background image

Manual                          AMP 4200                                                       

 

Valid for                        

111-425-04-001-00

 

 

Version (modifications reseverd) 

21.02.2022 

Seite 11 of 17 

 

10.2.3. Power Saving 
 

 

 
If “Auto” is selected as “Power Saving”, the amplifier goes into stand-by mode after an extended period 
(approx. 20 min.) without an input signal. 
 
You can use the 

trigger function

 e.g. if you use a control signal via a beamer (home cinema). 

 
 

 

 
 

Note: 

As soon as an input signal is present again, the amplifier is reactivated. 
 
 
 
 
 
 
 
 
 

Summary of Contents for AMP 4200

Page 1: ...l 3 Safety Security General Information In addition to this guidance please adhere to your own country specific safety security regulations 3 1 How to use this guide Read these instructions carefully...

Page 2: ...device is not suitable for outdoor operation The ambient temperature should not exceed 30 C 7 Specifications AMP 4200 Power Supply 100 240 V AC 50 60 Hz Output Power 4 x 200 Watt rms Protection Therma...

Page 3: ...U To do this mount the enclosed bracket Note on 19 installation Leave at least 2 U free above the device to prevent overheating With the premounted device feet you can use the AMP 4200 as a standing...

Page 4: ...e sure that the dimensions are correct With 100V technology the total power of the speakers must not exceed 200 W per zone With low resistance connections the total impedance of the loudspeakers must...

Page 5: ...in Password admin This opens the configuration interface Note If you access the amplifier via a network you can also enter http AMP4200 in the start bar If you have changed the user name password in a...

Page 6: ...put matrix DSP equalizer and storage Further to the right you will find the other basic settings of the device the current heat load as well as the device name the IP address of the device and the cur...

Page 7: ...filter and a simple bass tweeter control can be carried out for each output HPF High Pass filter Frequencies above the specified value are let through lower frequencies are filtered out Tone Sound set...

Page 8: ...frequency bands Gain Then set the gain attenuation factor 3 dB is half the output signal Q factor quality between 0 4 to 14 If you select a Q factor of 0 4 a wider frequency range will be processed t...

Page 9: ...nagement You can save up to 20 presets on the device and reactivate them The presets can also be saved and read back on the PC laptop of the service technician Note A RESET reset to factory settings d...

Page 10: ...each channel Note NEVER mix the two technologies in one zone Pay attention to the correct polarity when connecting the speakers When connecting the speakers make sure that the dimensions are correct...

Page 11: ...Saving If Auto is selected as Power Saving the amplifier goes into stand by mode after an extended period approx 20 min without an input signal You can use the trigger function e g if you use a contr...

Page 12: ...st Name Name oft he device IP address Address with which you can call up the device in the browser IPv4 Gateway For connections to the public network Subnet Mask Filter for subnet or host address Prim...

Page 13: ...ds The amplifier is visible in the network You can only expect secure operation if you assign individual passwords When commissioning each device for the first time change the default password first M...

Page 14: ...ve data 2 Combinations with personal details such as the birthday or the name of children should not be used as these can easily be unmasked by others Example Leon1998 or Schatz75 3 Coherent words mea...

Page 15: ...urrent settings 10 3 1 Retrieve the current IP address Press the ADJUST SET button 8 and turn it one step to the left Device Info appears in the display Press the ADJUST SET button 8 again The current...

Page 16: ...k the configuration settings if necessary email us your configuration file Humming Make sure that the inputs on the amplifier are connected Otherwise there is a ground problem due to grounding shieldi...

Page 17: ...astic metal and electronic parts can all be recycled 15 Declaration of Conformity This product supports all CE criteria The certificate can be requested at WHD 16 Name and address of the manufacturer...

Reviews: