Whelen Engineering Company E-969 Installation & Operating Manual Download Page 1

Page 1

©1995 Whelen Engineering Company Inc.
Form No.13056E (051906)

51 Winthrop Road
Chester, Connecticut 06412-0684
Phone: (860) 526-9504
Internet: www.whelen.com
Sales e-mail: [email protected]
Customer Service e-mail: [email protected]

Mass Notification

®

ENGINEERING COMPANY INC.

For warranty information regarding this product, visit  

www.whelen.com/warranty

      WARNING:

 This product can expose you to chemicals including Lead which is known to the State of California to cause cancer and birth defects or

other reproductive harm. For more information go to www.P65Warnings.ca.gov.

E-969 ENCODER

Installation & Operating

Manual

UP

DOWN

WARNING

TONES

ROTATING

DIRECTION

VOICE

MESSAGES

TEST

& MISC

8

7

9

0

#

ALL

5

4

6

2

1

3

SEND

E-969  - -  STAND BY MODE
MONDAY

01:45:02

ON/OFF

PRECHECK

RESET

COMMAND GROUP

SIREN ADDRESS

CALL KEYS

SCROLL

®

E-969

C2

C1

C4

C3

Summary of Contents for E-969

Page 1: ...product visit www whelen com warranty WARNING This product can expose you to chemicals including Lead which is known to the State of California to cause cancer and birth defects or other reproductive...

Page 2: ...use of a Whelen Engineering Company Inc Model E 969 Encoder Prior to reading this manual or using this product you should be familiar with Whelen Engineering Company s family of High Power Voice and...

Page 3: ...tained herein is proprietary to the Whelen Engineering Company Inc No part of this manual may be reproduced recorded or stored in a retrieval system or transmitted in any form without prior permission...

Page 4: ...Call Key page 11 Programming Remote Inputs for One Shot activation page 14 Programming Remote Inputs for Call Key activation page 16 Time Of Day Function programmed for One Shot activation page 18 Ti...

Page 5: ...gh Time Of Day inputs or Remote Activation inputs as described in a later section The liquid crystal display LCD is a 2 line by 24 character configuration The display is backlit for easy reading in lo...

Page 6: ...e 5 MSG 6 Activates Digital Voice Message 6 MSG 7 Activates Digital Voice Message 7 MSG 8 Activates Digital Voice Message 8 MSG 9 Activates Digital Voice Message 9 MSG 10 Activates Digital Voice Messa...

Page 7: ...send the selected command Pressing the SEND key will send the command There is no second chance Call Keys There are 8 Call Keys Call Keys 1 4 are located on the right side of the keypad as shown C1 is...

Page 8: ...and C4 The other four call keys C5 C6 C7 and C8 can only be accessed by way of the two Remote Inputs and two Time of Day activations The intended use of a Call Key is to simplify and minimize the use...

Page 9: ...By display Call Key Use the numeric keypad to select the Call Key number 0 7 and press PRECHECK to enter Next use the numeric keypad to select a two digit sequence number 00 99 and press PRECHECK to e...

Page 10: ...s RESET to return to the Stand By display or an UP or DOWN arrow to scroll to a different parameter Precheck Digit Use the numeric keypad to select a value 0 9 Press PRECHECK to enter Press RESET to r...

Page 11: ...e display will read PROGRAM ENCODER CALL KEY 5 Press the PRECHECK button The display will read ENTER KEY KEY SEQ 6 Select the desired call key number 1 8 to be programmed by pressing number key in the...

Page 12: ...CLOCKWISE COUNTER CLOCKWISE Press TEST MISC for SILENT TEST TEST CLEAR STROBE ON STROBE OFF For SILENT TEST the display will read ENTER CMD KEY 1 SEQ 00 SILENT TEST 11 Press the PRECHECK button The d...

Page 13: ...SEQ 00 SILENT TEST 1001 015 SEC 15 Press the PRECHECK button The display will read SAVE DATA KEY 1 SEQ 00 SILENT TEST 1001 015 SEC 16 Press the PRECHECK button The display will read PROGRAM ENCODER CA...

Page 14: ...ay will read PROGRAM ENCODER REMOTE INPUT 1 5 Press the PRECHECK button The display will read ENTER CMD REM INPUT1 COMMAND 6 Press the desired COMMAND GROUP button and scroll to desired command Note P...

Page 15: ...g the buttons in the SIREN ADDRESS key pad location For All Call address the display will read ENTER ADDR REM INPUT1 NOON TEST For 1001 address the display will read ENTER ADDR REM INPUT1 SILENT TEST...

Page 16: ...ll read PROGRAM ENCODER CLOCK 4 Press the UP arrow four times The display will read PROGRAM ENCODER REMOTE INPUT 1 5 Press the PRECHECK button The display will read ENTER CMD REM INPUT1 COMMAND 6 Pres...

Page 17: ...8 Press the PRECHECK button The display will read SAVE DATA REM INPUT1 CALL KEY 4 9 Press the PRECHECK button The display will read PROGRAM ENCODER REMOTE INPUT 1 10 Press the RESET button to exit pro...

Page 18: ...HECK button The display will read PROGRAM ENCODER CLOCK 4 Press the UP arrow two times The display will read PROGRAM ENCODER TIMED TRANS 1 5 Press the PRECHECK button The display will read ENTER TIME...

Page 19: ...SILENT TEST TEST CLEAR STROBE ON STROBE OFF For NOON TEST the display will read ENTER CMD TT1 12 00 00 NOON TEST SMTWTFS 9 Press the PRECHECK button The display will read ENTER ADDR TT1 12 00 00 NOON...

Page 20: ...activate Days with lower case letters are days configured not to activate For Monday Wednesday Friday activations the display will read ENTER SKIPS TT1 12 00 00 NOON TEST 1001 sMtWtFs 13 Press the PRE...

Page 21: ...utton The display will read PROGRAM ENCODER CLOCK 4 Press the SCROLL UP arrow two times The display will read PROGRAM ENCODER TIMED TRANS 1 5 Press the PRECHECK button The display will read ENTER TIME...

Page 22: ...ead ENTER SKIPS TT1 12 00 00 CALL KEY 4 SMTWTFS 11 Select the days for no activation by using the SIREN ADDRESS buttons Note Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Days...

Page 23: ...Page 23 13 Press the PRECHECK button The display will read PROGRAM ENCODER TIMED TRANS 1 14 Press the RESET button to exit programming...

Page 24: ...ENCODER FRIDAY 16 00 02 3 Press the PRECHECK button The display will read PROGRAM ENCODER CLOCK 4 Press the PRECHECK button The display will read PROGRAM ENCODER ENTER TIME DAY 5 Enter the day of the...

Page 25: ...sing the SIREN ADDRESS buttons Example 9 00PM will be entered as 21 00 00 The display will read PROGRAM ENCODER ENTER TIME MON 21 00 00 7 Press the PRECHECK button The display will read PROGRAM ENCODE...

Page 26: ...ire per Ground input depending on the use of the inputs The pinouts are as follows Pin Signal 1 Push To Talk Output 2 Push To Talk Output 3 Audio Output 4 Audio Output 5 Squelch In Input 6 Ground 7 Ch...

Page 27: ...tiometer for 50 of max deviation Repeat this step as needed to adjust the level 8 Set the microphone level Plug the microphone into the MIC jack Key up the microphone and adjust the MIC VOL potentiome...

Page 28: ...6 C Storage temperature 2 C to 6 C Humidity 0 95 non condensing Audio 2 wire 600 transformer balanced adjustable Control Normally open relay for Push To Talk Contact rating 1 2 A 120 VAC 1 A 24 VDC S...

Reviews: