POWER MANAGEMENT

To prolong the life of the generator and attached devices, 

use care when adding electrical loads to the generator. 

There should be nothing connected to the generator 

outlets before starting the engine. The correct and safe 

way to manage generator power is to sequentially add 

loads as follows:

1. 

With nothing connected to the generator, start the 

engine as described in this manual.

2. 

Plug in and turn on the first load, preferably the largest 

load you have.

3. 

Permit the generator output to stabilize (engine runs 

smoothly and attached device operates properly).

4. 

Plug in and turn on the next load.

5. 

Again, permit the generator to stabilize.

6. 

Repeat steps 4 and 5 for each additional load.

Wattage Reference

Tool or Appliance

Estimated 

Running 

Watts*

Estimated 

Starting 

Watts*

Incandescent Lights  

(4 Quantity x 75 Watts)

300

0

TV (Tube Type)

300

0

Sump Pump (1/3 hp)

800

1300

Refrigerator or Freezer

700

2200

Well Pump (1/3 hp)

1000

2000

Furnace (1/2 hp)

800

2350

Radio

200

0

Drill (3/8”, 4 amps)

440

600

Circular Saw 

(Heavy Duty, 7-1/4”)

1400

2300

Miter Saw (10”)

1800

1800

Table Saw (10”)

2000

2000

*Wattages listed are approximate. Verify actual wattage.

EXTENSION CORDS

Asphyxiation hazard. Extension cords running directly 

into the home increase the risk of carbon monoxide 

poisoning through any openings. If an extension cord 

running directly into your home is used to power indoor 

items, there is a risk of carbon monoxide poisoning to 

people inside the home. Always use battery-powered 

carbon monoxide detector (s) that meet current UL 2034 

safety standards when running the generator. Regularly 

check the detector (s) battery.

Asphyxiation hazard. When operating the generator with 

extension cords, make sure the generator is located in 

an open, outdoor area, far away from occupied spaces 

with exhaust pointed away.

Fire and electrocution hazard. Never use worn or 

damaged extension cords. Damaged or overloaded 

extension cords could overheat, arc, and burn resulting 

in death or serious injury. 

Before connecting an AC appliance or power cord to the 

generator:

•  Use grounded 3-prong extension cords, tools, and 

appliances, or double-insulated tools and appliances. 

•  Make sure the tool or appliance is in good working 

order. Faulty appliances or power cords can create a 

potential for electric shock. 

•  Make sure the electrical rating of the tool or appliance 

does not exceed the rated power of the generator or the 

receptacle being used. 

Summary of Contents for WGen9500

Page 1: ...MANUAL WGen9500 Portable Generator Gasoline 9500 Running Watts 12500 Peak Watts DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944...

Page 2: ...tenance on this product Failure to follow the instructions and safety precautions in this manual can result in serious injury or death SAVE THESE INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION DISCLAIMER...

Page 3: ...xposed to temperatures outside of this range during storage it should be brought back within this range before operation This product must always be operated outdoors in a well ventilated area and far...

Page 4: ...a hazardous situation which if not avoided could result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situ...

Page 5: ...properly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws a...

Page 6: ...erflow when filling Shut down the engine and allow it to cool for two minutes before adding gasoline or oil to the generator Never remove the fuel cap when the generator is running Shut off the engine...

Page 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY SAFETY LABELS AND DECALS...

Page 8: ...8 Westinghouse Outdoor Power Equipment LLC FEATURES GENERATOR COMPONENTS...

Page 9: ...imum of 20 Amps 7 120 240 Volt AC 30 Amp NEMA 14 30R Twist Lock Receptacle Receptacle can supply a maximum of 30 Amps 8 120 240 Volt AC 50 Amp NEMA 14 50R Receptacle Receptacle can supply a maximum of...

Page 10: ...lug socket wrench Oil Funnel Assembly wrench Wheel and mounting foot components Mounting foot 2 Flange bolt M8 4 Wheel 2 Shaft pin 2 Washer 2 Cotter pin 2 If any parts are missing contact our service...

Page 11: ...tank Fill only to the red fill ring located in the in tank fuel screen filter Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard Fire and explosion hazard Never refuel...

Page 12: ...nly to the red maximum fill ring on the fuel screen filter visible in the filler neck 5 Install the fuel cap NOTICE Fuel can damage paint and plastic Use caution when filling the fuel tank Damage caus...

Page 13: ...next to walls or buildings or in any other location that will not allow for adequate cooling of the generator and or the muffler DO NOT contain generators during operation Asphyxiation hazard Place t...

Page 14: ...recoil handle or control panel If your unit was shipped without a key fob contact Westinghouse customer service The generator can be started remotely from up to 99 feet 30 meter using the remote start...

Page 15: ...two seconds c Recoil Start Manually close the choke if the engine is cold Firmly grasp and pull the recoil handle slowly until you feel increased resistance then pull rapidly Cold start Close the cho...

Page 16: ...idered Appliance and power tool manufacturers usually list rating information near the model or serial number To determine power requirements 1 Select the items you will power at the same time 2 Total...

Page 17: ...2000 2000 Wattages listed are approximate Verify actual wattage EXTENSION CORDS Asphyxiation hazard Extension cords running directly into the home increase the risk of carbon monoxide poisoning throu...

Page 18: ...tie down straps Do not attempt to lift or secure the generator by holding onto any of its other components Keep the unit level during transport to minimize the possibility of fuel leakage or if possi...

Page 19: ...866 Battery 14 AH 511012 Spark plug 97108 AIR FILTER MAINTENANCE Fire hazard Never use gasoline or other flammable solvents to clean the air filter Use only household detergent soap to clean the air f...

Page 20: ...clean 4 Insert the dipstick into the oil filler neck without screwing it in Remove the dipstick and verify that the oil level is within safe operating range between the low L and high H marks on the d...

Page 21: ...ectrodes are pitted burned or the insulator is cracked Only use a recommended replacement plug 6 Measure the spark plug electrode gap with a wire type feeler gauge If necessary correct the gap by care...

Page 22: ...d down plate and tighten the bolt 7 Connect the quick connect plug NOTICE Dispose of the used battery properly according to the guidelines established by your local or state government STORAGE Proper...

Page 23: ...engine oil into the cylinder and pull the recoil handle until resistance is felt At this position the piston is coming up on its compression stroke and both valves are closed Storing the engine in th...

Page 24: ...enance section Engine starts then shuts down Out of fuel Refuel Incorrect engine oil level Check engine oil level Dirty air filter Clean the air filter Contaminated fuel Drain the fuel tank Refuel wit...

Page 25: ...Westinghouse Outdoor Power Equipment LLC 25 EXPLODED VIEW EXPLODED VIEW A...

Page 26: ...R ASSEMBLY 8 9 262101 ROCKING ARM 8 10 261806 TOP CAP 8 11 91016 AIR INLET STUD STUD BOLT 8 12 91007 AIR EXHAUST STUD STUD BOLT NO PART DESCRIPTION 8 13 94206 SPRING WASHER 8 14 90011 NUT M8 8 15 9608...

Page 27: ...Westinghouse Outdoor Power Equipment LLC 27 EXPLODED VIEW EXPLODED VIEW B...

Page 28: ...ITCH 7 5 94403 FUEL LINE CLAMP 8 60030031 MUFFLER ASSEMBLY 8 1 520305 MUFFLER BRACKET 8 2 91343 BOLT M8X16 8 3 96002 MUFFLER CONNECTING PIPE GASKET 8 4 94206 SPRING WASHER NO PART DESCRIPTION 8 5 7059...

Page 29: ...Westinghouse Outdoor Power Equipment LLC 29 SCHEMATICS SCHEMATICS...

Reviews: