P O W E R
page 9 – 6
TV80 / Sep 03
TECH NOTE: To insure proper power sequencing in systems using an Event
Computer, we recommend that the SPS-180 Event Computer Power Supply be
connected to the same AC power circuit as the SPS-40 Console Power Supply.
Further, if you have failsafe power supply pairs and have connected each SPS-40
to its own separate AC power circuit, as recommended elsewhere in this manual,
we recommend that you connect one SPS-180 to each of those circuits. If this is
not done and the power to the SPS-180(s) is temporarily interrupted, the console’s
Smart Select displays could display inaccurate information about the channel
sources after the SPS-180(s) restart, requiring the operator to toggle the source
on each of the affected channels to correct the display error. No other ill effects
will be produced.
Smart Select Cage
To power the TV-80’s separate rackmounted Smart Select
®
Cage,
which performs the actual audio switching for the console’s optional
input module preselector panels, a supplied cable runs from the power
supply chassis rear 8-pin connector to a 10-pin connector on the back of
the Smart Select
®
Cage chassis. If you have ordered a failsafe configura-
tion, there will be two supplies; each feeds one connector on the back of
the cage.
If the system employs two Smart Select® cages, an FSI-B unit is used
to split the supply voltage signals to feed both cages. A cable connects the
center connector of the FSI-B to the power supply. A second shorter cable
connects the cage (either connector) to one of the remaining connectors
on the FSI-B. A third (short) cable
connects the other cage to the FSI-B.
A failsafe configuration with two cages
employs two FSI-B units. The first one
is wired as described, while the second
one is used to connect the remaining
connectors on the cages to the second
supply.
Left rear view of rackmount Smart Select Cage showing
dual 10-pin power connectors. If dual failsafe SPS-180
power supplies have not been ordered, only one connector
will be used.
!
Smart Select Cage
End
Power Supply
End
E
D
F
H
PIN
1
2
3
4
PIN
8-pin Connector
Male
10-pin Connector
Female
Power Supply End
Smart Select Cage End
G
A
C
B
5
VIO
GRN
BRN
YEL
ORG
BLK
BLU
RED
PS Cable Pinout
VIO
GRN
BRN
YEL
ORG
Phantom
6
BLK
7
BLU
8
RED
Digital Ground
Digital Ground
Analog Ground
-V in
+V in
TV80 / Dec 04
Summary of Contents for TV-80
Page 1: ...TV 80 Audio Console TECHNICAL MANUAL 600 Industrial Drive New Bern North Carolina USA 28562 ...
Page 103: ...A P P E N D I C E S TV80 Sep 98 page A 8 APPENDIX II Factory Leg Set Assembly ...
Page 106: ...A P P E N D I C E S TV80 Sep 98 page A 11 APPENDIX III Torpey Clock Display ...
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......