Wheelock PRM-150 Installation Instructions Download Page 2

P81537 G 

Sheet 2 of 5 

 

UP TO 150 SPEAKER AMPLIFIERS

T-IN

R-IN

PRM-150

R-OUT

T-OUT

AUDIO 
PAGE
PORT
600 (OHM)

EKSU
 OR
PABX

GND  -24V

T

R

GND  -24V

GND  -24V

 

 

Figure 2. 

 
One-way paging with a PRM-150 connected directly to a 600 OHM CO or page port.  If the telephone system provides one or more 
600 OHM page ports, then a PRM-150 is required for each port. 
 

UP TO 150 SPEAKER

T-IN

R-IN

PRM-150

R-OUT

T-OUT

UNUSED

C.O.

PORT

EKSU
 OR
PABX

T

R

GND  -24V

GND  -24V

GND  -24V

GND  -24V

T-OUT

R-OUT

PRM-150

R-IN

T-IN

GND  -24V

GND  -24V

T-OUT

R-OUT

PRM-150

R-IN

T-IN

AMPLIFIERS PER ZONE

ZONE CONTROL

ZC-3

WHEELOCK

ZONE 2

ZONE 1

ZONE 3

R

T

 

 

Figure 3. 

 
One-way paging with a Wheelock ZC-3 Zone Control.  When connecting over 10 amplified speakers to the ZC-3, it may be necessary 
to connect Wheelock PRM-150 line preamplifiers to the zone outputs.  Depending upon system configuration (i.e., quantity of 
speakers, length of wire runs, and audio output level of the host telephone system), it may also be necessary to use PRM-150's with 
less than 10 amplified speakers.  24VDC connection (not shown) is required for each PRM-150, and the ZC-3. 
 

 

UP TO 150 SPEAKER AMPLIFIERS

T-IN

R-IN

PRM-150

R-OUT

T-OUT

UNUSED

C.O.

PORT

EKSU
 OR
PABX

GND  -24V

R

T

GND  -24V

GND  -24V

SPARE

(-)

(+)

RPS-2406

POWER

SUPPLY

 

Figure 4. 

 
One-way single zone paging from an unused CO port.  This application is used only when external talk battery is required, otherwise, 
use Figure 2. 

Summary of Contents for PRM-150

Page 1: ...ities equipment and operations procedures where such action is reasonably required in the operation of its business and is not inconsistent with the rules and regulations of the Federal Communications Commission Do not attempt to repair or modify this equipment Repairs to this product will be performed by Wheelock Inc 273 Branchport Ave Long Branch NJ 07740 in accordance with Wheelock s Inc publis...

Page 2: ...1 ZONE 3 R T Figure 3 One way paging with a Wheelock ZC 3 Zone Control When connecting over 10 amplified speakers to the ZC 3 it may be necessary to connect Wheelock PRM 150 line preamplifiers to the zone outputs Depending upon system configuration i e quantity of speakers length of wire runs and audio output level of the host telephone system it may also be necessary to use PRM 150 s with less th...

Page 3: ...ms SPECIFICATIONS Table 1 Nominal Input Voltage 24VDC Input Voltage Range 18VDC to 28VDC Maximum Input Current at 24VDC 35mA Audio Input Level T IN and R IN 15dBM 0 1V RMS TO 10dBM 2 4V RMS Input Impedance 600 Ohms Output Impedance 4 Ohms Output Gain T OUT and R OUT 0 to 15dBM Maximum into 4 Ohm Load Output Drive Capability 150 Speaker Amplifiers Maximum Frequency Response 70Hz to 14kHz INSTALLATI...

Page 4: ...er Amplifier volume controls as required TROUBLE SHOOTING CONDITION CHECK 1 No audio output to Speaker Amplifiers 1 Volume control turned up clockwise 2 Check presence and polarity of 24VDC and GND 3 Check audio presence and level on T OUT and R OUT at PRM 150 and if necessary also at the Speaker Amplifiers 4 Check audio presence and level on T IN and R IN at PRM 150 and if necessary at the audio ...

Page 5: ...DAMAGE RESULTING FROM MISAPPLICATION IMPROPER SPECIFICATION ABUSE ACCIDENT OR OTHER OPERATING CONDITIONS BEYOND WHEELOCK S CONTROL WHEELOCK DOES NOT WARRANT THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE OR THAT THE SOFTWARE WILL MEET ANY OTHER STANDARD OF PERFORMANCE OR THAT THE FUNCTIONS OR PERFORMANCE OF THE SOFTWARE WILL MEET THE USER S REQUIREMENTS WHEELOCK SHALL NOT B...

Reviews: