background image

Page 2

WARNING:

The strobe power supply is a high voltage device.

Do not remove strobe tubes or dismantle strobe light head
assembly while in operation. Wait 10 minutes after turning off
power before starting work or trouble shooting.

IMPORTANT:

All customer supplied wires, that connect to the

positive (+) terminal of the battery, must be sized to supply at
least 125% of the maximum operating current, and fused at the
battery to carry the load.

MAGNET

SPLIT LOCK
WASHER

PHILLIPS TYPE
AB SCREW

CIGAR PLUG
AND CORD

FOAM GASKET

(MMK)

GROMMET

TIE KNOT

IN CORD

TO ACT
AS STRAIN
RELIEF

11

SMOOTH

GROOVED

BLACK

RED

POWER

SUPPLY

ASS’Y.

CRIMP WIRES TO CUSTOMER SUPPLIED 2 CONDUCTOR CABLE. RED / POSITIVE
DC VOLTAGE. BLACK / NEGATIVE GROUND. CUSTOMER SUPPLIED SINGLE
THROW (SPST) SWITCH MAY BE USED TO CONTROL ON/OFF FUNCTION.

WHEN INSERTING FLASH TUBE
ASSEMBLY INTO STROBE POWER
SUPPLY ASSEMBLY, ALIGN THE
3 PRONGS ON THE FLASH TUBE
ASSEMBLY WITH THE SLOTS
ON THE STROBE POWER
SUPPLY ASSEMBLY.

IMPORTANT:

SEE PAGE 3

FOR ASSEMBLY
INSTRUCTIONS.

13

3

12

10

1

15

7

8

9

2

PERFORATED CIRCLE IN BASE GASKET. REMOVE OUTER

PART TO FIT DIAMETER OF ALUMINUM BASE FOR PERM. MTG.

18

20

17

14

4

5

IMPORTANT: The outer surfaces of this product may be cleaned
with mild soap and water. Use of any other chemicals may void
product warranty. Do not use a pressure washer.

INPUT VOLTAGE

12.8V & 25.6V NOM.

1.7A & .85A AVERAGE

21.5 WATTS (TYP)

72 CFPM @ 100mS

115 DFPM @ 170mS

150-370-150 SFPM @ 3S

(1) COMET & (4) SINGLE

6.4/1.6/1.6/1.6/1.6 JOULES

15 WATTS (TYP)

INPUT CURRENT

INPUT POWER

CometFlash®

DoubleFlash

RapidRandom

ActionFlash™

ENERGY

OUTPUT POWER

FLASHRATE:

SPECIFICATIONS:

Summary of Contents for 2015 Series

Page 1: ...onnections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment simultaneously to insure that they operate free of interference from other com...

Page 2: ...EGATIVE GROUND CUSTOMER SUPPLIED SINGLE THROW SPST SWITCH MAY BE USED TO CONTROL ON OFF FUNCTION WHEN INSERTING FLASH TUBE ASSEMBLY INTO STROBE POWER SUPPLY ASSEMBLY ALIGN THE 3 PRONGS ON THE FLASH TUBE ASSEMBLY WITH THE SLOTS ON THE STROBE POWER SUPPLY ASSEMBLY IMPORTANT SEE PAGE 3 FOR ASSEMBLY INSTRUCTIONS 13 3 12 10 1 15 7 8 9 2 PERFORATED CIRCLE IN BASE GASKET REMOVE OUTER PART TO FIT DIAMETER...

Page 3: ...er FLANGE MOUNT 1 INCH NPT PIPE MOUNT or PERMANENT MOUNT The threading for a 1 inch NPT pipe mounting is precast in the cast aluminum base FLANGE MOUNT 1 Select the mounting location taking into consideration visibility of the strobe light flash mounting surface and ease of wiring 2 Using the base gasket ITEM 5 as a template mark the 3 mounting holes and center wire access hole onto mounting surfa...

Page 4: ...bly to the mounting studs with enclosed self tapping screws Slightly bend the transistor on the power supply away from the transistor mounting boss Slip the Cho Therm insulator behind the transistor with the hole directed towards the top see figure 4 A Position the top of the Cho Therm insulator against the circuit board of the power supply assembly making sure that some of it shows below the tran...

Reviews: