background image

LPG CONVERSION DONG YANG – IMPORTANT  

(MODELS WFE512, WFE614, WFE612 AND WFE616 ONLY)

This appliance is fitted with Natural Gas burner injectors.

Please follow the procedure below if a conversion to suit 

UNIVERSAL LPG is required.

The conversion kit contains 5 injectors and 1 LPG sticker.

1.   Remove the hotplate burners to access the hotplate 

injectors. Replace the factory fitted NG injectors with 

the appropriate injectors, as supplied.

2.   Unscrew the hex nut from the regulator. The hex  

nut, brass washer and nylon insert will disengage  

as an assembly.

3.   Unclip the nylon insert from the nut assembly by 

rotating the insert 1/4 turn, and pulling it free.

4.  Turn over the insert, and clip back into position.

5.   Refit the hex nut assembly to the regulator ensuring 

that it is fully screwed down. The regulator is now set 

for connection to LPG.

6.   Turn on the gas supply and at each new connection 

check for leaks using soapy water: each hotplate 

valve should be turned on, one at a time, and the 

injector hole blocked off for several seconds.

7.   The operation of the regulator can be confirmed by 

connecting a manometer to the pressure test point 

located on the side of the regulator body adjacent 

to the outlet. With the appliance operating check the 

outlet pressure:

 

• 

 When all burners of the appliance are operating  

at maximum,

 

• 

 When the smallest burner of the appliance is 

operating at minimum.

 

 Under these conditions the outlet pressure should not  

vary from the nominal outlet pressure of 2.60kPa by 

more than ±0.52kPa.

8.   If the regulator appears to not be performing 

satisfactorily then check the following points:

 

• 

 If the outlet pressure is consistently too low then  

the inlet pressure may be too low and 

adjustment of an upstream regulator may be 

needed, or an upstream regulator or valve with 

insufficient flow capacity may be present in 

the gas supply line. If this is suspected then it 

may be necessary to repeat the checks whilst 

measuring both the inlet and outlet pressure to 

determine if the inlet pressure is in the range  

2.75 – 7.00kPa.

 

• 

 Check that the insert has been fitted correctly. 

 

• 

Check that the turret screw is fully screwed down.

 

• 

 Check that the regulator has been fitted to  

the gas supply line in the correct orientation, 

the arrow on the base of the body indicates the 

direction of gas flow.

 

 Once these checks have been completed, if the 

regulator still fails to perform in a satisfactory manner 

it should be replaced.

9.   One by one, turn the knobs to minimum and screw 

in the bypass screw (accessible when the knob is 

removed) until a small stable flame results. Turn the 

knob to maximum and then back to minimum to 

ensure that the correct minimum flame is maintained.

10.   Attach the LPG sticker to the cooker, near the gas 

supply inlet. Cover the Natural Gas label that is 

factory fitted.

Hex nut assembly,  

fully screwed down

Hex nut assembly,  

removed from 

regulator and insert 

disassembled

Insert oriented for 

Natural Gas operation

Insert oriented for 

LPG operation

LPG CONVERSION CHANT – IMPORTANT

  

(MODELS WFE512, WFE614 AND WFE612 AND WFE616 ONLY)

This appliance is supplied set up for Natural Gas usage. 

A conversion kit is included with the product for Universal 

LPG usage. The conversion kit contains 5 injectors and 1 LPG 

sticker.

Please follow the procedure below if a conversion to suit 

UNIVERSAL LPG is required:

1. 

 Remove the hotplate trivets, burner caps and burner 

crowns to access the hotplate injectors. Replace the 

factory fitted injectors with the appropriate injectors, as 

supplied. Refer to injector orifice table for injector sizes. 

The injector size is stamped on the side of the injector.

2.   Unscrew the top hat nut from the regulator. The top hat 

nut and control pressure spring assembly will disengage 

as an assembly.

3.   Unscrew the threaded pin from top hat.

4.   Upturn threaded pin, so spring is free and screw pin 

back into the top hat until firm.

5.   Refit the top hat nut assembly to the regulator ensuring 

that it is fully screwed down. The regulator is now set 

for connection to LPG.

6.   Turn on the gas supply and at each new connection 

check for leaks using soapy water. Each hotplate valve 

should be turned on, one at a time, and the injector hole 

blanked off for several seconds.

7.   The operation of the regulator can be confirmed by 

connecting a manometer to the pressure test point 

located on the side of the regulator body adjacent to 

the outlet.

