background image

2

SAA-Urban Gale-Australia-WH18

1.  Proceed with caution. Read all instructions before beginning the installation.

2.  Only an authorized electrician should execute the installation.

3.  The installation height, i.e. the distance between the blades and the floor, should be at least 2.3 m.

4.                   Always maintain the distance between the lamp and inflammable materials (curtains, wall, etc.), as indicated on the pictogram.

5.  Make sure the fan is securely fastened at the ceiling.

6.  WARNING! Do not use a dimmer type switch to control the fan speed.

7.  WARNING! To prevent injuries, make sure the blades are not bent and that there are no objects with in the area of rotation.

8.  WARNING! Due to European safety regulations, if the flush mount option is elected, the fan must not be re-installed utilizing the downrod. 

        If attempted, this may cause a serious injury. When assembling the fan, please follow your local safety regulations.

9.  WARNING: Do Not use this fan in the same room at the same time as a gas or fuel burning fire, unless the flue has been tested under these conditions of use by a competent person.

10.  This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been 

        given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user mainte

        nance shall not be made by children without supervision.

11.  Suitable for use indoors.

12.  Before disassembling light kit, make sure the power supply is disconnected from the main supply. Power supply can be on only after installation is completed.

13.  The lampshade should not be removed from the light bulb when the power supply is on. 

14.  Replacement of light bulb is only possible when the light kit has cooled down, and the power supply is disconnected from the main supply.

15.  Make sure the lampshade is in the fixed position when operating the product.

16.  Means for all poles disconnection having a contact separation that provide full disconnection under over voltage category III conditions must be incorporated in the fixed wiring in 

        accordance with national wiring rules.

17.  IP20 The fan is designed for indoor use. It is not designed for installation in a bathroom or any damp area. Please ensure that the lamp does not come into contact with water.

18.  WARNING: If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons. 

19.  The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.

20.  The fixing means for attachment to the ceiling can be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.

21.  The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

TOOLS REQUIRED

Phillips Screwdriver         Wire Cutters         Pliers        Step ladder

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

READ AND SAVE THESE INSTRUCTIONS

SAfETy TIpS

Summary of Contents for 7202135

Page 1: ...SAA Urban Gale Australia WH18 Owner s Manual Urban Gale Please write model number here for future reference 7202135 NetWeight 5 0 KGS 240V 50Hz ...

Page 2: ... 11 Suitable for use indoors 12 Before disassembling light kit make sure the power supply is disconnected from the main supply Power supply can be on only after installation is completed 13 The lampshade should not be removed from the light bulb when the power supply is on 14 Replacement of light bulb is only possible when the light kit has cooled down and the power supply is disconnected from the...

Page 3: ...3 SAA Urban Gale Australia WH18 Features For normal ceilings DOWNROD INSTALLATION May require a longer downrod sold separately VAULTED CEILING INSTALLATION ...

Page 4: ...er at fuse box to avoid possible electrical shock 1 pREPARING for installation Use metal outlet box suitable for fan support must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble 2 ...

Page 5: ...ng bracket to outlet box in ceiling using the screws and wash ers provided with the outlet box WIRING OPTIONS 4 Follow diagram above to make wiring connections to the terminal block on the mounting bracket To Connector Fan Live L Neutral N Ground From House TERMINAL BLOCK Wiring ...

Page 6: ...ale female plug connection 1 from the fan to the terminal block Attach the ground wire 2 from the downrod to the mounting bracket 5 Carefullyliftfanassemblyontomountingbracket Rotatefanuntilnotchondown rodball 1 engagestheridgeonthemountingbracket 2 This willallowforhands freewiring 2 2 1 1 ...

Page 7: ...tion both slots on canopy directly under and in line with two screws in the mounting bracket 3 Lift the canopy allowing the two screws to slide into the mating slots Rotate the canopy until both screws from the mounting bracket drop into the slot recesses Tighten screws securely Install two screws into the mating holes of the canopy and tighten to secure the canopy to the mounting bracket ...

Page 8: ...8 Loosen set screw in lower canopy and slide to within 1 4 7mm of the motor Tighten set screw s in the lower canopy Make sure there is at least 1 4 7mm clearance maintained around the motor and lower canopy PREPARING FOR INSTALLATION ...

Page 9: ...Australia WH18 Blade Installation Install blades to top of motor using screws and washers See above drawing for reference 9 10 Attach blade brackets to blades using the blade bracket screws 1 metal washers 2 and nuts 3 ...

Page 10: ...10 SAA Urban Gale Australia WH18 Remove the front cover of the wall control by unsnapping the cover 1 from the control unit 2 1 2 OFF OFF 11 WALL CONTROL INSTALLATION ...

Page 11: ...ntrol wire from the fan to the terminal block on the wire marked For fan L as line art shown on 1 Connect the 240V hot house wire to the terminal block on the wire marked TO AC L240V 50HZ as line art shown on 2 2 1 1 OFF 2 12 Wiring to the wall control ...

Page 12: ...m the terminal connections on the back of the fan control unit Push wiring back into wall outlet box and secure the wall outlet unit 1 to the outlet box 2 with screws provided 14 OFF 2 OFF 1 Install wall control to outlet box Operation Fan Rotary Control OFF Fan Speed OFF 3 Fan Speed HIGH 2 Fan Speed MEDIUM 1 Fan Speed LOW ...

Page 13: ...13 SAA Urban Gale Australia WH18 Replace the front cover of the wall control unit by snapping the cover 1 onto the control unit 2 15 OFF OFF 1 2 Install wall control to outlet box ...

Page 14: ...eck to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 4 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period...

Page 15: ...15 SAA Urban Gale Australia WH18 PARTS LIST Description 1 Mounting Bracket 2 Blade Bracket 3 Blade 4 Wall Control 5 Capacitor 6 Hardware Pack 6 5 4 2 3 1 OFF ...

Page 16: ...hia PA 1029 19154 U S A www westinghouselighting com WESTINGHOUSE and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation Used under license by Westinghouse Lighting All rights reserved Made in China AS NZS Approval No SAA 181731 EA ...