20
Operating Instruction
9. RS232 Control
9.1 Open CommUart Assistant
.
9.2 Comport setting:
Choose correct COM port that connect to PC in parameter configuration area
Baud Rate:
115200 bps(Default)
Parity:
None
Data Bit:
8 bit
Stop Bit:
1 bit
9.3 Enter Port Command in Send options.
9.4.Command List
1).All commands start with “#”
2).“_” the underline cannot omit.
3) Command head,Parameter and target need to add one “SPACE”.
The following table is only an example.Please refer to the list of instructions.
Type
Format
Value
Regulation
Command head
#cmd
without
Explain
Can be used to search command,after receiving command, the system will
feedback all open command format fields
Example1
#cmd
Search all open command