INSTALLATION

The power inverter should be installed in a location that meets the following requirements:
• 

Dry

 – Do not allow water to drip or splash on the inverter.

• 

Cool

 – Ambient air temperature should be between -20°C and 50°C, but the cooler the better.

• 

Safety

 – Do not install batteries in the compartment or other areas near flammable fumes such 

as fuel storage areas or engine compartments.

• 

Ventilated

 – Allow at least one feet of clearance around the Inverter for air flow. Ensure the 

ventilation shafts on the rear and bottom of the unit are not obstructed.

• 

Dust-free

 – Do not install the Inverter in dusty environments here dust, wood particles or  

other filings/shavings are present. The dust can be pulled into the unit when the cooling fan is 
in operation.

• 

Close to batteries 

– Avoid excessive cable lengths but do not install the inverter in the same 

compartment as batteries.

•  Use the recommended wire lengths and sizes (refer to section 4.DC wiring connections).
•  Do not mount the inverter where it is exposed to the gases produced by the battery. These 

gases are very corrosive and prolonged exposure will damage the inverter.

Shock Hazard. Before proceeding further, carefully check that the inverter is NOT connected to 
any batteries, and that all wiring is disconnected from any electrical sources. Do not connect the 
output terminals of the inverter to an incoming AC source.

FUNCTIONAL CHARACTERISTICS

WF-5200-AD Series Pure Sine Wave Inverter

GENERAL INFORMATION

WF-5200 series is new generation power inverter equipped with AC transfer switch. WF-5200 
series is suitable for RV, Marine and Emergency appliances.
Features
•  User-friendly remote control
•  RS-232 & RVC communication
•  Input & output fully isolation
•  UVP & OVP is selectable by remote control (R20D)
•  Input Protection: Reverse Polarity (Automatic) / Battery Under Voltage / Battery Over Voltage / 

Grid Under Voltage / Grid Over Voltage Protection

•  Output Protection: Short Circuit / Overload / Over Temperature Protection
To get the most out of the power inverter, it must be installed and used properly. Please read the 
instructions in this manual before installation and operation of this model.

Summary of Contents for WF-5200 Series

Page 1: ...S MANUAL WF 5200 SERIES PURE SINE WAVE INVERTER WF 5220 ARTERRA DISTRIBUTION 877 294 8997 wfcoelectronics com WARRANTY warranty wfcoelectronics com Fax 574 294 8698 Distributed by Arterra in the U S A and Canada ...

Page 2: ...FCO Electronic IND CO For the conditions of the permission to use this manual for publication contact WFCO Electronic IND CO LTD In all related WFCO product activities Neither WFCO Electronic IND CO LTD nor its distributors or dealers be liable to anyone for indirect incidental or consequential damages under any circumstances Specifications are subject to change without notice Every attempt has be...

Page 3: ...el tanks joints fittings or other connection between components of the fuel system An over current protection at the time of installation shall be provided by others for the AC output circuit Additional breakers suitable for 20 A branch circuit protection shall be provided for the GFCI receptacles PRECAUTIONS WHEN WORKING WITH BATTERIES If battery acid contacts skin or clothing wash immediately wi...

Page 4: ...not mount the inverter where it is exposed to the gases produced by the battery These gases are very corrosive and prolonged exposure will damage the inverter Shock Hazard Before proceeding further carefully check that the inverter is NOT connected to any batteries and that all wiring is disconnected from any electrical sources Do not connect the output terminals of the inverter to an incoming AC ...

Page 5: ...anners Household items vacuum cleaners fans fluorescent and incandescent lights shavers sewing machines Kitchen appliances coffee makers blenders ice markers toasters Industrial equipment metal halide lamp high pressure sodium lamp Home entertainment electronics television VCRs video games stereos musical instruments satellite equipment Vehicle yacht and off grid power systems ...

Page 6: ...4 ELECTRICAL PERFORMANCE WF 5220 Specification ...

Page 7: ...5 DE RATING CURVE ...

Page 8: ...6 MECHANICAL DRAWINGS ...

Page 9: ...Output Please refer to hard wiring installation AC output socket please refer to 4 2 AC INPUT CIRCUIT BREAKER The AC input circuit breaker protects the model from overload When an overload condition exists the circuit breaker stops supplying output AC grid power The breaker will recover automatically CHASSIS GROUND CONNECT THE WIRE 8 AWG TO VEHICLE CHASSIS Operating the inverter without a proper g...

Page 10: ...iring connections RVC BUS portDC LCM port is for remote control connection only Please make sure the connection is correct CAN cable to CAN1 CAN2 port Remote cable to LCM port If CAN cable is connected to LCM port or vice versa the inverter will be damaged ...

Page 11: ...hould be as short as possible less than 32 8 feet 10 meters so that they can handle the signal TERMINAL RESISTOR LCM PORT Connection for LCD remote control panel you can set and display the WF 5200 series operation status ...

Page 12: ... for setting up the inverter charger operation as well as viewing current status or fault messages ON OFF Pushbutton To turn on off UNIT quickly Four Buttons Click buttons allows you to select a menu item or to save a setting once it is displayed on the LCD screen Turning the unit OFF does not mean to disconnect the batteries or AC Power Source Therefore the AC output load is still active Only use...

Page 13: ...nimizes insulation damage such as chafing which can be caused by vibration or constant rubbing when installing this remote in a boat RV or truck INSTALLATION OVERVIEW The remote is required in order to connect the inverter Each inverter must be connected directly to the remote using the supplied RJ11 communication cables The remote must be located close to the inverters within nine meters and acts...

Page 14: ...12 FRONT PANEL ...

Page 15: ...13 R20D MENU MAPS UNI Treadings Setup UNIT LED Indicator ...

Page 16: ...rely Make sure all the DC connections are tight torque to 11 ft lbs 15 Nm Max Loose connections could overheat and result in a potential hazard The installation of a fuse must be on the positive cable Failure to place a fuse on cables running between the inverter and battery may cause damage to the inverter and will void warranty Also only use high quality copper wire and keep the cable length sho...

Page 17: ...on a small spark is a normal phenomenon because the internal capacitors charging Do not be concerned DC INPUT TERMINALS Connect DC input terminals to 12V 24V 48V battery or other power sources represents positive represents negative Reverse polarity connection can blow the internal fuse and may damage the inverter permanently ...

Page 18: ...nection and this function will make external control panel wiring easier GENERAL MODEL Step 1 Remove the four screws of AC wiring compartment and pull it out with care Step 2 Pull the line through the snap bushing of the AC wiring compartment cover then follow below picture operation ...

Page 19: ...17 100VAC 120VAC AC System Connect AC output and AC input wiring to the WF 5200 series terminals Please take the following information as your reference ...

Page 20: ... NEUTRAL CONDUCTOR N OF THE AC OUTPUT AND SAFETY GROUND PE GND GFCI CONNECTOR Recommend GFCI connector HUBBELL INC WIRING DEVICE DIV Type GFRST20W Rated 125V 20A LEVITON MFG CO INC Type GFWR2 Rated 125V 20A COOPER WIRING DEVICES Type SGF20 Rated 125V 20A PASS SEYMOUR INC Type 2097W Type 2097TRWR Rated 125V 20A ...

Page 21: ...is terminal as it will be at an elevated voltage almost half the value the AC output voltage with respect to the metal chassis earth ground and may produce an electrical shock when touched When the unit is transferring power from the AC input source the grounding condition of the N terminal of the AC output will be the same as the condition of the N terminal of the AC input source If the AC input ...

Page 22: ...r products are operational before delivery and the warranty service is offered to the unit which has defect caused under normal use in the judgment of WFCO s technician The warranty is null and void under the following circumstances If the unit has been damaged through abuse misuse negligence such as bumping wetting fault voltage supply air water pollution accidents and natural calamities If the s...

Page 23: ...21 ...

Page 24: ...ARTERRA DISTRIBUTION 877 294 8997 wfcoelectronics com WARRANTY warranty wfcoelectronics com Fax 574 294 8698 Distributed by Arterra in the U S A and Canada Power PROs Technical Support 877 294 8997 ...

Reviews: