background image

WARNING: DO NOT

unscrew the rear section as interference with the internal

electrics will render the pump unfit for use - this is a non-serviceable part of the pump.

NOTE:

Winterizing - Fully drain system

Whale® cannot guarantee warranty if the system is not fully drained for winterizing

For installation or service advice please contact Whale® customer support:

UK Tel: +44 (0)28 9127 0531 

USA Tel: 1 802 367 1091

UK Fax: +44 (0)28 9146 6421

USA Fax: 1 802 367 1095

UK Email: [email protected]  

Email USA: [email protected]

Trade marks - Whale® and Gulper ® are registered trademarks to Munster Simms

Engineering limited (also trading as Whale® Water Systems) 

Whale® Gulper® IC products are protected by the following patent applications: 

P92580GB00

P92043GB00

Failure to 

prime - Motor 

operates, but 

no pump 

discharge

Debris under flap valves 

/ not seated properly

Turn off  electrics and disconnect plumbing 

check valves for blockages and remove 

debris (See section 14) 

Air leak in intake line

Check hose connections are airtight. Open  

pump head and check valves and 

diaphragm (see section 14)

Punctured pump 

diaphragm

Replace the damaged part using service kit 

- Part number AK2050

Restricted intake or 

discharge line

Check all hose connections are airtight, 

free from blockages, and hose has not 

collapsed/kinked.

Pump fails to 

turn off when  

required

Strainer IC bilge strainer,   

not working

Check Strainer IC is operating properly 

(see section 13).

Defective/ debris on 

grey waste float switch

Clear debris/ replace float switch. 

Insufficient voltage to 

the pump

Check power supply to pump.

Override switch activated

Turn off override switch

Low flow

Air leak at pump intake

Check the hose connections are airtight.

Debris inside pump and 

plumbing

Turn off electrics and disconnect plumbing, 

check for blockages and remove (See  

section 14)

Punctured pump 

diaphragm

Replace the damaged part using service   

kit- Part number AK2050

Defective electronic 

control

Replace  pump. If within specified warranty 

period contact Whale (see contact details)

17. WINTERIZING 

18. SERVICE SUPPORT DETAILS

19. PATENTS AND TRADEMARKS

All manuals and user guides at all-guides.com

Summary of Contents for BP2083B

Page 1: ...8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with 2m 6ft cable SI8224B Bulk Strainer...

Page 2: ...rimary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilge Pump INSTALLATION USE...

Page 3: ...p Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strainer IC Horizontal easil...

Page 4: ...ONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent Control Technology At...

Page 5: ...Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid accumulation of water due...

Page 6: ...a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 ii Mounting Instructions Gulper IC G...

Page 7: ...ot over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig 4 NOTE In order to secu...

Page 8: ...t reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor performance and potential m...

Page 9: ...C SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework to connect to the pump S...

Page 10: ...at the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the electrical supply Opti...

Page 11: ...he inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the isolator switch is on and working C...

Page 12: ...intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit Part number AK2050 Rest...