Page 2
WARNING:
The strobe power supply is a high voltage device.
Do not remove strobe tubes or dismantle strobe light head
assembly while in operation. Wait 10 minutes after turning off
power before starting work or trouble shooting.
IMPORTANT:
All customer supplied wires, that connect to the
positive (+) terminal of the battery, must be sized to supply at
least 125% of the maximum operating current, and fused at the
battery to carry the load.
MAGNET
SPLIT LOCK
WASHER
PHILLIPS TYPE
AB SCREW
CIGAR PLUG
AND CORD
FOAM GASKET
(MMK)
GROMMET
TIE KNOT
IN CORD
TO ACT
AS STRAIN
RELIEF
11
SMOOTH
GROOVED
BLACK
RED
POWER
SUPPLY
ASS’Y.
CRIMP WIRES TO CUSTOMER SUPPLIED 2 CONDUCTOR CABLE. RED / POSITIVE
DC VOLTAGE. BLACK / NEGATIVE GROUND. CUSTOMER SUPPLIED SINGLE
THROW (SPST) SWITCH MAY BE USED TO CONTROL ON/OFF FUNCTION.
WHEN INSERTING FLASH TUBE
ASSEMBLY INTO STROBE POWER
SUPPLY ASSEMBLY, ALIGN THE
3 PRONGS ON THE FLASH TUBE
ASSEMBLY WITH THE SLOTS
ON THE STROBE POWER
SUPPLY ASSEMBLY.
IMPORTANT:
SEE PAGE 3
FOR ASSEMBLY
INSTRUCTIONS.
13
3
12
10
1
15
7
8
9
2
PERFORATED CIRCLE IN BASE GASKET. REMOVE OUTER
PART TO FIT DIAMETER OF ALUMINUM BASE FOR PERM. MTG.
18
20
17
14
4
5
IMPORTANT: The outer surfaces of this product may be cleaned
with mild soap and water. Use of any other chemicals may void
product warranty. Do not use a pressure washer.
INPUT VOLTAGE
12.8V & 25.6V NOM.
1.7A & .85A AVERAGE
21.5 WATTS (TYP)
72 CFPM @ 100mS
115 DFPM @ 170mS
150-370-150 SFPM @ 3S
(1) COMET & (4) SINGLE
6.4/1.6/1.6/1.6/1.6 JOULES
15 WATTS (TYP)
INPUT CURRENT
INPUT POWER
CometFlash®
DoubleFlash
RapidRandom
ActionFlash™
ENERGY
OUTPUT POWER
FLASHRATE:
SPECIFICATIONS: