TESTING APPLIANCE OPERATION

After installation, test the appliance and ensure that it 

operates correctly before handing it over to the customer. 

The following procedure is recommended:

1.   Turn on the gas and electricity supply and attempt 

ignition on all burners, both separately and in 

combination. (For correct procedure, refer to page 4). 

Note that additional time needs to be allowed for the 

initial lighting as air has to be purged from the pipes.

2.   Observe the flame appearance on each burner. 

(Figure 12) If it is much larger or much smaller than 

expected, the injector size and supply pressure 

require checking. Where a flame is unsatisfactory, 

refer to the Troubleshooting Guide (Page 6) to 

correct the fault. If the Troubleshooting Guide does 

not solve the problem, call the Service Centre. 

Flame size adjusted to maximum

Flame size adjusted to minimum

Figure 12

3.   Once all the previous tests are satisfactory, check 

the turndown (minimum or low) setting on each 

burner, as this may need adjustment. Valves have a 

by pass controlling screw, which may be accessed 

by removing the knob. This screw will be located 

on a particular area of the valve. (Refer Figure 13). 

Normally, this will have been correctly set at the 

factory for use on NG (Natural Gas) and should not 

require adjustment.

 

 If the appliance has been converted to LPG, then the 

bypass screw will have to be screwed in until a small, 

stable flame results. 

Figure 13

Bypass screw

 

 Please ensure the supply pressure has been checked 

PRIOR to any adjustment.

4.   If the appliance cannot be adjusted to perform safely, 

inform the customer of the problem and affix an 

appropriate warning notice to the appliance. If the 

fault appears to be dangerous the appliance should 

be disconnected. If a minor fault exists, the customer 

may wish to use the appliance while awaiting service.

 

 If a fault cannot be fixed, please call the  

Service Centre.

5.   The customer should be advised that, in the event  

of a fault, the local Service Organisation or the retailer 

from whom the appliance was purchased should  

be contacted.

TESTING APPLIANCE OPERATION

6.   When satisfied that the unit is operating correctly, 

turn off and instruct the customer on correct 

operation as outlined in this booklet. Ask the 

customer to operate the controls to ensure that the 

correct procedure is understood.

WARNING

WARNING

Servicing must only be carried out by an authorised 

service person.

Injector sizes required for various gas types are shown 

in the Technical Data Table (page 11). The appliance inlet 

pressure for each gas type is also shown.

For model identification after installation, an additional 

data plate sticker has been provided. This sticker is to  

be stuck onto adjacent cabinetry.

17

NOTES

Summary of Contents for WHG952SB

Page 1: ...USER MANUAL GAS COOKTOPS WHG644SA WHG646SA WHG756SA WHG952SB WHG956SA ...

Page 2: ...ility ensure pots and pans are centrally located on the trivets Handles should be turned away from the front of the bench to avoid accidents Do not modify this appliance Figure 1 1 Burner 2 Flame safeguard sensor 3 Injector 4 Ignition spark plug 1 2 3 4 IMPORTANT SAFETY INSTRUCTIONS Dear customer Congratulations and thank you for choosing our cooktop We are sure you will find your new cooktop a pl...

Page 3: ...G CAUTION DO NOT place burners in a dishwasher Controls Each burner is controlled by a control knob The markings on the control panel indicate which burner the knob controls and the settings for that burner See Figure 2 NOTE Gas controls turn anticlockwise from Off and have limited movement Figure 2 Lighting burners Electronic Ignition These cooktops are fitted with mains powered electronic igniti...

Page 4: ...ensor tip Low heat slow cooking Incorrect cooking pot or pan being used Refer to Figure 3 page 5 Benchtop or knobs overheating Incorrect cooking pot or pan used Check Figure 3 for correct pot or pan to be used Pot or pan not located on burner properly Ensure pot or pan is centrally located on burner Cooktop stainless steel discoloured Pot or pan being used is too large Ensure pot sizes used are as...

Page 5: ...h 49 6 49 6 49 6 Height is distance from the top of the kitchen bench to the bottom of the cooktop INSTALLATION INSTRUCTIONS MODEL CODE DIMENSION MM GAS SUPPLY LOCATION A B C D LEFT OR RIGHT WHG644SA 143 560 490 145 Left WHG646SA 143 560 490 145 Left WHG756SA 146 730 490 145 Left WHG952SB 121 880 490 145 Left WHG956SA 121 880 490 145 Left This appliance must be installed by an authorised person an...

Page 6: ...barrier shield from Electrolux spare parts P No ACC 072 which can be fitted directly to the underside of the product This shield protects the user from accidently touching certain areas of the product Barrier protection is not necessary if the product is installed above an underbench oven or similar appliance and or if the cupboard construction is such that the underside of the cooktop is not acce...

Page 7: ...the checks whilst measuring both the inlet and outlet pressure to determine if the inlet pressure is in the range 1 13 5kPa Regulator An appliance regulator is provided The regulator must be positioned so that the pressure test nipple is accessible when the appliance is installed Connect the gas supply to the B S P internal thread inlet of the regulator Refer to bench cutout Figure 4 for connectio...

Page 8: ...pacity may be present in the gas supply line If this is suspected then it may be necessary to repeat the checks whilst measuring both the inlet and outlet pressure to determine if the inlet pressure is in the range 2 75 7 00kPa Check that the insert has been fitted correctly Check that the turret screw is fully screwed down Check that the regulator has been fitted to the gas supply line in the cor...

Page 9: ...should not require adjustment If the appliance has been converted to LPG then the bypass screw will have to be screwed in until a small stable flame results Figure 13 Bypass screw Please ensure the supply pressure has been checked PRIOR to any adjustment 4 If the appliance cannot be adjusted to perform safely inform the customer of the problem and affix an appropriate warning notice to the applian...

Page 10: ...torm damage or incorrect power supply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii failure to comply with any additional instructions supplied with the Appliance b the Appliance is modified without authority from Electrolux in writing c the Appliance s serial number or warranty seal has been removed or defaced d the Ap...

Page 11: ...iler phone or email our customer care team or visit our website TOP SERVICE Top Service encompasses the after sales service provided by The Electrolux Group to consumers including delivery home service and spare parts Westinghouse We are part of the Electrolux family Share more of our thinking at www electrolux com and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used under lic...

Reviews: