Wheelock TPA-100-B Installation Instructions Manual Download Page 1

 

273 Branchport Avenue 
Long Branch, N.J.  07740 
(732)  222-6880 

 

INSTALLATION INSTRUCTIONS 

MODEL TPA-60-B/TPA-100-B 

PAGING AMPLIFIERS 

 
 
 
GENERAL APPLICATION INFORMATION: 

Wheelock models TPA-60-B and TPA-100-B Paging Amplifiers are output rated at 60 watts RMS and 100 watts RMS 
respectively. 
 
These amplifiers afford a choice of five different inputs:  two low impedance microphone inputs, one telephone paging 
input, and two high impedance auxiliary inputs.  Three input channels allow three of these inputs to be used actively at 
one time:  one microphone input, a choice of a telephone paging input or a second microphone input, and a choice of 
either one of two auxiliary inputs.  Note that the auxiliary input (i.e., background music, tone generator, etc) will 
automatically be soft muted whenever a telephone page is generated or a microphone is used.  After completion of the 
page, the music will rapidly return to its original level. 
 
A built-in limiter circuit (ALC) compensates for the varying voice levels and paging styles of the people who have access 
to telephone paging or a microphone.  The limiter maintains rated output without distortion. 
 
The amplifiers feature individual input volume controls, as well as a master volume control, individual treble and bass 
controls, a low-cut horn protect switch, two input selector switches, an illuminated power on switch, an internal ALC 
(limiter) ON-OFF switch, an internal mute ON-OFF switch, a peak level indicator, and a line output jack. 
 
Both models operate from 120 volts, 60Hz and have a power consumption of 180 watts (TPA-60-B) and 240 watts (TPA-
100-B).  The units have a circuit breaker on the AC line input as well as a thermal breaker for overload protection on the 
output.  The AC circuit breaker is manually resettable.  IN THE EVENT THE CIRCUIT BREAKER DOES NOT RESET, 
HAVE THE TROUBLE INVESTIGATED BY AN AUTHORIZED SERVICE TECHNICIAN OR RETURN UNIT TO THE 
FACTORY. 
 
 

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, 

DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. 

 
 
UNPACKING: 
The amplifier was carefully checked before leaving the factory.  Inspect shipping container and unit carefully for indication 
of improper handling.  If the unit has been damaged, make an immediate claim to the carrier. 
 
MOUNTING INSTRUCTIONS: 
The amplifier is provided with a set of universal mounting brackets to facilitate either rack or surface wall mounting.  
Remove the 8 screws (4 on either side) holding the cover to the chassis.  Choose the mounting required (rack or surface 
wall), and insert screws through the universal mounting bracket and back into the cover/chassis holes as shown in 
Figures 1 and 2. 
 

CAUTION:

 

THESE DEVICES ARE NOT INTENDED FOR USE IN HAZARDOUS LOCATIONS AS 
DEFINED BY THE NATIONAL ELECTRICAL CODE (NEC) AND BY THE NATIONAL FIRE 
PROTECTION ASSOCIATION (NFPA). 

 

P82423 C 

Sheet 1 of 10 

RACK MOUNTING 

 
 

Summary of Contents for TPA-100-B

Page 1: ... switches an illuminated power on switch an internal ALC limiter ON OFF switch an internal mute ON OFF switch a peak level indicator and a line output jack Both models operate from 120 volts 60Hz and have a power consumption of 180 watts TPA 60 B and 240 watts TPA 100 B The units have a circuit breaker on the AC line input as well as a thermal breaker for overload protection on the output The AC c...

Page 2: ...d has a three prong plug which should be plugged into a three wire grounded electric outlet It is very important to maintain the amplifier ground for safe and trouble free operation If there is no grounded electric outlet connect a wire from the GND terminal on the OUTPUT terminal strip to a water or steam pipe P82423 C Sheet 2 of 10 TECHNICAL SPECIFICATIONS ...

