background image

30

Instruction

maintenance, power line surge, lightning damage, modification, or service by anyone

other than a Factory Service center or other Authorized Servicer, or damage that is

attributable to acts of God.

2) THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED UNDER "LIMITED
WARRANTY COVERAGE". THE WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT, OR
ARISING OUT OF ANY BREACH OF THIS WARRNTY. (As examples, this excludes
damages for lost time, cost of having someone remove or re-install an installed unit if
applicable, travel to and from the service, loss of or damage to media or images, data or
other recorded content. The items listed are not exclusive, but are for illustration only.)
3) PARTS AND SERVICE, WHICH ARE NOT COVERED BY THIS LIMITED WARRANTY,
ARE YOUR RESPONSIBILITY.

Summary of Contents for SX-MX17

Page 1: ...1 4x4 HDMI2 0 Matrix Support 4K 60hz YUV4 4 4 18Gbps HDR Operating Instruction...

Page 2: ...ing or adjusting this product Please keep this manual for future reference SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical s...

Page 3: ...nterface 12 8 5 preset application 14 8 6 setup interface 15 8 7 Query information interface 18 9 RS232 Control 20 9 1 Open CommUart Assistant 20 9 2 Comport setting 20 9 3 Enter Port Command in Send...

Page 4: ...up to 192KHZ Support analog and S PDIF audio extraction Support EDID management and EDID study Support firmware updating through USB port 2 Package Contents 1 1x HDMI Matrix 2 1x 12V 2A DC power suppl...

Page 5: ...reset 5 UP short press to up 6 LOCK long press to lock long press again to unlock when lock all button is unworkable except for lock button 7 MENU press to main menu interface or return to the previou...

Page 6: ...g and Operating 1 Connect source devices to input ports of the matrix 2 Connect HDMI output ports to TV or other HDMI sink devices 3 Optional connect RS232 cable from PC RS232 port 4 Optional connect...

Page 7: ...1 4 5 All outputs select INPUT Y a Press all button b Press INPUT Y button Y means 1 to 4 of the inputs then INPUT Y switched to ALL OUTPUTS 6 Turn off output channel 7 PTP button Mirror all inputs a...

Page 8: ...ll change according to the switching input and skip automatically if no input signal 8 Panel Control Description 8 1 Video switch operation Signal switching includes 4 switching channels which can be...

Page 9: ...and down button to choose Switching press ENTER to enter the next sub menu press the up and down button to select Output1 4 All means all output Swtching the bottom color of the selected output turn...

Page 10: ...nd down button to select On Off press ENTER button to enter the next sub menu Press up and down button to select output1 4 All means all output the bottom color of the selected output turn to white pr...

Page 11: ...11 Operating Instruction 8 3 Audio control interface There are 2 sub menus in audio control interface Line out De Embed both are default open...

Page 12: ...on control De Embed able to set the output audio for both analog and SPDIF audio can select any one Channel audio output or mute Operation select Audio in main menu and press ENTER button press up and...

Page 13: ...s up and down button to select Input 1 All means all input press ENTER button to enter the next sub menu press up and down button to select Default1 the bottom color of the selected turn to white pres...

Page 14: ...l Preset control interface has three sub menu Call scene Save scene Clear scene Operation select Preset in main menu and short press ENTER button to enter preset interface able to call save and clear...

Page 15: ...etting 4 options for baud rate setting 9600 19200 57600 115200 The default serial port is 115200 Below example is setting baud rate to 9600 Operation select Setup in main menu and press ENTER button 2...

Page 16: ...elect DHCP setting press ENTER to enter the next sub menu press up and down button to select On press ENTER to open DHCP to allocate IP address automatically 8 6 3 Reboot Reboot device default is NO O...

Page 17: ...IP address can t be factory rest when under common 2 Factory All factory set for video switch EDID audio setting preset and device name Eg factory all operation select Setup in main menu and press ENT...

Page 18: ...evice name and version information IP interface query device IP address MAC address and DHCP status Operation select INFO in main menu and press ENTER button press up and down button to select System...

Page 19: ...19 Operating Instruction...

Page 20: ...rt Command in Send options 9 4 Command List 1 All commands start with 2 _ the underline cannot omit 3 Command head Parameter and target need to add one SPACE The following table is only an example Ple...

Page 21: ...igured with the device mainly to ensure that the computer and the device are set in the same network segment 1 Open the network control center and set the computer s IP address 2 Choose to use Static...

Page 22: ...1 04 eg switching input1 to output 4 Click 04 04 firstly then click 01 2 input 01 04 means HDMI input 1 4 3 OFF close output channel click OFF to close output channel Click ON to close this function T...

Page 23: ...k output1 HDMI color will change and TV only with video but no audio Re click to tu rn on audio 2 Click output1 4 De Embed turn off audio extraction function also turn off SPDIF and a nalog audio at t...

Page 24: ...out3 11 Copy HDMI out4 12 Copy input1 13 Copy input2 14 Copy input3 15 Copy input4 16 Default is empty need save EDID to device to take effect don t support power off memory 1 EDID Information show E...

Page 25: ...dress same as client IP will re login web interface If unable to refresh automatically then need to resubmit form manually Dynamic IP Click DHCP switch DHCP On IP address assigned by router and turn t...

Page 26: ...or partial function Factory all Click to reset device totally Reboot will not clear user parameter Factory common will not clear Network and Preset parameter Factory all will reset to default totally...

Page 27: ...ing with encrypted firmware it may fail to burn or can t work normally Should decrypt firmware before burning Burning ways as below 11 1 MCU application layer upgrade Connect unit to PC with usb cable...

Page 28: ...n 11 2 Web Upgrade Connect unit to PC with usb cable from micro usb port open software UART_ISP_V1 6 exe select correct USB port set baud rate 115200 type in F0 in PORT and select PATH then click UPDA...

Page 29: ...arts 2 Year Labor 90 Days which starts with the date of original purchase Limited Warranty period at its option either a repair your product with new or refurbished parts or b replace it with a new of...

Page 30: ...LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRNTY As examples this excludes damages for lost time cost of having someon...