With the appliance operating check the outlet pressure:

 

•   

When all burners of the appliance are operating  

 

at maximum,

 

•   

 When the smallest burner of the appliance is    

operating at minimum.

 

 Under these conditions the outlet pressure should not 

vary from the nominal outlet pressure of 2.60kPa by 

more than ±0.52kPa.

8.   If the regulator appears to not be performing 

satisfactorily then check the following points:

 

•  

 If the outlet pressure is consistently too low then 

the inlet pressure may be too low and adjustment 

of an upstream regulator may be needed, or an 

upstream regulator or valve with insufficient flow 

capacity may be present in the gas supply line. 

If this is suspected then it may be necessary to 

repeat the checks whilst measuring both the 

inlet and outlet pressure to determine if the inlet 

pressure is in the range 2.75 – 7.00kPa.

 

•  

Check that the insert has been fitted correctly.

 

•  

 Check that the turret screw is fully screwed down.

 

•   

 Check that the regulator has been fitted to the gas 

supply line in the correct orientation, the arrow on 

the base of the body indicates the direction of gas 

flow.

Once these checks have been completed, if the  

regulator still fails to perform in a satisfactory manner  

it should be replaced.

9.   One by one, turn the knobs to minimum and screw 

in the bypass screw (accessible when the knob is 

removed) until a small stable flame results. Turn the 

knob to maximum and then back to minimum to ensure 

that the correct minimum flame is maintained.

10.   Attach the LPG sticker to the cooker, near the gas 

supply inlet. Cover the Natural Gas label that is 

factory fitted.

Flame size adjusted 

to maximum

Flame size adjusted 

to minimum

Bypass screw

Control knob shaft

Top hat nut assembly, 

fully screwed down

Turn top 

hat nut anti-

clockwise 

and remove

Configuration for 

Natural Gas

Configuration for LPG

A

B

C

D

E

F

G

H

34

LPG CONVERSION

35

LPG CONVERSION

Summary of Contents for WFE512 Series

Page 1: ...r living services safety notices and shop for accessories 1 Open the camera app on your smartphone and point at the QR code to scan Product Registration QR code is located on the front of your appliance or inside the door rim 2 Tap the notification or link to open the registration form 3 Complete your details and enjoy peace of mind Exact location of QR code may vary depending on oven model ...

Page 2: ...e heater In order to avoid a fire the appliance must be kept clean and vents kept unobstructed Do not spray aerosols in the vicinity of the appliance during operation Do not use or store flammable materials in or under the appliance e g Aerosols Accessible parts will become hot when in use To avoid burns and scalds children should be kept away Always use gloves when handling hot items inside grill...

Page 3: ...r Grill Oven selector Function Selector Function Selector Grill temperature selector 2 hour timer 2 hour timer 2 hour timer 2 hour timer 1 hour timer 2 hour timer 2 hour timer Oven temperature selector Oven temperature selector Grill Oven temperature selector Oven temperature selector Grill Oven temperature selector Oven temperature selector Oven temperature selector Grill Oven temperature selecto...

Page 4: ...paring for installation 1 Check that the required services are correctly positioned see electrical and gas services requirements section and cabinet requirements section 2 Ensure that cabinetry has correct details see cabinet requirements section 3 Unpack the cooker 4 Remove the foam pack containing accessories 5 Remove the internal pack from the oven and position shelf supports and grill trays 6 ...

Page 5: ... is intended to supply this cooking range Data plate gives information about rating is located behind the bottom of the oven door A functional switch operating in all active conductors MUST be provided near the appliance in an accessible position AS NZS 3000 Clause 4 7 1 Wiring MUST be protected against mechanical failure AS NZS 3000 Clause 3 9 Disconnection in the fixed wiring must occur in accor...

Page 6: ...liance test point for WFE512 WFE614 WFE612 WFE616 1 00kPa 2 60kPa Some models do not require an appliance regulator for LPG or Propane operation in which case the supply pressure and operating pressure are the same In such cases the supply pressure is adjusted at a regulator in the consumer piping typically located at the cylinder Models WFE512 WFE614 WFE612 WFE616 The following table shows the in...

Page 7: ...ect the fault if possible When maximum flame appearance is correct then check the turn down setting on each burner If the settings appear to be incorrect proceed as follows 1 Adjust the bypass screw mounted on the body of each hotplate control cock This is accessible when the control knob is removed 2 Check the ignition on all burners both separately and in combination 3 Check the operation of the...

Page 8: ...ottom is the same size as the working element We do not recommend ceramic glass pans because they do not conduct heat well Stainless steel or enamelled saucepans are best Do not use pans with copper or aluminium bottoms because they can leave traces which are difficult to remove from the glass If buying new utensils select enamelled steel pans with 2 3mm thick bottoms or stainless steel pans with ...

