WD-ACS 47D
Rev. 1.0 (202003)
Installation instructions
11
3.5
Installation
3.5.1
Preparing for the installation
Check that there is sufficient room for the machine at the installation location.
•
Check that correct connections are available for water, electricity, drainage
and possibly steam at the installation location. See TECHNICAL SPECIFI-
CATIONS.
•
Check that the overheating protection device is reset.
3.5.2
Positioning the machine
Check the following points before the machine is placed in position:
•
Check that the fuse for the machine at the site is off, blocked and that out-
going electrical circuits from the machine are non-live.
•
Remove the protective plastic on the sides which are to be stood against a
wall.
•
The distance between the wall and machine should be at least 100 mm.
Place the machine in position and check that it, and any accessories, are horizon-
tally level. Adjust the height with the legs.
Check with a spirit level that is standing level. Place the spirit level on the join be-
tween the machine tank and the upper part. Once the machine has been filled
with water, do another check to make sure the machine is standing level. Close
the doors and check that the tops of the doors are in a straight line. Adjust the
machine using the legs.
The machine must be evenly balanced on three sides:
•
On the cover edge of the front side (a) (tank body).
•
On the cover of the infeed (b).
•
On the cover of the outfeed (c).
b
a
a
a
a
a
c
ACS-47D_07_R1
Summary of Contents for WD-ACS 47D