WD-59CT & WD-66CT
Rev. 2.0 (20110124)
Instructions for use
36
(51) OVERLOAD FEEDING AC-
TIVATED - REMOVE OBJECT -
RESTART FEEDING
An object has stopped the belt.
Remove the item. Start the feed by pressing but-
ton (5).
(85) OVERLOAD FEEDING AC-
TIVATED - PRESS RESET
---
Reset the alarm by pressing button (9).
(52) FEEDER LIMIT SWITCH
ACTIVATED - REMOVE OB-
JECT FROM THE FEEDER LIM-
IT
An object has activated the pho-
tocell (15).
Remove the object. The conveyor will start auto-
matically.
(53) ALARM TRAY EXCHANG-
ER - CHECK TRAY EXCHANG-
ER
The tray exchanger has
stopped.
Start the tray exchanger.
(54) TRAY DISPENSER OUT
OF POSITION - CHECK TRAY
DISPENSER
The tray dispenser is in the
wrong position or there is no tray
dispenser in place.
Adjust the dispenser if it is in the wrong position
or connect an empty dispenser to the machine
or tray exchanger.
(55) TRAY DISPENSER FULL -
CHECK TRAY DISPENSER
---
Change the dispenser.
(56) OVERLOAD CUTLERY
TRACK ACTIVATED - CHECK
AND RESTART FEEDING
The cutlery has jammed and has
activated the switch inside the
door (14).
Open the door and remove the cutlery. Start the
feed by pressing button (5).
(57) END LIMIT CUTLERY
TRACK ACTIVATED - CHECK
CUTLERY TRACK
The door (14) is not closed.
Close the door. The conveyor will start automat-
ically.
(71) WASHING DETERGENT
ALARM ACTIVE - CHECK DE-
TERGENT DEVICE
The detergent has run out.
Check and fill with new detergent.
(77) FINAL RINSE ERROR -
SENSOR ERROR FLOW ME-
TER BV02
---
Reset the alarm by pressing button (9).
(76) FINAL RINSE ERROR - NO
FLOW IN THE MACHINE
The water supply is shut off.
Check that the stopcocks on the incoming water
supply are open. Reset the alarm by pressing
button (9).
(75) FINAL RINSE ERROR -
LOW FLOW IN THE MACHINE
The rinse nozzles (19) for the fi-
nal rinse are blocked.
Clean the nozzles. Reset the alarm by pressing
button (9).
(83) TIME FOR MAINTENANCE
- CONTACT YOUR MAINTE-
NANCE SUPPLIER
---
Contact service personnel. Reset the alarm by
pressing button (9).
Alarm texts
Alarm text
Cause
Action