Page 3: ...RED NEON POWER ON RED LED PEAK LEVEL 12 PROTECTION AC LINE RESETTABLE CIRCUIT BREAKER AND THERMAL OVERLOAD PROTECTION ON OUTPUT 13a TREBLE CONTROL 10 5 dB TO 10 5 dB 12 KHz 13b BASS CONTROL 10 5 dB TO 10 5 dB 100 Hz 14 LO CUT SWITCH 6 dB 250 Hz 15 AUTOMATIC LIMITER FOR PAGING 3 dB OUTPUT LEVEL MAINTAINED WITHOUT CLIPPING EVEN WHILE EXCEEDING RATED INPUT LEVEL UP TO 20 dB 16 AUTOMATIC MUTE OPERATIO...

Page 4: ...lephone paging or low impedance LO Z microphone input channel INPUT CONNECTIONS FIGURE 3 AUXILIARY INPUTS FIGURE 4 To connect an FM tuner CD player tape player tone generator or any other line level program source i e mic line mixer to either the AUX 1 or AUX 2 input jacks on the back panel use a single conductor shielded cable terminated in a standard RCA type phono plug AUX 1 AUX 2 is a high imp...

Page 5: ...REQUIREMENT IS THE SUMMATION OF THE WATTAGE TAP SELECTIONS OF ALL SYSTEM SPEAKERS AND HORNS OUTPUT CONNECTIONS FIGURE 5 LINE OUTPUT FIGURE 6 The LINE OUTPUT jack on the back panel can be used to cascade amplifiers including amplified speakers or Wheelock PRM 150 preamplifiers or connect send signal to a tape recorder The signal on this output is a line level mix of the amplifier s input channels U...

Page 6: ...FIGURE 8 A tape recorder can be connected to record live programs microphone inputs or all of the amplifiers activity all inputs CONNECTING A TAPE RECORDER FIGURE 8 P82423 C Sheet 6 of 10 TELEPHONE PAGING ACCESS CONNECTIONS AUDIO PAGE PORT ...

Page 7: ...ns for internal control settings and adjustments FIGURE 9B UNUSED CO LINE TRUNK PORT OR STAND ALONE TELEPHONE FIGURE 9C CAUTION CONNECT ONLY TO PBX INCORPORATING ISOLATION FROM TELECOM NETWORK ATTENTION RACCORDER SUELEMENT A UNSYSTEME PBX INDEPENDANT DU RESEAU DE TELECOMMUNICATION P82423 C Sheet 7 of 10 OPERATION ...

Page 8: ...ting straight up Dot 6 Set at factory in Dot 6 position TEL MIC 1 SELECTOR SWITCH Switch to TEL position for telephone paging or switch to MIC 1 position when using a microphone Set at factory in the TEL position AUX 1 AUX 2 SELECTOR SWITCH Switch to either AUX 1 or AUX 2 position depending upon which of 2 program source inputs are utilized Set at factory in AUX 1 position HORN PROTECT LO CUT SWIT...

Page 9: ... from the top front of the amplifier the switches are located on a 4 segment switch block in the lower left hand section of the power PC Board which is mounted to the chassis base ALC LIMITER AND MUTE ON OFF SWITCHES FIGURE 11 P82423 C Sheet 9 of 10 ALC LIMITER ON OFF SWITCH For live program applications i e house of worship auditoriums etc it is often desirable to defeat the ALC limiter function ...

Page 10: ...N ON POSITION MAINTENANCE CAUTION THERE ARE NO USER REPLACEABLE PARTS WITHIN THE UNIT HAVE ALL INTERNAL SERVICING DONE BY A QUALIFIED TECHNICIAN LIMITED WARRANTY Refer to Wheelock s Terms and Conditions of sale WARNING ANY MATERIAL EXTRAPOLATED FROM THIS DOCUMENT OR FROM WHEELOCK MANUALS OR OTHER DOCUMENTS DESCRIBING THE PRODUCT FOR USE IN PROMOTIONAL OR ADVERTISING CLAIMS OR FOR ANY OTHER USE INC...

Reviews: