STROBE SPECIFICATIONS

INPUT VOLTAGE  - - - - - - - - - - - - - - 12.8 VDC ± 20%
INPUT CURRENT

2 STROBES - - - - - - - - - - - 4.5 AMPS (TYP)
4 STROBES - - - - - - - - - - - 9 AMPS (TYP)
6 STROBES - - - - - - - - - - - 13.5 AMPS (TYP)

INPUT POWER - - - - - - - - - - - - - - - - 230 WATTS (TYP)
ANODE VOLTAGE- - - - - - - - - - - - - - 450 VDC (MAX)
TRIG. VOLTAGE - - - - - - - - - - - - - - - 150 VDC (MIN)
ENERGY PER FLASH - - - - - - - - - - - 7.9 / 3.8 / 3.8 / 3.8
FLASHRATE - - - - - - - - - - - - - - - - - - 140 CFPM
OUTPUT POWER - - - - - - - - - - - - - - 22.5 WATTS (TYP)
(PER OUTLET)

HALOGEN SPECIFICATIONS

INPUT VOLTAGE  - - - - - - - - - - - - - - 12.8 VDC ± 20%
INPUT CURRENT

2 LAMPS - - - - - - - - - - - - - 4.5 AMPS (TYP)
4 LAMPS - - - - - - - - - - - - - 9 AMPS (TYP)

INPUT POWER - - - - - - - - - - - - - - - - 230 WATTS (TYP)
OUTPUT VOLTAGE- - - - - - - - - - - - - INPUT VOLTAGE - 1V
ON TIME - - - - - - - - - - - - - - - - - - - - 125 mS (TYP)
OFF TIME- - - - - - - - - - - - - - - - - - - - 125 mS (TYP)
FLASHRATE - - - - - - - - - - - - - - - - - - 120 DFPM ±5%
OUTPUT POWER - - - - - - - - - - - - - - 50 WATTS (MAX)
(PER OUTLET)

DIAGNOSTIX

DIAGNOSTIX

15A

-

H

AL.

1-4

15A

-

H

AL.

5-8

15A

-

STR.

1-4

15A

-

STR.

5-8

CONTROL

SERIAL

C

OMMUNICA

TIONS

DIAGNOSTICS

H1

H2

H3

H4

H6

H5

H7

H8

S1

S2

S3

S4

S6

S5

S7

S8

12V BATTERY

CUSTOMER SUPPLIED

45 AMP FUSE

BLK

RED

®

HALOGEN

TRAFFIC ADVISOR

STROBE

FTF4 DIP SWITCH

SETTINGS:

1

0N

2

OFF

3

ON

4

OFF

5

OFF

Summary of Contents for FastTrax FTF4

Page 1: ...or currents Properly protect and use caution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or veh...

Page 2: ...between the fuse block and the positive battery terminal WARNING All customer supplied wires that connect to the positive terminal of the battery must be sized to supply at least 125 of the maximum o...

Page 3: ...and H8 This will insure that the lightheads are connected to their proper power supply port A lighthead s identity is determined by what power supply port they are to be connected to Note Before the...

Page 4: ...and down through the C pillar until it enters the trunk area of the vehicle In the trunk route the cable bundle towards the ISP8HS The basic cable path is as shown Repeat this entire procedure using...

Page 5: ...alf 1 wide area on either side of the tape will have to be prepared This area is called the bonding surface Remove the FastTrax housing from the vehicle 3 The bonding surface must be completely clean...

Page 6: ...e control head on the proposed mounting location Using a pencil or other suitable tool scribe the mounting surface where the holes are to be drilled CAUTION As mounting the control head will require d...

Page 7: ...ROBES 4 5 AMPS TYP 4 STROBES 9 AMPS TYP 6 STROBES 13 5 AMPS TYP INPUT POWER 230 WATTS TYP ANODE VOLTAGE 450 VDC MAX TRIG VOLTAGE 150 VDC MIN ENERGY PER FLASH 7 9 3 8 3 8 3 8 FLASHRATE 140 CFPM OUTPUT...

Page 8: ...alogens H1 H4 Halogen H2 H3 Halogens H5 H8 X X ON X ON ON X X X X ON X X X Not Used Not Used Diagnostix LED Indicators DIAGNOSTIX HALOGEN STROBE PB 1 PB 2 PB 3 PB 4 PB 5 PB 6 Push Buttons 2 3 Control...

Page 9: ...OUSING AS MOLDED ASS Y 6 STROBE 2 HAL RAW 01 0683334 04 20 02 0342292 01 ASS Y REFLECTOR DUAL HALOGEN 12V 27H 1 1 21 13 062C40 16J 6 SCREW GROMMET 242 160502 70 10 10 A R A R TAPE VHB DOUBLE STICK BLA...

Reviews: