TROUBLESHOOTING cont...
System hasn’t detected any current change
when turning on or off fiber box.
• Make sure fiber box is connected properly.
• Manually change the output status (on/off)
of fiber box and cycle through all possible
speeds.
• Reset spa pack.
• If error does not clear, call your local dealer
and schedule a service call.
System hasn’t detected any current change
when turning the fan ON or Off.
• Make sure the fan is connected properly.
• Manually change the output status (on/off).
• Reset spa pack.
• If error does not clear, call your local dealer
and schedule a service call.
System relearn error
• Every time a low-level option is changed, the
system must “relearn” currents associated to
each output/load. During this learning process,
the device connected to OUT8 (direct output,
no relay) must be disconnected
if it draws
more than 0.4 amp
. If it doesn’t, system will
report a SC error code.
• Once the load is correctly disconnected, user
needs to restart the learning process by
pressing either Select or Change key on the
in.xm display panel (in.scan interface).