background image

2

ETL-ES-GW-Industrial Look-WJ-WH20.03

1.  Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.

2.  Use this unit only in the manner intended by the manufacturer.  If you have  any  questions contact the manufacturer.

3.  After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on 

 

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

4.  Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.  When the service disconnecting means cannot be 

 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

5.  Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.  Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8.  To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must 

 

support at least 35 lbs.)

9.  WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10.  Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”. 

11.  WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12.  If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13.  NEVER place a switch where it can be reached from a tub or shower.

14.  The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those 

 

published by the National Fire Protection Association (NFPA),  and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15.  Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.  When the service disconnecting means cannot be 

 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

16.  All set screws must be checked and re-tightened where necessary before installation.

17.    The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance.

TOOLS REQUIRED

Phillips Screwdriver         Wire Cutters         Pliers        Step Ladder

SAFETY TIPS

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED 'ACCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS' 

AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE. MOST OUTLET BOXES COMMONLY USED FOR THE 

SUPPORT OF LUMINARIES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

Summary of Contents for 7840900

Page 1: ...rial Look WJ WH20 03 OWNER S MANUAL MANUAL DEL USUARIO Please write model number here for future reference Por favor incluya el número del modelo aquí para futura referencia Net Weight LBS Peso Neto KGS Industrial Look ...

Page 2: ...untingbracketusingonlythehardwaresuppliedwiththeoutletbox Fanisonlytobemountedtoanoutletboxmarked AcceptableforFanSupport 11 WARNING Toreducetheriskoffireorelectricshock donotusethisfanwithanysolidstatefanspeedcontroldevice orvariablespeedcontrol 12 Ifthisunitistobeinstalledoveratuborshower itmustbemarkedasappropriatefortheapplication 13 NEVERplaceaswitchwhereitcanbereachedfromatuborshower 14 Thec...

Page 3: ...cada AcceptableforFanSupport Aceptableparasoportarventiladores 11 ADVERTENCIA Parareducirelriesgodeincendiosochoqueseléctricos nouseesteventiladorconundispositivodecontroldevelocidaddeestadosólidoparaventilador ouncontroldevelocidadvariable 12 Siestaunidadseinstalarásobreunabañeraounaducha debeestaridentificadacomoadecuadaparaesetipodeaplicación 13 NUNCAcoloqueuninterruptordondesepuedaalcanzardesd...

Page 4: ...cause the fan to wobble 2 PREPARING FOR INSTALLATION ANTES DE LA INSTALACIÓN Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas estén incluidas Apague la alimentación en la caja de fusibles para evitar la posibilidad de descarga eléctrica Use una caja de embutir de metal adecuada para soportar un ventilador debe soportar 35 libras Antes de fijar el ve...

Page 5: ... Install J hook mounting plate to outlet box in ceiling using the screws provided with the outlet box 3 Instale la placa de montaje del gancho J a la caja de embutir del techo con la tornillería suministrada para la caja de embutir ETL ES GW Industrial Look WJ WH20 03 ...

Page 6: ...switch hole in the lower canopy Slide the lower canopy down make sure there is at least 1 4 clearance maintained between the motor and lower canopy bottom and position the reverse switch prop erly Tighten set screw in the lower canopy 4 Alineeelinterruptordemarchaatrásdelahorquillaalagujeroparaelinterruptordemarcha atráscorrespondienteubicadoeneldoselinferior Desliceeldoselinferiorhaciaabajo asegú...

Page 7: ...onectar conectar conectar conectar Conecte el cable azul sólo si conecta un juego de luces al ventilador Control de pared Siga las instrucciones del diagrama anterior para hacer las conexiones de cableado para el ventilador con control de pared OPCIÓN DE CABLEADO PARA CONTROL DE PARED 7 MOUNTING MONTAJE After wiring is complete gently push wires into junction box with wire nuts pointed upward Una ...

Page 8: ...crews and washers See above drawing for reference 9 Instale las aletas en la parte superior del motor con la tornillería Utilice la ilustración anterior como referencia SECURE TO CEILING ASEGUREELVENTILADORALTECHO 3 Slide top canopy up and tighten set screw s 8 Deslice el dosel superior y ajuste el los tornillo s de fijación ...

Page 9: ...8 Terminal Box 9 Terminal Box Screw 10 Black Supply Lead Wire 11 Black Fan Lead Wire 12 Ground Lead Wire Piezas 1 Caja de embutir 2 Tornillos de la barra transversal 3 Barra transversal 4 Tornillos de la caja de embutir 5 Unidad de control 6 Panel delantero 7 Tornillo del panel delantero 8 Caja de terminales 9 Tornillo de la caja de terminales 10 Cable guía negro de alimentación 11 Cable guía negr...

Page 10: ... cableado del control de pared A Quite los tornillos de la barra transversal 2 del control de pared y fije la barra transversal 3 a la caja de embutir B Quite el tornillo del panel delantero 7 Lo necesitará en el paso E Quite la cubierta delantera 6 ADVERTENCIA TENGA MUCHO CUIDADO AL QUITAR LA CUBIERTA DE LA PLACA DELANTERA C Conecte el cable guía negro de alimentación 10 en la posición A el cable...

Page 11: ...osition Reverse Fan turns clockwise direction An upward airflow moves warm air off the ceiling area as shown in illustration B This allows you to set your heating unit on a lower setting without affecting your comfort NOTE Turn off and wait for fan to stop before changing the setting of the forward reverse slide switch Maintenance 1 Because of the fan s natural movement some connections may become...

Page 12: ...d Clima frío posición hacia arriba Atrás El ventilador gira en sentido de las agujas del reloj Una corriente de aire ascendente aleja el aire caliente del área del ventilador de techo como lo indica la ilustración B Esto le permite ajustar la calefacción a un nivel más bajo sin que afecte su comodidad NOTA Apague el ventilador y espere a que se detenga antes de cambiar la dirección de adelante atr...

Page 13: ...qualified electrician Do not attempt to troubleshoot internal electrical connections yourself 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade to the motor are tight 3 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 4 Allow break i...

Page 14: ...nes eléctricas internas 1 Compruebe para asegurarse de que todos los tornillos del alojamiento del motor estén ajustados no los apriete demasiado 2 Compruebe para asegurarse de que los tornillos que fijan el soporte de la aleta del ventilador al motor estén apretados 3 Algunos motores de ventilador son sensibles a las señales de los controles de velocidad variable de estado sólido para motores NO ...

Page 15: ...g com contact us Este ventilador deWestinghouse Lighting se ofrece con una garantía de 15 años al comprador original frente a defectos de material y de mano de obra Esta garantía sustituye cualquier otra garantía expresa o implícita Westinghouse Lighting reparará o reemplazará las piezas necesarias y o reemplazará el ventilador de techo si el fallo se debe a defectos de material o de mano de obra ...

Page 16: ...W Industrial Look WJ WH20 03 1 2 3 Description 1 Mounting Bracket 2 Blade 3 Wall Control 4 Hardware Pack No Descripción 1 Soporte de montaje 2 Aleta 3 Control de pared 4 Tornillería 4 PARTS LIST LISTA DE REPUESTOS ...

Page 17: ...17 ETL ES GW Industrial Look WJ WH20 03 ...

Page 18: ...18 ETL ES GW Industrial Look WJ WH20 03 ...

Page 19: ...19 ETL ES GW Industrial Look WJ WH20 03 ...

Page 20: ...e Lighting Philadelphia PA 19154 1029 U S A www westinghouselighting com WESTINGHOUSE and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation Used under license by Westinghouse Lighting All rights reserved Made in China ...

Reviews: