P83541 F
Sheet 3 of 6
is functioning properly.
ACKNOWLEDGEMENT
CONTACT YOUR SERVICE REPRESENTATIVE IMMEDIATELY.
To Acknowledge a Trouble Condition:
MANUAL OPERATION
To Sound Evacuation Tone:
MICROPHONE OPERATION
ZONE DISARRANGEMENT
FOR ADDITIONAL INFORMATION:
FOR SAPE, REFER TO O&M-3/105411
1. Slide the AUTOMATIC/MANUAL switch DOWN to the
When the GREEN "NORMAL" LED is ON, the system
When the YELLOW "TROUBLE" LED is ON there is a
FAULT in the system which MUST BE CORRECTED.
IF THE YELLOW "TROUBLE" LIGHT IS ON, THIS UNIT MAY NOT BE ABLE TO
PROVIDE EMERGENCY ANNOUNCEMENT CAPABILITIES AND COULD RESULT
IN PROPERTY DAMAGE, SERIOUS INJURY OR DEATH TO YOU AND/OR
OTHERS. IN THE EVENT THE "TROUBLE" LIGHT IS ON, YOU SHOULD
1. Momentarily depress the TROUBLE ACKNOWLEDGE button.
This will only silence the internal sounder and any external
trouble condition with the yellow "TROUBLE" LED on and
the system trouble contact will remain in the trouble
position until all trouble conditions have been corrected.
trouble signaling devices. The system will remain in the
1. Hold the microphone within 2 inches of mouth and
2. Deliver message. Activation of the microphone will
IT WILL ALSO PUT THE UNIT INTO A TROUBLE CONDITION.
ANY ZONE DISARRANGEMENT WILL SILENCE IT'S RESPECTIVE ZONE.
1. Slide the zone disarrangement switch down to the
2. To override zone disarrangement, slide the
DISARRANGEMENT
ACKNOWLEDGE
DISARRANGEMENT
DISARRANGEMENT
DISARRANGEMENT
ALL-CALL
press the push-to-talk switch on microphone.
deliver the message to all circuits.
DISARRANGEMENT position.
WARNING
ZONE SELECT/ALL-CALL switch to ALL-CALL
MANUAL position.
NORMAL
TROUBLE
ZONE 4
ZONE 3
ZONE 2
ZONE 1
WARNING
MANUAL
TROUBLE
AUTOMATIC
ZONE SELECT
FOR RSAPE, REFER TO O&M-5/107384
POWER AT THE POWER SOURCE, THEN
TERMINALS.
RECONNECT BATTERY POWER AT THE BATTERY
MODULAR PC BOARDS INSIDE WITHOUT
THEN DISCONNECT AC POWER AT THE
POWER SOURCE.
DISCONNECTING
RECONNECTING
BATTERY POWER AT THE BATTERY TERMINALS,
THIS UNIT FIRST. FAILURE TO DO SO MAY
DO NOT ATTEMPT TO REMOVE OR REPLACE
RESULT IN DAMAGE TO THE PC BOARDS.
DISCONNECTING ALL POWER SOURCES TO
BEFORE REMOVING THIS PANEL:
- FIRST RECONNECT AC
- FIRST DISCONNECT
CAUTION
PLUG LOCATIONS
(TYPICAL 4 PER COVER)
COVER
LOCATIONS
Figure 3:
WIRING DIAGRAM:
1.
See Figure 4 for wiring diagram.
2.
See Figure 5 for terminal block wiring designations.
MOTHER BOARD
(SAMB)
SPL
SPL
ALL CALL
ZONE 2 AUDIO
ZONE 1 AUDIO
ALL CALL IN
PWR IN
AUDIO IN
Z1
Z2
Z3
Z4
COM
24V
SUPERVISED CIRCUIT
UL LISTED 10K OHM 1W
EOLR RESISTOR
SPL
ALL CALL IN
PWR IN
AUDIO IN
Z1
Z2
Z3
Z4
Figure 4:
CAUTION
: "POWER IN" terminals should be connected to the system power on the left side of the motherboard. Do no connect
to Remote Mic Power above "ALL CALL" terminals.