Acid:
- For descaling once every 3 months, use a mixture of 1 oz. of powdered lemon acid and 3.5 

liters of hot water.

- For descaling once every 6 months, use a mixture of 2 oz. of powdered lemon acid and 3.5 

liters of hot water.

- For descaling once every year, use a mixture of 4 oz. of powdered lemon acid and 3.5 liters 

hot water.

- For descaling less frequently than once a year, use a mixture of 5 oz. of powdered lemon acid 

and 3.5 liters hot water.

Descaling Procedure

1. Fill a bucket or empty 5-gallon water bottle with the descaling solution of your choice. For 

proportions, refer to the instructions above.  Choose substance and quantity in accordance 
with the frequency of your treatments.

2. Attach or insert the probe to the bucket/bottle.

Summary of Contents for 7LIECH-SSF-WL

Page 1: ...H SSF WL 5M010993XN01 E S SAVE THIS MANUAL FOR FUTURE USE Stainless Steel Hot and Ice Cold Water Cooler Model No 7LIECH SSF WL For service call 1 855 594 4755 or e mail Whirlpool electrotemp com USERS MANUAL ...

Page 2: ...hot water and efficient energy use TABLE OF CONTENTS Safety Precautions Electrical Requirements Safety Precautions Product Features Key Information for Future Use Specifications Parts Features Unpacking and Assembly Installation Operation Cleaning Prior To Initial Use Proper Care Descaling Troubleshooting Limited Warranty 2 3 4 4 5 5 6 6 7 9 10 14 15 IMPORTANT Do NOT Return Dispenser To Store If y...

Page 3: ...or WARNING These words mean You can be killed or seriously injured if you don t immediately follow the instructions SAVE THESE INSTRUCTIONS State of California Proposition 65 Warnings WARNING This product contains one or more chemicals known to the State of California to cause cancer WARNING This product contains one or more chemicals known to the State of California to cause birth defects or othe...

Page 4: ... for assistance PRODUCT FEATURES Model 7LIECH SSF WL Page 4 Congratulations You have chosen a technology advanced state of the art water cooler The refrigeration system on this cooler cools the cold water by internal evaporator of commer cial design flat forms the ice around it This feature is called an Ice Bank It allows for ice cold water and keeps the water temperature consistently cold however...

Page 5: ...allon 80 C 92 C 176 F 197 6 F 27 5W cm 28 6D cm 92 7H cm 10 8W inch 11 3D inch 36 5H inch 12 5 Kg 27 6 Ibs Front Back IMPORTANT Do NOT Return Dispenser To Store If you have a question or problem please contact 1 855 594 4755 for assistance Model 7LIECH SSF WL Page 5 2 4 6 7 5 13 3 10 11 8 12 1 9 Bottle Probe Hot Water Control Child Safety Latch Cold Water Control Hot Water Tap Cold Water Tap Drip ...

Page 6: ...ts into the holes marked 2 3 4 and 5 3 Install the foot without a nut into the hole marked as 1 4 Carefully stand the cooler up 5 To level the cooler first adjust feet 1 4 and 5 then 2 and 3 6 For proper stability all feet must be in contact with the floor 1 2 3 4 5 Foot with nut Foot without nut Excessive Weight Hazard Use two or more people to move and install bottles Failure to do so can result...

Page 7: ...ottle cap and neck using a soft cloth and warm soapy water then rinse after wards 3 Lift the bottle and insert onto the probe Apply slight pressure until the plug inside the cap pushes in and the bottle is seated Water will begin to flow into the reservoirs causing air bubbles to form in the bottle 4 Plug the cord into a properly grounded wall outlet 5 Turn energy saving switch on back of dispense...

Page 8: ...t dispenses water quickly To avoid splashes hold the cup as close to the tap as possible 2 Press the right control downward to start dispensing water 3 Release the control once desired fill level is achieved Dispensing Hot Water 1 Hot water available 15 20 minutes after set up 2 Red arrow and target holes in the grill indicate positioning of your container for dispensing hot water 3 Hold your cont...

Page 9: ...arger bucket under the drain plug in the rear of the dispenser Remove drain cap and drain plug Reminder Place the drain cap drain plug and screw in a safe location so that they will not be lost 7 Once unit has completed draining empty the bucket and return it to under the drain cap 8 Replace drain cap and drain plug 9 Wipe the inside of the reservoir with a soft cloth 10 Fill the reservoir with 1 ...

Page 10: ...n the dishwashing solution Hard to remove spots can be rubbed away using stainless steel wool Rub in horizontal direction Then clean with cloth soaked in the dishwashing solution Wipe dry with clean cloth Apply a little bit of mineral oil unscented baby oil and rub it in evenly Cleaning Cold Reservoir and Water Lines Perform Every 3 months or whenever an off taste occurs Time Required 15 minutes N...

Page 11: ...Place a 2 gallon or larger bucket under the drain plug in the rear of the dispenser Remove drain cap and silicon plug to drain Reminder Place drain cap and drain plug in a safe location so they are not lost 14 Remove the cleaning mixture from reservoir by dispensing it from both taps into a pitcher 15 Replace drain cap and drain plug 16 Rinse system by repeating steps 12 15 above but this time usi...

Page 12: ...ot water For descaling once every 6 months use a mixture of 6 cups of white vinegar with 2 liters of hot water For descaling once every year use 12 cups of white vinegar and 1 liter of hot water For descaling less frequently than once a year use undiluted white vinegar 2 Lemon Acid For descaling once every 3 months use a mixture of 1 oz of powdered lemon acid and 3 5 liters of hot water For descal...

Page 13: ...he back of the cooler B Remove the screw C Remove the clear silicone drain plug and allow water to drain out D Reattach the drain plug and plastic cap before proceeding 8 Fill the bucket bottle with tap water and place into the machine 9 Plug the cooler back into the wall close the door and wait for 10 minutes 10 Dispense water from both cold and hot faucets until smell from cleaning substances di...

Page 14: ...rmation of calcium deposits is to only use distilled or reverse osmosis water To clean deposits in water cooler refer to Proper Care and Descaling section Cooler is not operating Ensure that water cooler power cord is properly connected to a working outlet Water is leaking Replace water bottle Most common cause is a cracked bottle Call 1 855 594 4755 for assistance Push buttons are stuck and or fa...

Page 15: ... and routine maintenance on the dispenser as set out in the User s Manual In addition the Limited Warranty does not cover damages to the finish such as scratches dents discoloration or rust after purchase The Limited Warranty is in lieu of all other express warranties Vendor disclaims all warranties for products that are purchased from seller other than authorized retailers or distributors AFTER T...

Page 16: ...al Mart English 图号 5M010993XN00 E S 技术要求 1 尺寸 215 279mm 2 单色印刷 3 产品符合RoHS要求 4 批量生产前一定要样品确认 不得擅自更改图纸 5 我已经根据DRC 包材设计可靠性检查表核对过 设计 工程审核 业务审核 品质审核 批准 修订 修改内容 修改人 修订表 01 1 第8页热水部分you更改为your 2 第2页 第7页 第11页危险警告标贴改回原来的 李雪玲 2015 08 17 ...