2.3

 

Application Example 1 

The following diagram shows a standalone UltraFlex Mini PC V2 driving 7 screens:  

 

 
 
 

2.4

 

Application Example 2 

The following diagram shows chassis mounted UltraFlex Mini PC V2s each driving 3 screens:  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Figure 1 - Example 1

 

Figure 2 - Example 2

 

Summary of Contents for UltraFlex Mini PC V2

Page 1: ...WEY Technology AG MAN22771_E06 docx 18 04 2018 Dorfstrasse 57 8103 Unterengstringen Schweiz T 41 44 751 89 89 info ch weytec com www weytec com 1 MANUAL FOR ULTRAFLEX MINI PC V2 Part No 22771 ...

Page 2: ...and layouts contained therein They may not be duplicated saved transferred disseminated or made available to third parties neither in whole nor in part without the prior written consent of WEY Technology AG They may only be used for the intended operation of a legally acquired product or program within the business of the purchaser WEY Technology AG Version Date Remarks Initials E01 11 07 2016 Dra...

Page 3: ...duction 8 2 2 Benefits 8 2 3 Application Example 1 9 2 4 Application Example 2 9 2 5 Application Example 3 10 3 Product Overview 11 3 1 Technical Specifications 11 3 2 Operating Conditions 12 3 3 Approval 12 3 4 Available models 13 3 5 Components 14 3 5 1 Front View 14 3 6 Indicator LEDs 15 3 6 1 Front view 15 3 6 2 Chassis 16 3 6 3 Front View 6 slot Standalone Rear View chassis Power Supply 16 3 ...

Page 4: ...A power 18 3 9 Hardware Accessories 19 4 Determining the Configuration 20 4 1 Collecting information 20 4 1 1 Desk 20 4 1 2 User 20 4 1 3 IT Policy 20 5 Operational Guide 21 5 1 Assembly 21 5 2 Installation 21 5 3 Custom UltraFlex image 21 6 Supported Video Resolutions 22 6 1 Onboard Outputs DP1 DP3 22 6 2 Triple External Outputs DP4 DP6 22 6 3 Quad External Outputs DP4 DP7 22 7 Troubleshooting 23...

Page 5: ...rovide good ventilation Use the equipment exclusively for its hereby specified purposes and keep it unplugged during installation and handling 1 1 1 Power supply Ports and Cables WARNING Risk of fire or electric shock Ensure correct voltage 110 230V Use only affiliated AC power adapter Connect equipment to easily accessible grounded main power outlet Replace worn out or damaged cables AC power ada...

Page 6: ... ethereal or volatile gas Avoid environmental hazards such as dust dirt food liquids chemicals temperature extremes vibrations and abrupt changes in humidity or temperature In case of condensation on or within the units allow sufficient time for the moisture to evaporate Do not use artificial means to speed up the drying process Before using the equipment again verify that all connected units are ...

Page 7: ...action or a sequence of actions to be taken 1 3 Warranty Limitations The warranty term for the WEY Products is 12 months as per delivery date The manufacturer does not assume any general liability or liability to pay any compensation or damages if any part of the manufacturer s instructions are violated Warranty and liability shall not exceed the minimal extent as defined by applicable law and Wey...

Page 8: ...he UltraFlex Mini PC V2 is mounted in a standalone with one or two 12V power supplies or 19 chassis with single or dual PSUs UltraFlex Mini PC V2 is configured to run Windows 7 Pro Windows 8 1 Pro and Windows 10 Pro 2 2 Benefits UltraFlex Mini PC V2 can support up to seven screens Extremely compact design with redundant power supply option Fast boot and performance using SSD Dual Gigabit Ethernet ...

Page 9: ...51 89 89 info ch weytec com www weytec com 9 2 3 Application Example 1 The following diagram shows a standalone UltraFlex Mini PC V2 driving 7 screens 2 4 Application Example 2 The following diagram shows chassis mounted UltraFlex Mini PC V2s each driving 3 screens Figure 1 Example 1 Figure 2 Example 2 ...

Page 10: ...18 Dorfstrasse 57 8103 Unterengstringen Schweiz T 41 44 751 89 89 info ch weytec com www weytec com 10 2 5 Application Example 3 The following diagram shows chassis mounted UltraFlex Mini PC V2s driving a combination of screens Figure 3 Example 3 ...

Page 11: ...2EQ HD Graphics 530 3x 4096x2304 60Hz Intel Core i7 6822EQ HD Graphics 530 3x 4096x2304 60Hz Audio Stereo 48KHz 16 Bit 1Vrms 20Hz 20KHz Data 2x USB 2 0 HighSpeed 2x USB 3 0 SuperSpeed and 2x Gigabit Ethernet MTBF 80KHrs Interfaces Connectors USB 2 x USB 3 0 Type A SuperSpeed 2 x USB 2 0 Type A HighSpeed SATA 2 x SATA 6Gb s SATA III max 5Watt per port mSATA 1 x mSATA 6Gb s Ethernet 2 x Gigabit RJ45...

Page 12: ... 89 89 info ch weytec com www weytec com 12 3 2 Operating Conditions Operating temperature 8 40 C Storage temperature 0 60 C Operating location Indoor use Relative humidity 45 85 non condensing Operating altitude Max 2000 m 3 3 Approval The UltraFlex Mini PC V2 is Class B FCC and CE conform and approved ...

Page 13: ... HD Graphics 400 2x 2560x1600 60Hz Intel HD Graphics 530 3x 4096x2304 60Hz Intel HD Graphics 530 3x 4096x2304 60Hz NV Quadro P400 3x 4096x2160 60Hz 1x 5120x2880 60Hz Intel HD Graphics 530 3x 4096x2304 60Hz NV Quadro P600 4x 4096x2160 60Hz 4x 5120x2880 60Hz Intel HD Graphics 530 3x 4096x2304 60Hz RAID Slot Enclosure Power consumption 16 W max Power consumption 35 W max Power consumption 60 W max Po...

Page 14: ...es show the UltraFlex Mini PC V2 including connectors and LEDs 3 5 1 Front View 1 Power switch and HDD SSD activity LED 2 3 x Mini DP 3 4 x Mini DP optional alternatives are none or 2 x DP 4 2 x USB 3 0 SuperSpeed blue 2x USB 2 0 HighSpeed black 5 Audio in blue Microphone in pink and Audio out green 6 2 x Gigabit Ethernet connecters with Link and Activity LEDs Figure 4 Components ...

Page 15: ...indicate the following states 3 6 1 Front view HDD HDD SSD activity Blinking Ethernet Left Gigabit Ethernet link established Ethernet Right Link Activity Data send receive On when link established and Steady Blinking when data sent received Blinking Gigabit connection steady yellow LED and steady or blinking green LED 10 100M connection steady or blinking green LED only Figure 5 UltraFlex V2 front...

Page 16: ... ch weytec com www weytec com 16 3 6 2 Chassis 1 Power Supply 1 2 Power Supply 2 Power Supply Power Supply OK Power Supply Error Blinking 3 6 3 Front View 6 slot Standalone Rear View chassis Power Supply Power Supply Power Supply OK Power Supply Error Blinking Figure 6 Chassis front Figure 7 PSU Indicator LEDs 2 1 ...

Page 17: ...the UltraFlex is configured with an optional graphics card either 3 x Mini DP or 4 x Mini DP connectors are available to connect additional screens These connectors can use active or passive adaptors for DVI HDMI screens 3 7 5 2 x USB 3 0 SuperSpeed Each USB 3 0 SuperSpeed connector supports USB 3 0 Superspeed and is backward compatible with USB 2 and USB 1 devices 3 7 6 2 x USB 2 0 HighSpeed Each...

Page 18: ...A Data connectors Two Standard SATA Data connectors for use with additional SSD s Used when UltraFlex V2 is supplied in a RAID configuration 3 8 2 Audio in selection The Audio in can be set to Line in when both jumpers fitted to left as above or Mic in when both jumpers fitted to the right 3 8 3 SATA power Non standard SATA power connection supplying 5v and 3 3v for mSATA module using an adaptor o...

Page 19: ...luding fan 12V PSU and 2 external 12V power socket 23641_6 WEY Box 6 slot 3U including fan 12V PSU and 2 external 12V power socket 23129DP180W Chassis 19 3U DVI VSS2 Desk Rack 16 Slots Address Bus incl 2xPSU 12V 23537_180W Jumpers out 4xMiniDin 3pin Power 20259S Mini DisplayPort to DVI Single Link Active Converter 20843L1 Cable Mini DisplayPort to DVI Active Adapter Converter Cable mDP to DVI 2560...

Page 20: ...Pro x64 or no OS Deployment position workload screens position local resilience requirement and company IT policy will determine the required options 4 1 Collecting information To determine the required UltraFlex options there are three key areas that need to be investigated Desk User and IT Policy 4 1 1 Desk The following will help determine Ultraflex options Space in desk for Ultraflex Number of...

Page 21: ...nmental Conditions described in Chapter 1 Make sure you slide the print boards into the rack without touching soldering points or components Do not move the equipment once installed Provide sufficient ventilation 5 2 Installation Mount the UltraFlex Mini PC V2 into the appropriate standalone box or 19 chassis Connect keyboard and mouse Connect the screens using MiniDP to DP cables or via WEY appro...

Page 22: ... resolutions from 800 x 600 60 Hz to 4096 x 2304 60Hz o 3x 4096x2304 60Hz DP Note Specification of the video output are differ if an older Intel i7 3517UE CPU is installed in the UltraFlex Mini PC V2 The specification of the video output for this CPU s are described in the manual UltraFlex Mini PC Part No 22751 6 2 Triple External Outputs DP4 DP6 The external board UltraFlex video outputs DP4 DP6 ...

Page 23: ...em or the actions fail to resolve the problem please contact your local WEY Customer Support Problem Action No power Ensure that all power supply units are firmly plugged to the mains and check the voltage with a voltmeter No Video Verify that all video connection cables are intact and firmly connected No Ethernet Link Activity Ensure that the RJ45 connectors and cables are secure and not damaged ...

Page 24: ... weytec com adressen Singapore WEY Technology Singapore Pte Ltd www weytec com addresses France WEY Technology Sarl www weytec com adressen Australia WEY Technology Asia Pacific Pty Ltd www weytec com addresses Italy WEY Technology S r l www weytec com adressen Taiwan WEY Technology Singapore Pte Ltd Taiwan Branch www weytec com addresses Austria WEY Technology Austria www weytec com adressen Hong...