If the input from shore power is 105 Vac-130 Vac to the receptacle, 
check the reverse battery protection fuse on the front plate of the 
WF-9800 deckmount converter. Visually inspect the fuses for any 
breaks/opens. If the fuses do not appear to be open, use a tester to 
check for continuity.

 

 

RECEPTACLE
  AC OUTPUT
(Power Center)

DC
OUTPUT

Reverse
Battery 
Protection
Fuses

M

O

D

E

L

W

F

-9

8

X

X

MODEL LABEL

AC INPUT

SHORE POWER
    AC OUTPUT
  (30 A OR 50 A)

SERIAL LABEL

.

If the reverse polarity fuses are blown, it means the RV battery was 
accidentally connected in reverse, either at the battery or at the 
converter. Reconnect properly, then replace the fuse with the same 
type and amp rating as the original “Littelfuse ” Type 257 automotive- 
style fuse.

IMPORTANT: 

These fuses protect the converter from damage in the 

event that the RV battery is accidentally connected in reverse. A reverse 
battery connection, even for a second, is the only reason that these fuses 
will blow

 

  

TM

TM

Converter Operation Modes

All WFCO power converters are automatic three-stage switching 
power supplies. The converter senses which mode it needs to be in by 
checking the RV system voltage.

The three modes/stages of operation include:
Absorption mode/Normal operation

Nominal battery charge and supplies power to appliances

Bulk mode/Charge mode

Fast battery charge and supplies power to appliances

Float mode/Trickle charge

Trickle battery charge during storage

Absorption Mode:

 During this mode, the converter output is in the 

13.6 Vdc range. This is the normal operation mode. This mode 
provides the 12 Vdc and current required by the 12 Vdc RV appliances, 
as well as slow charging the battery.

Bulk Mode: 

When the converter senses that the RV system voltage is 

less than 13.2 Vdc (equivalent to less than 50% of battery charge) the 
converter will automatically go into the “Bulk mode.” In this mode, the 
output voltage of the converter will switch to 14.4 Vdc for a maximum 
of four hours. If the converter cycles between “Absorption and Bulk 
mode,” there could be  a shorted battery cell or other issues.

If the output voltage drops below 13.2 Vdc, the converter automatically 
changes to a “Bulk mode” 14.4 Vdc (unless the converter is in overload 
condition). There are two signs of an overloaded converter: 
Low output voltage, and full converter fold back or shutdown. In both 
cases, the converter will automatically turn ON, once the complete load 
is removed. For low output condition, removing the extra (over the 
current rating) load will be sufficient. If it is impractical to remove all 
the load, resetting the main breaker will have the same effect.

Float Mode: 

If the RV is not being used for approximately 48 hours, 

with a “no load” condition and the shore power is plugged in, the 
converter will automatically go in to the “Float mode.” In this mode, 
the converter is charging the battery with a trickle voltage of 13.2 Vdc. 
When the converter senses a demand (by turning on lights), the 
converter automatically returns to the “Absorption mode” 13.6 Vdc.

 

Ground

FUSE

FUSE

POS

NEG -

+

RED

BLACK

ATC Style

“Littelfuse ” Type 257 fuse

®

Troubleshooting WF-9800 Series Converter

®

Summary of Contents for ULTRA III WF-9800 Series

Page 1: ...For use with WFCO ULTRA III Deckmount Converter WF 9800 Series model number located on the cover of the unit Distributed in the U S A and Canada by CHENG USA INC Sales 574 294 8997 Warranty Service 877 294 8997 Fax 574 294 8698 TM ...

Page 2: ...he owner may store items as this could reduce the clearance requirements obstruct ventilation openings and affect the efficient operation of the converter Do not install close to appliances that are a source of heat or water such as water heaters furnaces and under refrigerators It is not designed for mounting in wet locations It must be protected from direct contact with water FOR CONTINUED PROTE...

Page 3: ...utput Load Curve Model WF 9835 9845 9855 9865 and 9875 13 6 Vdc 13 2 Vdc 0 0 Vdc 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Over the amperage rating load will cause the output to fold back WF 9800 Facts Summary 9835 9845 9855 9865 9875 WF 9800 Series Specifications Model No AC Input Voltage V Current A DC Output Volts V Amps A Height in Width in Length in Weight lbs Fan Cooled Dimensions WF...

Page 4: ...Absorption Mode During this mode the converter output is in the 13 6 Vdc range This is the normal operation mode This mode provides the 12 Vdc and current required by the 12 Vdc RV appliances as well as slow charging the battery Bulk Mode When the converter senses that the RV system voltage is less than 13 2 Vdc equivalent to less than 50 of battery charge the converter will automatically go into ...

Page 5: ... the converter is not functioning properly Contact Cheng USA Inc Tech Support at 1 877 294 8997 WF 9800 Series Troubleshooting CHASSIS EARTH GROUND 0V 2 0 V Distribution Panel Power Center WF 8930 50NP GROUND BAR TM TM GENERAL COMPLIANCE INFORMATION FCC Compliance Class B NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the...

Page 6: ...negligence or accident or any WFCO product installed in a commercial vehicle Any WFCO product whose serial number has been defaced altered or removed Any WFCO product whose installation has not been in accordance with the WFCO written instruction Any consequential damages arising from the loss of use of the product including but not limited to inconvenience loss of service loss of revenue loss or ...

Reviews: