WD-PRM6 & WD-PRM7
Rev. 5.0 (201902)
Installation instructions
12
3.5.1
Electrical connection
Information about electrical connections is available on the machine’s wiring dia-
gram which is provided on delivery. Store the diagrams in the plastic pocket, lo-
cated in the electrical cabinet, even after installation.
•
The machine is designed for quick electrical installation.
•
The machine must be connected to a lockable main switch. This should be
placed on a wall, well-protected from water and from the steam which es-
capes when the machine is opened. The machine is supplied with the elec-
trical cable connected (2).
After completing the installation, switch on the main switch and all circuit break-
ers.
3.5.2
Water connection, regardless of any options
•
The dishwasher fills with water (3) via the dishwasher that the WD-PRM6/
7 is connected to.
•
If the machine has a water-powered automatic hood, the water is connect-
ed to (5).
•
The required water flow and pressure can be found in the TECHNICAL
SPECIFICATIONS. If the water pressure is too low, a booster pump must
be fitted.
3.5.3
Ventilation
The machine’s heat load for the room is stipulated in TECHNICAL SPECIFICA-
TIONS.
3.5.4
Drain/waste pipe
The waste water system connected to (4) should consist of a 50 mm metal pipe
that will withstand mechanical impacts. The drain must run to a floor drain, where
its opening must be above the water level.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.
Connecting the dishwasher
The length of level pipe that is firmly fitted on WD-PRM6/7 varies depending on
which dishwasher it should be connected with.
WD-6x and WD-7x:
WD400031.01
WD-12x:
WD400031.03
Setting the pressure switch:
Upper level:
Lower level:
WD-PRM6 / 7
265 mm
155 mm
WD-12
350 mm
270 mm
Summary of Contents for WD-PRM6