background image

WebDT Mobile Tablet Barcode Scanner Operation Guide

Mobile

s

 Tablet

 

Magnetic Stripe Reader

MSR 1/2

Installation

The Magnetic Stripe Reader (MSR) is preinstalled as an option for  DT 39

2

To Connect Magnetic Stripe Reader Module

 

To connect the Magnetic Stripe Reader, you can use the 

DT Keyboard Wedge

. Tap on the         

icon in the task bar, a menu is displayed as shown in the picture below. Choose 

Connect MSR

.

To Configure MSR

 

For a magnetic stripe card, the raw data in each data track may contain start and end sentinel 
characters. To remove those characters, you can select the 

Configure MSR

 command to parse 

input raw data and filter out the start and end sentinel characters on each track.

Click 

1. 

Config MSR

 in the 

DT Keyboard Wedge

 menu, 

and the 

MSR Parse Format Setting

 window will be 

displayed.
Choose 

2. 

Enable

 in the Parse Data section.

Choose data you want to parse at the start or end of each 

track. 

For Example:
Check Track 1

In Start Sentinel Character, select %

• 

In End Sentinel Character, select ?

• 

Click 

3. 

OK

 to complete the settings

DT 39

OPERATION GUIDE    

MSR connected

MSR

Summary of Contents for DT 392

Page 1: ...n The Barcode Scanner is preinstalled as an option for DT 392 DT 392 OPERATION GUIDE Scanner 1 2 Barcode Scanner Trigger Button Scanner Configuration To Add Remove Symbologies follow the procedures below 1 Click Start All Programs DT Research Button Manager ScannerConfig 2 Select COM3 and click Connect button 3 Add Symbology with button and Remove Symbology with button 4 Select the Beep after scan...

Page 2: ...ts 1 Flow Control None Note Please refer to Hyper Terminal Settings to confirm or change the port parameters SPECIFICATIONS Scanning Performance Scan rate 2D mode 56 images s auto adaptive Linear 1D emulation mode 200 scans s auto adaptive Scan angle 38 9 Horizontal 25 4 Vertical Optical resolution 752 H x 480 V pixels 256 gray levels Print contrast down to 25 Versions Standard range and high dens...

Page 3: ...o take a picture Select a captured picture on right column click Get Picture to export the picture to Paint or click Delete to delete the picture 4 4 4 Button Management To assign Camera Trigger button follow the procedures below 1 Start Button Manager by clicking on in the system tray 2 Selectanavailableunusedbuttonmarkedwiththeicon 3 Click on to go to the second screen of Button Manager 4 Click ...

Page 4: ...x 1536 Auto Focus Yes Automatic Image Control Automatic exposure control Automatic white balance control Focusing Type Auto focus Focus Distance Focal on 60cm Note Specifications are subject to change without notice Camera 2 2 WETIF Industrie EDV Telefon DE 49 8142 448976 0 Senserstraße 3 Telefon AT 43 664 28 68 223 D 82140 Olching info wetif com www wetif com ...

Page 5: ...tripe card the raw data in each data track may contain start and end sentinel characters To remove those characters you can select the Configure MSR command to parse input raw data and filter out the start and end sentinel characters on each track Click 1 Config MSR in the DT Keyboard Wedge menu and the MSR Parse Format Setting window will be displayed Choose 2 Enable in the Parse Data section Cho...

Page 6: ...yper Terminal Settings to confirm or change the port parameters SPECIFICATIONS Reference Standards ANSI ISO Standards 7810 7811 1 6 7812 7813 JIS X6301 X6302 AAMVA Recording Method Two frequency coherent phase F2F Decoding Method ISO Track1 IATA Track2 ABA Track3 THRIFT Card Swiping Direction Bi directional Card Swiping Speed Card speed through the unit may vary from 3ips to 100ips 7cm s to 250cm ...

Page 7: ...hown in the picture below Select Connect RFID To Test RFID Reader Module Click 1 Start All Programs Accessories NotePad to run the Notepad Place the ISO card within a distance of the RFID tag see 2 reading range of specification The output will appear in the Notepad screen Verify the captured data 3 SPECIFICATIONS Frequency 13 56MHz 7 KHz Module Mode FSK Reading Range Within 30mm HF RFID Reader IS...

Page 8: ...name in Connection Description window 3 Choose the connection port please refer to the parameters table of each module then click OK 4 Change the port Properties please refer to the parameters table of each module then click Apply to complete the settings 5 If the settings are all correct HyperTerminal will be connected to the module Scan a barcode or swipe a card the captured data will display in...

Reviews: