8
Electrical Connection
Power Supply Cord
Electrical Connection Options
1.
Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to steps 1-2 on
page 9 for power supply cord strain relief:
then steps 3-6 for 4-wire Power Supply
Cord Connection section. Then, go to
Venting Requirements.
3-wire direct connection:
Go to steps
1-2 on page 11 for direct wire strain relief:
then steps 3-7 for 3-wire Direct Wire
Connection section. Then go to Venting
Requirements.
4-wire direct connection:
Go to steps
1-2 on page 10 for direct wire strain relief:
then steps 3-8 for 4-wire Direct Wire
Connection section. Then go to Venting
Requirements.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to steps 1-2 on
page 9 for power supply cord strain relief:
then steps 3-5 for 3-wire Power Supply
Cord Connection section.
Then go to Venting Requirements.
NOTE:
If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
3-wire Connection” section. This connection may be
used with either a power supply cord or a direct wire
connection.
Direct Wire
D
A
B
C
C
E
F
2.
Remove terminal block cover
Before you start, disconnect power. Remove hold-down
screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw
E. Neutral ground wire
F. Hole below terminal block cover