background image

 
 
 
1.  Zone page or all call 
     page cannot be  
     accessed 

 

 
 
 
1.  Telephone system must have touchtone (DTMF)  
     dialing. 
 
2.  Check presence and polarity of voltage on  
     -24VDC and GND terminals on TB4 

 
 
 
2.  No background music. 

 

 
 
 
1.  Verify unit has released from last page. 
 
2.  Check program source, and adjust its volume 
     control, as desired. 
 
3.  Check presence of music audio input at "T" in 
     and "R" in and if necessary also at the music  
     source. 
 
4.  Check presence of music audio input at MUSIC 
     terminals on TB4, and if necessary also at  
     speaker amplifier, or central or zone amplifier  
     inputs. 

 
 
 
3.  No sound or low page 
     volume. 

 

 
 
 
1.  Check presence and level of audio input at Tip 
     and Ring terminals on TB4, and if necessary  
     also at the CO port. (or the Audio Page Port) 
 
2.  Check presence and level of audio at the zone 
     AUDIO output terminals on TB1, TB2, and TB3.  
     If necessary also at speaker amplifier inputs,  
     and central or zone amplifier inputs. 

 
 
 
4.  The page alert tone is 
     too high or too low. 

 

 
 
 
1.  Set the page alert Tone Volume Control in the  
     ZC-9, to the desired level. 

 
 
 
5.  Talkback does not 
     function properly. 

 

 
 
 
1.  Check to insure that the zone INH and GND 
     terminals on TB1, TB2, and TB3 are properly  
     connected to the Wheelock TBM-101 Talkback  
     Speakers and/or TBH-104 Talkback Horns. 
 
2.  Check for proper programming of the zone's  
     One-way/Talkback select switch. 
 
3.  Refer to the Wheelock TBM-101 and/or TBH- 
     104 installation instructions. 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

P81835 E 

Sheet 11 of 12 

Limited Warranty 

Error! Bookmark not defined.

 

 

Summary of Contents for ZC-9

Page 1: ...ne if it is causing the malfunction If the equipment is determined to be malfunctioning its use shall be discontinued until the problem has been corrected APPLICATION INFORMATION WARNING ANY MATERIAL EXTRAPOLATED FROM THIS DOCUMENT OR FROM WHEELOCK MANUALS OR OTHER DOCUMENTS DESCRIBING THE PRODUCT FOR USE IN PROMOTIONAL OR ADVERTISING CLAIMS OR FOR ANY OTHER USE INCLUDING DESCRIPTION OF THE PRODUC...

Page 2: ...itch as described in CHART 3 FUNCTION CHOICES PER SYSTEM 1 or 2 Central Amplifiers 1 One Central Amplifier For both paging and background music Paging in any zone will mute music in all zones 2 Two Central Amplifiers One for paging and one for background music Music is muted only in the zone paged CHART 3 SYSTEM PROGRAMMABLE FUNCTION The speech direction function is programmed on a per zone basis ...

Page 3: ...e s CHART 5 SYSTEM AMPLIFIER CONFIGURATIONS FUNCTIONS AND MUSIC MUTE OPERATION The application diagrams in Figures 1 thru 4 show the four basic system configurations of the ZC 9 all of which are possible with the appropriate programming switch selections FIGURE 1 One Central Amplifier One amplifier for both paging and background music System uses speakers with built in line matching transformers F...

Page 4: ...fier paging system may be zoned and then expanded by adding amplified speakers or zone amplifiers With the appropriate programming switch selections the following are some examples of mixed system possibilities A FIGURE 1 and FIGURE 3 B FIGURE 1 and FIGURE 4 C FIGURE 2 and FIGURE 3 D FIGURE 2 and FIGURE 4 E FIGURE 3 and FIGURE 4 NOTE In mixed systems the different amplifier configurations must be ...

Page 5: ... is designed for indoor surface wall mounting near the telephone system Remove the ZC 9 cover from the base containing the PC board assembly by removing the screw on each side of the unit Two keyholes and two circular holes are provided in the base for easy installation A diagram for mounting screw hole locations is given in FIGURE 5 Recommended screw sizes are 6 8 or 10 screws Be sure to use moun...

Page 6: ... LEVEL MAX PER ZONE CENTRAL AMPLIFIER SELECTED 25W 25V or 70W 70V central amplifier output See Note 2 OPERATING TEMPERATURE RANGE 0 to 55 degrees C OPERATING HUMIDITY RANGE 0 to 85 RH ZONE CONTROL ACCESS See Note 1 Press CO line button or touchtone dial number assigned to page PAGE ZONE 1 Dial 1 PAGE ZONE 2 Dial 2 PAGE ZONE 3 Dial 3 PAGE ZONE 4 Dial 4 PAGE ZONE 5 Dial 5 PAGE ZONE 6 Dial 6 PAGE ZON...

Page 7: ...of 12 WIRING INSTRUCTIONS SEE FIGURE 7 1 Make sure 24VDC power supply is disconnected from the 115VAC power source 2 Connect Tip and Ring from the telephone system to TB4 terminals 5 and 6 respectively 3 Connect the background music source to TB4 terminals 1 and 2 ...

Page 8: ...tral Amplifier select switches for each of groups 1 2 and 3 as required See switch symbol 1 If a group is using a zone amplifier speaker amplifiers or Wheelock Talkback Modules then slide that group s switch to the left If a group is using a central amplifier then slide that group s switch to the right 2 Set the Central Amplifier Select Switch as required See Switch symbol 2 If one central amplifi...

Page 9: ...FIGURE 7 INSTALLATION PROGRAMMING AND VOLUME ADJUSTMENT DIAGRAM P81835 E Sheet 9 of 12 PAGE PORT INSTALLATION INSTRUCTIONS ...

Page 10: ...oth in the telephone receiver and in all selected zones 7 To conclude a page simply hang up the telephone handset VOLUME CONTROL ADJUSTMENT INSTRUCTIONS 1 In the ZC 9 set the music volume control to minimum If the system uses two central amplifiers then set the ZC 9 music volume control midway between minimum and maximum 2 In the ZC 9 set the page and tone volume controls midway between minimum an...

Page 11: ...nput at Tip and Ring terminals on TB4 and if necessary also at the CO port or the Audio Page Port 2 Check presence and level of audio at the zone AUDIO output terminals on TB1 TB2 and TB3 If necessary also at speaker amplifier inputs and central or zone amplifier inputs 4 The page alert tone is too high or too low 1 Set the page alert Tone Volume Control in the ZC 9 to the desired level 5 Talkback...

Page 12: ... SPECIFICATION ABUSE ACCIDENT OR OTHER OPERATING CONDITIONS BEYOND WHEELOCK S CONTROL WHEELOCK DOES NOT WARRANT THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE OR THAT THE SOFTWARE WILL MEET ANY OTHER STANDARD OF PERFORMANCE OR THAT THE FUNCTIONS OR PERFORMANCE OF THE SOFTWARE WILL MEET THE USER S REQUIREMENTS WHEELOCK SHALL NOT BE LIABLE FOR ANY DELAYS BREAKDOWNS INTERRUPTI...

Reviews: