1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1996), including fire-rated construction.
2. Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
3. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on 

the other side of the outlet box.

4. Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally.  When the service disconnecting 

means cannot be locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

5. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support.  And use mounting screws provided with the outlet box. 

(Mounting must support at least 35 lbs.)

9. Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.
10. Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”. 
11. To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13. NEVER place a switch where it can be reached from a tub or shower.
14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as 

those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15. Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally.  When the service disconnecting means 

cannot be locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

SAFETY TIPS

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT", 

AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES 

ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

TOOLS REQUIRED

Phillips Screwdriver         Wire Cutters         Pliers        Step Ladder

UL_TurboSwirl  1/18/05  12:15 PM  Page 2

Summary of Contents for Turbo Swirl

Page 1: ...R S MANUAL MANUAL DEL USUARIO MR N W 5 2 KGS G W 5 7 KGS Turbo SwirlTM Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia UL_TurboSwi...

Page 2: ...cing or during cleaning Do not insert foreign object between rotating blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box Fan is only to be mounted to an outlet...

Page 3: ...ndo s lo la torniller a suministrada con la caja de embutir El ventilador s lo se debe montar en una caja de embutir marcada Acceptable for Fan Support Aceptable para soportar ventiladores 11 Para red...

Page 4: ...cielorrasos normales VAULTED CEILING INSTALLATION INSTALACI N PARA CIELORRASOS ABOVEDADOS May require a longer downrod sold separately Podr a requerir una varilla vertical m s larga se vende por sepa...

Page 5: ...ARING FOR INSTALLATION ANTES DE LA INSTALACI N Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas est n incluidas Apague la alimentaci n en la caja de fu...

Page 6: ...ating slots 2 on the canopy Rotate the mounting bracket counter clockwise and remove from the canopy Quite los tornillos y las dos arandelas en estrella de los dos orificios coincidentes 1 del dosel A...

Page 7: ...option is selected proceed to page 8 step 6 OPCI N DE INSTALACI N AL RAS Si elige la opci n de montaje al ras proceda a la p gina 8 paso 6 NORMAL DOWNROD OPTION If installing downrod supplied with fa...

Page 8: ...e al ras y las arandelas de presi n incluidas Apriete los tornillos asegur ndolos 7 For flush mount option raise fan assembly and place onto hook from mounting bracket into a closed hole on the canopy...

Page 9: ...de la varilla vertical y el de la horquilla de la varilla vertical est n alineados Instale el pasador transversal de la horquilla 1 pas ndolo por la horquilla y la varilla vertical Inserte el pasador...

Page 10: ...drilled hole exists in the extended downrod tighten the set screw against the downrod to secure the downrod ball Vuelva a instalar el pasador en la varilla vertical m s larga y deslice la esfera de la...

Page 11: ...rtical conjunto del dosel e inserte la varilla vertical en la horquilla de la misma Aseg rese de que el orificio de la varilla vertical y el de la horquilla de la varilla vertical est n alineados Inst...

Page 12: ...e cableado 13 1 2 Carefully lift fan assembly onto mounting bracket Rotate fan until notch on downrod ball 1 engages the ridge on the mounting bracket 2 This will allow for hands free wiring Levante c...

Page 13: ...om n Negro vivo Azul vivo Principal tierra Blanco com n Interruptor del ventilador vivo Interruptor de la luz vivo Verde de tierra Del Ventilador De La Casa conectar conectar conectar conectar Conecte...

Page 14: ...tiendo que los dos tornillos y las arandelas en estrella se deslicen dentro de las ranuras Gire el dosel en sentido horario hasta que ambos tornillos del soporte de montaje caigan adentro de las ranur...

Page 15: ...o a trav s de los soportes para paletas luego a trav s de las almohadillas recuadro A Las almohadillas sostendr n los tornillos del motor en su sitio durante la instalaci n Fije el conjunto de las pal...

Page 16: ...of the glass Pull the glass shade toward the third spring clip Push the third clip to fit inside the glass and push the glass up into the fitter Fije la pantalla al artefacto insertando el cuello de...

Page 17: ...are held by lightly pulling both chains in coupling Sujetar las cadenas largas de tiro con las piezas finales correspondientes a las cadenas del ventilador introduciendo el extremo de la cadena larga...

Page 18: ...to set your heating unit on a lower setting without affecting your comfort Please however refer to point 10 in Safety Tips when operating in this position NOTE Turn off and wait for fan to stop befor...

Page 19: ...o le permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad De todos modos por favor consulte el punto 10 de las Sugerencias de seguri dad cuando utilice el ventilador en esta...

Page 20: ...e speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period All blades are weighed and g...

Page 21: ...NO USE un control de velocidad variable de estado s lido 5 Permita el rodaje del ventilador durante un per odo de 24 horas La mayor a de los ruidos asociados con el ventilador nuevo desaparecer n desp...

Page 22: ...22 UL ES TurboSwirl WH05 UL_TurboSwirl 1 18 05 12 15 PM Page 22...

Page 23: ...n Speed Switch 6 Light Control Switch 7 Capacitor 8 Hardware Pack No Descripci n 1 Soporte de montaje 2 Soporte para paleta 3 Paleta 4 Pantalla de vidrio 5 Interruptor de control de velocidad para ven...

Page 24: ...inghouse Electric Corporation Made in China 2005 Westinghouse Lighting Corporation Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia PA 19154 U S A Westinghouse Lighting Corporation ti...