COMPONENT CHECK GUIDE
S.NO COMPONENT NATURE OF
TESTING PROCEDURE
REMEDY
PROBLEM
1
Plug and
Machine Gives
Check for proper earthing to
Inform customer
socket
shock
which the machine is connected
to correct for
using multimeter.
proper earthing
Check voltage between
Phase & Neutral
Phase & Earth
both should be equal.
Check continuity between
Neutral & Earth
If found to be short Earthing is
defective
2
Fuse
Blown
Using multimeter check continuity
between both the ends.
Replace the fuse
3
Power cord
Discontinuity
Check for proper continuity
between plug side and machine
side also check for short circuit
between wires
Replace power
cord
4
Capacitor
Not functioning
WARNING:
DISCHARGE
BEFORE
HANDLING
Check the capacitor with the
multimeter in continuity mode.
The meter should first read ohms
and gradually the needle should
swing back to infinity Ohms. It
indicates a good capacitor and
any thing other than this is
defective.
Replace the
capacitor
5
Wash Motor
Does not run
Check the winding resistance
using a multimeter between wires
BLACK & BLUE 37.6 Ohms
approx. BLACK & YELLOW 42.6
Ohms. If the resistances are not
as per the given value it could be
short or open
Replace the
wash motor