TYPES I R P , IRC AND I R D R E L AYS.
AMPERE
RANGE
0 . 5/ 2 . 5
2/6
4/ 1 2
TAP
(0.5
(0.6
( 0 . 8
( 1 . 0
( 1 . 5
(2.0
( 2 . 5
(2
(2.5
( 3
( 3 . 5
( 4
( 5
( 6
( 4
( 5
(6
(7
( 8
( 10
( 1 2
AMPERE
E NE RG Y REQUI R EME NTS
I R D-8, I RC-8, I RP · 8 ,
T I M E O V E RC U R R E N T U N IT S
I R D-9, I RC-9, I RP -9,
VOLT AMPERE S
tt
*
CONTINUOUS
RATING
(AMPERES)
2
2 . 2
2 . 5
2 . 8
3 .4
4 .0
4 .4
8
8.8
9 . 7
1 0 . 4
1 1 . 2
1 2 . 5
1 3 . 7
1 6
1 8 . 8
1 9 . 3
20.8
22.5
25
28
ONE SECOND
POWER
RATING
t *
FACTOR
(AMPERES)
ANGLE
¢
88
88
88
88
88
88
88
230
230
230
230
230
230
230
460
460
460
460
460
460
460
72
71
69
67
62
57
53
70
66
64
62
60
58
5 6
68
63
60
57
54
48
45
AT
TAP VALUE
CURRENT
2 . 3 8
2 . 38
2.40
2.42
2 . 5 1
2 . 65
2.74
2.38
2 . 4 0
2 . 4 2
2 . 4 8
2 .53
2.64
2 . 75
2 . 3 8
2.46
2 . 54
2 . 6 2
2 . 7 3
3 .00
3 .46
AT 3 TIMES
TAP VALUE
CURRENT
2 1
2 1
2 1 . 1
2 1 . 2
22
23 . 5
2 4 . 8
2 1
2 1 . 1
2 1 . 5
2 2
2 2 . 7
24
2 5 . 2
2 1 . 3
2 1 . 8
2 2 . 6
2 3 . 6
24. 8
2 7 . 8
3 1 .4
AT
10
TIMES
TAP VAL UE
CURRENT
1 3 2
134
142
150
170
200
228
1 3 6
1 4 2
1 4 9
1 5 7
1 6 4
180
198
146
158
172
190
207
248
292
I R D- 1 1 , IRC-1 1 , I R P- 1 1 OVE RCUR R ENT UNITS
ONE SECOND
POWER
AT
RATING t
*
FACTOR TAP VALUE
VOLT AMPEREStt
*
AT
20
TIMES
TAP VALUE
CURRENT
350
365
400
440
530
675
800
360
395
430
470
500
580
660
420
480
550
620
700
850
1020
RANGE
TAP
CONTINUOUS
RATING
.�MPERES)
(AMPERES)
ANGLE <;\
CURRENT
AT
3
TIMES
TAP VALUE
CURRENT
AT
10
TIMES
TAP VALUE
CURRENT
AT
20
TIMES
TAP VALUE
CURRENT
0.5/2.5
2/6
4 / 1 2
0.5
0.6
0.8
1 .0
1 . 5
2.0
2 . 5
2 . 0
2 . 5
3 . 0
3.5
4.0
5.0
6.0
4.0
5.0
6.0
7.0
8.0
10.0
1 2 .0
1 .7
1 . 9
2.2
2.5
3.0
3.5
3.8
7.0
7.8
8.3
9.0
1 0.0
1 1 .0
1 2.0
14
16
17
18
20
22
26
56
56
56
56
56
56
56
230
230
230
230
230
230
230
460
460
460
460
460
460
460
36
34
30
27
22
1 7
1 6
32
30
27
24
23
20
20
29
25
22
20
18
17
16
0.72
0.75
0.81
0.89
1.13
1 .30
1 .48
0.73
0.78
0.83
0.88
0.96
1 .07
1 .23
0.79
0.89
1 .02
1 . 10
1 .23
1 .32
1.8
6 .54
6 . 80
7.46
8.30
10.04
1 1 .95
13 .95
6.30
7.00
7.74
8.20
9.12
9.80
1 1 .34
7 .08
8.00
9.18
10.00
1 1 . 1
14.9
16.3
7 1 .8
75.0
84.0
93.1
115.5
136.3
160.0
74.0
78.5
84 . 0
89.0
102.0
109.0
129.0
78.4
90.0
101.4
11.0.0
124.8
1 3 1 .6
180.0
250
267
298
330
4 1 1
502
6 1 0
264
285
309
340
3?2
430
504
296
340
378
454
480
600
720
*
t
Thermal capacities for s hort times other than one se cond may be c alculated on the basis of time being inversely
proportional to the s quare of the c urrent.
¢ Degrees c urrent lags voltage at tap value c urrent.
'If< tt
Voltages taken with R e ctox type voltmeter.
1 1