Page 7 of 9
A Note On Painting the FastTrax™ Housing...
If painting or re-painting
your FastTrax housing, it is
important to keep in mind
the following information:
•
Do not apply paint or
primer to any of the
black-colored area
immediately adjacent
to the clear outer lens!
•
Do not apply paint or
primer to the under-
side of the housing.
•
Make sure that all sur-
faces to be painted
have been primed
using primer that is
suitable for ABS plas-
tic.
•
Be sure to include the
leading edges (mate-
rial thickness) in your
painting surfaces.
STROBE SPECIFICATIONS
INPUT VOLTAGE - - - - - - - - - - - - - - 12.8 VDC ± 20%
INPUT CURRENT
2 STROBES - - - - - - - - - - - 4.5 AMPS (TYP)
4 STROBES - - - - - - - - - - - 9 AMPS (TYP)
6 STROBES - - - - - - - - - - - 13.5 AMPS (TYP)
INPUT POWER - - - - - - - - - - - - - - - - 230 WATTS (TYP)
ANODE VOLTAGE- - - - - - - - - - - - - - 450 VDC (MAX)
TRIG. VOLTAGE - - - - - - - - - - - - - - - 150 VDC (MIN)
ENERGY PER FLASH - - - - - - - - - - - 7.9 / 3.8 / 3.8 / 3.8
FLASHRATE - - - - - - - - - - - - - - - - - - 140 CFPM
OUTPUT POWER - - - - - - - - - - - - - - 22.5 WATTS (TYP)
(PER OUTLET)
HALOGEN SPECIFICATIONS
INPUT VOLTAGE - - - - - - - - - - - - - - 12.8 VDC ± 20%
INPUT CURRENT
2 LAMPS - - - - - - - - - - - - - 4.5 AMPS (TYP)
4 LAMPS - - - - - - - - - - - - - 9 AMPS (TYP)
INPUT POWER - - - - - - - - - - - - - - - - 230 WATTS (TYP)
OUTPUT VOLTAGE- - - - - - - - - - - - - INPUT VOLTAGE - 1V
ON TIME - - - - - - - - - - - - - - - - - - - - 125 mS (TYP)
OFF TIME- - - - - - - - - - - - - - - - - - - - 125 mS (TYP)
FLASHRATE - - - - - - - - - - - - - - - - - - 120 DFPM ±5%
OUTPUT POWER - - - - - - - - - - - - - - 50 WATTS (MAX)
(PER OUTLET)
DIAGNOSTIX
DIAGNOSTIX
15A
-
H
AL.
1-4
15A
-
H
AL.
5-8
15A
-
STR.
1-4
15A
-
STR.
5-8
CONTROL
SERIAL
C
OMMUNICA
TIONS
DIAGNOSTICS
H1
H2
H3
H4
H6
H5
H7
H8
S1
S2
S3
S4
S6
S5
S7
S8
12V BATTERY
CUSTOMER SUPPLIED
45 AMP FUSE
BLK
RED
®
HALOGEN
TRAFFIC ADVISOR
STROBE
FTF4 DIP SWITCH
SETTINGS:
1
0N
2
OFF
3
ON
4
OFF
5
OFF