Page 9: ...ition For models WFG612 Turn appropriate burner control knob to maximum and at the same time press the ignition switch Flame safeguard models For models WFE614 WFE612 WFG612 WFE512 Models with flame safeguard have the same ignition procedure as above but require the knob to continue to be depressed after flame is established for approximately 5 seconds If the flame goes out when the knob is releas...

Page 10: ...ns directly on the oven base as they become very hot and will crack and craze the oven liner DO NOT use baking trays larger than 30 x 35cm 12 x 14 inches as they will restrict the circulation of the heat and may affect cooking performance of the oven Conventional Oven The shelf position is critical The temperature in centre of the oven is the temperature shown on the oven control knob Single shelf...

Page 11: ...not to touch hot surfaces Do not spray aerosols near the grill when it is turned on Do not keep flammable materials in or near the grill eg chemicals aerosols etc WARNING CAUTION Using the Grill Separate Grill Grill with door open Grill dish must be located on slides Slides must be fully pushed in while grilling Grill In Oven Grill with door closed WARNING WARNING Always clean the grill tray and g...

Page 12: ...d shelf position For sponges and cakes use aluminium bright finished or non stick utensils Oven shelf location Your oven comes with formed easy clean runners that allow five positions for shelves These are numbered from 1 the lowest shelf position to 5 the highest shelf position See diagram To give maximum space above and below the shelves load them in this way When cooking with 1 shelf use positi...

Page 13: ...e thickness or bone content of the meat MEAT RECOMMENDED TEMPERATURE MINUTES PER KG Beef 200 C Rare 35 40 Medium 45 50 Well done 55 60 Lamb 200 C Medium 40 Well done 60 Veal 180 C Well done 60 Pork 200 C Well done 60 Roasting poultry and fish Place the poultry or fish in an oven set at a moderate temperature of 180 C Place a layer of foil over the fish for about three quarters of the cooking time ...

Page 14: ...e function and appearance of your appliance Care must be taken when wiping exposed stainless steel edges as they can be sharp The front frame around the oven can be cleaned with stainless steel cleaners if it comes soiled or discoloured A suitable cleaner can be purchased from Electrolux Customer Care Centres Always clean the stainless steel in the direction of the grain Going against the grain ma...

Page 15: ...el trim rings which after initial use change colour to light brown This is a normal characteristic of stainless steel and will not affect the operation or performance of your hotplates Clean off any spillage after hot plate has cooled down At regular intervals clean hotplate with a nylon scouring pad and soapy water Wipe clean then warm hotplate for 30 seconds to dry the surface Apply hot plate pr...

Page 16: ...r Care Centre Cooker smoking when first used Protective oils being removed Turn grill on high for 30 mins and then the oven on 220 C for 1 hour Too much condensation building up when baking Too much water used when cooking Reduce amount of water Leave oven door open after cooking Smells when first using oven Protective oils being removed This is normal 120 minute timer ring not audible Timer not w...

Page 17: ...ot Care should be taken not to damage other parts of the cooker Procedure to assemble the door to be done by personnel only Procedure to assemble the door to be done by qualified personnel only 1 Hold door with both hands and locate both hinges into the frame slots at the same time Frame slot Hinge Notch 4 Close the door fully 2 Ensure that the location notch drops into the frame slot Care should ...

Page 18: ...14 AND WFE612 AND WFE616 ONLY This appliance is supplied set up for Natural Gas usage A conversion kit is included with the product for Universal LPG usage The conversion kit contains 5 injectors and 1 LPG sticker Please follow the procedure below if a conversion to suit UNIVERSAL LPG is required 1 Remove the hotplate trivets burner caps and burner crowns to access the hotplate injectors Replace t...

Page 19: ...caused by i negligence or accident ii misuse or abuse including failure to properly maintain or service iii improper negligent or faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear v power surges electrical storm damage or incorrect power supply vi incomplete or improper installation vii incorrect improper or inappropriate op...

Page 20: ...38 39 NOTES NOTES NOTES NOTES ...

Page 21: ...nformation on all Westinghouse appliances or for dimension and installation information call into your retailer phone or email our customer care team or visit our website and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used under license All Rights Reserved ANC A21384302 Rev A 2021 Electrolux Home Products Pty Ltd ABN 51 004 762 341 W_MAN_540_600_SU_Cooker_A4_Jul21 ...

Reviews: