trOuBlesHOOtinG Guide

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these 

installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be 

remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.

TROUBLE 

1. If fan does not start:

2. If fan sounds noisy: 

3. If fan wobbles:

 

4. If light does not work:

SUGGESTED REMEDY

1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #15 or #16 of installation. 
 

CautiOn:

 Make sure main power is turned off.

3. Make sure forward/reverse switch is firmly in up or down position. 
  Fan will not operate when switch is in the middle.
4. If the fan still will not start, contact a qualified electrician. 
  Do not attempt to troubleshoot internal electrical connections yourself.

1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the motor are tight.
3. Some fan motors are sensitive to signals from Solid State variable speed controls. 
  DO NOT USE a Solid State variable speed control.
4. Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear 
  after this period.

All blades are weighed and grouped by weight. Natural woods vary in density which could cause 
the fan to wobble even though all blades are weight-matched. The following procedures should 
eliminate most of the wobble. Check for wobble after each step.

1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are tightened securely to motor.
3. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.
4. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute 
the weight and possibly result in smoother operation.

1. Check to see that the wire connections in the switch housing are connected.
2. Check for faulty light bulbs.
3. If light kit will still not operate, contact a qualified electrician for assistance.

NOTICE

This ‘Energy Policy Act 2005’ compliant fan includes a device

that limits the total wattage of its light fixture to 190 watts.

By installing a combination of light bulbs that exceeds 190 watts or if an
electrical surge causes the wattage to exceed 190 watts, the light fixture

will either dim the lights to 190 watts or will automatically turn off.

To restore the light levels, make sure the total wattage of the light bulbs

does not exceed 190 watts and follow the applicable directions below:

For fans with 

Pull Chains:

Pull the light fixture’s pull chain two times to reset the light fixture.

If the power to your fan is controlled by a toggle wall switch, it may

be necessary to turn the power off and back on at the wall switch.

For fans with 

Wall Controls:

Press the light button on the wall control “off” and “on”

once to reset the light fixture.

For fans with 

Remote Controls

:

If you verify the wattage and the lights do not turn on, press the

light button on the remote control twice to reset the light fixture.

NOTE:

 If the procedures above do not reset the lights,

turn off the main power source, located at the breaker panel or box,

and then turn it on again.

Summary of Contents for UL-ES-Parkway-WH10

Page 1: ...kway WH10 Owner s Manual Manual del usuario Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia Net Weight 14 08 LBS Peso Neto 6 39 KG...

Page 2: ...tiontomotor balancingorduringcleaning Donotinsertforeignobjectbetweenrotatingblades 10 Attachthemountingbracketusingonlythehardwaresuppliedwiththeoutletbox Fanisonlytobemountedtoanoutletboxmarked Acce...

Page 3: ...sandos lolatorniller asuministradaconlacajadeembutir Elventiladors losedebemontarenunacajadeembutirmarcada AcceptableforFanSupport Aceptableparasoportarventiladores 11 ADVERTENCIA Parareducirelriesgod...

Page 4: ...rmal ceilings Para cielorrasos normales VAULTED CEILING INSTALLATION INSTALACI N PARA CIELORRASOS ABOVEDADOS May require a longer downrod sold separately Podr a requerir una varilla vertical m s larga...

Page 5: ...de NOTE Combo Blade finishes vary depending upon model ASPAS DE DOBLE CARA Lasaspasdelrotordedoblecarapresentandossuperficiesconunacabadodealtacalidad Invirtiendo lasaspaspuedeUd producirunefectodecor...

Page 6: ...an to wobble 2 pREPARING for installation Antes de la instalaci n Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas est n incluidas Apague la alimentaci...

Page 7: ...2 onthecanopy Rotatethemounting bracketandremovefromthecanopy Quitelostornillosylasdosarandelasenestrelladelosdosorificioscoincidentes 1 deldosel Afloje noquite lostornillosdelasranurascoincidentes 2...

Page 8: ...If flush mount option is selected proceed to page 9 step 6 OPCI N DE INSTALACI N AL RAS Si elige la opci n de montaje al ras proceda a la p gina 9 paso 6 NORMAL DOWNROD OPTION If installing downrod s...

Page 9: ...nillosdemontajeal rasylasarandelasdepresi nincluidas Aprietelostornillosasegur ndolos 7 2 1 Forflushmountoption raisefanassemblyandplaceontohookfrommounting bracket 2 intoaclosedholeonthecanopy 1 This...

Page 10: ...downrodyoke Installyokecrosspin 1 through yokeanddownrod Insertclamppin 2 intocrosspinuntilitsnapsintoplace Tightensetscrews 3 inyoke PROCEEDTOPAGE13 STEP13 Paseloshilosconductoresdelmotoratrav sdelav...

Page 11: ...no pre drilled hole exists in the extended downrod tighten the set screw against the downrod to secure the downrod ball Vuelva a instalar el pasador en la varilla vertical m s larga y deslice la esfer...

Page 12: ...toratrav sdelavarillavertical conjuntodeldoseleinsertelavarillaverticalenlahorquilladelamisma Aseg resedequeelorificiodelavarillavertical yeldelahorquilladelavarillaverticalest nalineados Instaleelpas...

Page 13: ...onesdecableado 13 Carefully lift fan assembly onto mounting bracket Rotate fan until notch on downrod ball 1 engages the ridge on the mounting bracket 2 This will allow for hands free wiring Levante c...

Page 14: ...hain control PULL CHAIN WIRING OPTION WALL CONTROL WIRING OPTION Siga las instrucciones del diagrama anterior para hacer las conexiones de cableado para el ventilador con control de pared Siga las ins...

Page 15: ...sel directamente abajo y en l nea con los dos tornillos del soporte de montaje 3 Eleve el dosel permitiendo que los dos tornillos y las arandelas en estrella se deslicen dentro de las ranuras Gire el...

Page 16: ...ayleng etaspl sticasdeembalajeparasosteneralmotor 1 y desc rtelas Fijeelconjuntodelaspaletasalmotorusandolasjuntasreductoras desonidodelmotor 2 ylostornillosparaelmotorincluidos Aprietelostornillos as...

Page 17: ...o de luces 2 blanco a blanco y negro a negro Conecte el artefacto luminoso al alojamiento del interruptor con los tres tornillos peque os incluidos 1 2 20 21 Light fixture installation Instalaci n del...

Page 18: ...el artefacto y ajuste la arandela de caucho metal 2 con la parte de caucho hacia el vidrio la arandela de presi n 3 y la tuerca 4 en la parte inferior de la pantalla Aseg rese de que la cadenilla de t...

Page 19: ...pling Confirm chains are held by lightly pulling both chains in coupling Sujetar las cadenas largas de tiro con las piezas finales correspondientes a las cadenas del ventilador introduciendo el extrem...

Page 20: ...illustration B This allows you to set your heating unit on a lower setting without affecting your comfort Please however refer to point 10 in SafetyTips when operating in this position NOTE Turn off...

Page 21: ...echo como lo indica la ilustraci n B Esto le permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad De todos modos por favor consulte el punto 10 de las Sugerencias de segurida...

Page 22: ...wobbleeventhoughallbladesareweight matched The following procedures should eliminate most of the wobble Check for wobble after each step 1 Check that all blades are screwed firmly into blade holders 2...

Page 23: ...iladoroscilea ncuandotodaslaspaletasest nagrupadasporpeso Lossiguientesprocedimientos deber aneliminarlamayor adelosproblemasdeoscilaci n Verifiquelaoscilaci ndespu sdecadapaso 1 Verifique que todas l...

Page 24: ...trademark of Westinghouse Electric Corporation Made in China 2010 Westinghouse Lighting Corporation Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia PA 19154 U S A Westinghouse Light...

Reviews: